• EN 60517:1996/A11:1999

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES OF 72,5 KV AND ABOVE

    Available format(s): 

    Superseded date:  27-02-2004

    Language(s): 

    Published date:  12-01-2013

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normal and special service conditions
    3 Definitions
    4 Rating
    4.1 Rated voltage
    4.2 Rated insulation level
    4.3 Rated frequency
    4.4 Rated normal current and temperature rise
    4.5 Rated short-time withstand current
    4.6 Rated peak withstand current
    4.7 Rated duration of short-circuit
    4.8 Rated supply voltage of closing and opening
           devices and auxiliary circuits
    4.9 Rated supply frequency of operating devices and
           auxiliary circuits
    4.10 Rated pressure of compressed gas supply for
           operating mechanisms
    4.101 Rated density of gas for insulation
    5 Design and construction
    5.1 Requirements for liquids in switchgear and
           controlgear
    5.2 Requirements for gases in switchgear and
           controlgear
    5.3 Earthing
    5.4 Auxiliary equipment
    5.5 Dependent power closing
    5.6 Stored energy closing
    5.7 Operation of releases
    5.8 Low and high pressure interlocking devices
    5.9 Nameplates
    5.101 Degree of protection
    5.102 Internal fault
    5.103 Enclosures
    5.104 Partitions
    5.105 Pressure relief
    5.106 Disconnectors and earthing switches
    5.107 Interlocks
    5.108 Noise
    5.109 Provisions for dielectric tests on cables
    6 Type tests
    6.1 Dielectric tests
    6.2 Radio interference voltage (RIV) tests
    6.3 Temperature-rise tests
    6.4 Measurement of the resistance of the main circuit
    6.5 Short-time and peak withstand current tests
    6.101 Verification of making and breaking capacities
    6.102 Mechanical operation tests
    6.103 Verification of the degree of protection for
           auxiliary circuits and moving parts
    6.104 Proof tests for enclosures
    6.105 Weatherproofing test
    6.106 Test under conditions of arcing due to an
           internal fault
    6.107 Thermal stability test
    6.108 Operation tests at limit temperatures
    6.109 Gas tightness tests
    7 Routine tests
    7.1 Power-frequency voltage tests on the main circuit
    7.2 Dielectric tests on auxiliary and control
           circuits
    7.3 Measurement of the resistance of the main circuit
    7.101 Partial discharge measurement
    7.102 Pressure tests of enclosures
    7.103 Gas tightness tests
    7.104 Mechanical operation tests
    7.105 Tests of auxiliary electrical, pneumatic and
           hydraulic devices
    7.106 Verification of the correct wiring
    7.107 Tests after erection on site
    8 Guide to the selection of the switchgear for
           service
    9 Information to be given with enquiries, tenders
           and orders
    9.101 Information with enquiries and orders
    9.102 Information with tenders
    10 Rules for transport, storage, erection and
           maintenance
    10.1 Conditions during transport, storage and
           erection
    10.2 Erection
    10.3 Maintenance
    Annex BB (normative) Methods for testing gas-insulated
             metal-enclosed switchgear under conditions
             or arcing due to an internal fault
    Annex CC (informative) Technical and practical considerations
             of site testing
    Annex ZA (informative) A-deviations
    Annex ZB (normative) Normative references to international
             publications with their corresponding European
             publications
    Figure 1

    Abstract - (Show below) - (Hide below)

    Gives requirements for gas-insulated metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure, for alternating current of voltages of 72,5 kV and above, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. The term 'switchgear' is used for gas-insulated metal-enclosed switchgear. The gas-insulated metal-enclosed switchgear consists of individual components directly connected together and able to operate only in this manner. Completes and amends the relevant standards applying to the individual components constituting gas-insulated metal-enclosed switchgear.

    General Product Information - (Show below) - (Hide below)

    Committee TC 17AC
    Development Note Supersedes HD 358 S3:1992 (11/2000)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 60298:1996 A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    DIN EN 45510-2-7:2003-12 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    HD 637 S1:1999/corrigendum:2005 POWER INSTALLATIONS EXCEEDING 1 KV A.C.
    BS EN 45510-2-7:2002 Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear
    CEI UNI EN 45510-2-7 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    BS EN 62271-2:2003 High-voltage switchgear and controlgear Seismic qualification for rated voltages of 72,5 kV and above
    UNI CEI EN 45510-2-7 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    I.S. EN 62271-2:2003 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE
    I.S. EN 45510-2-7:2002 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    EN 45510-2-7:2002 Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear
    I.S. EN 62271-102:2005 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001 (EQV))
    I.S. HD 637:1999 POWER INSTALLATIONS EXCEEDING 1 KV A.C.
    EN 62271-2:2003 High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective