• HD 632 : 1998

    Current The latest, up-to-date edition.

    POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)

    Available format(s): 

    Language(s): 

    Published date:  26-03-1998

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    PART 1 Test methods and requirements
    PART 2 Additional test methods
    PART 3 Test requirements for cables with XLPE insulation and
           metallic screen and their accessories
         3-D Cables with XLPE insulation and copper screen
             and their accessories (Test list 3D)
         3-K Cables with XLPE insulation and copper screen
             and their accessories (Test list 3K)
         3-L Cables with XLPE insulation and metallic screen
             and their accessories (Test list 3L)
         3-M Cables with XLPE insulation, copper screen and
             their accessories (Test list 3M)
         3-N Cables with XLPE insulation and copper screen and
             their accessories (Test list 3N)
    PART 4 Test requirements for cables with XLPE insulation,
           metallic screen and metal-laminated sheath and their
           accessories
         4-A Cables with XLPE insulation and polyolefine compound
             sheath (Types 1, 2 and 3)(Test list 4A)
         4-C Cables with XLPE insulation, copper or aluminium
             wires screen and aluminium or copper laminated
             sheath and their accessories (Test list 4C)
         4-D Cables with XLPE insulation, copper screen and
             aluminium-laminated sheath and their accessories
             (Test list 4D)
         4-F Cables with XLPE insulation, copper screen and
             aluminium-laminated sheath and their accessories
             (Test list 4F)
         4-G Cables with XLPE insulation and metal- laminated
             screen and their accessories (Test list 4G)
         4-K Cables with XLPE insulation, copper screen and
             aluminium-laminated sheath and their accessories
             (Test list 4K)
         4-L Cables with XLPE insulation, copper screen and
             aluminium-laminated sheath and their accessories
             (Test list 4L)
         4-M Cables with XLPE insulation, copper screen and
             aluminium-laminated sheath and their accessories
             (Test list 4M)
         4-O Cables with XLPE insulation, copper or aluminium
             screen and copper or aluminium laminated sheath
             and their accessories (Test list 4O)
         4-P Cables with XLPE insulation, copper screen and
             metal-laminated sheath and their accessories (Test list 4P)
    PART 5 Test requirements for cables with XLPE insulation and
           metallic sheath and their accessories
         5-C Cables with XLPE insulation and lead or lead alloy
             sheath, or aluminium or copper sheath and their
             accessories (Test list 5C)
         5-D Cables with XLPE insulation and metallic sheath and
             their accessories (Test list 5D)
         5-F Cables with XLPE insulation and lead or lead alloy
             sheath and their accessories (Test list 5F)
         5-G Cables with XLPE insulation and lead sheath and their
             accessories (Test list 5G)
         5-H Cables with XLPE insulation and metallic sheath and
             their accessories (Test list 5H)
         5-K Cables with XLPE insulation and lead sheath and their
             accessories (Test list 5K)
         5-L Cables with XLPE insulation and metallic sheath and
             their accessories (Test list 5L)
         5-M Cables with XLPE insulation and metallic sheath and
             their accessories (Test list 5M)
         5-O Cables with XLPE insulation and metallic sheath and
             their accessories (Test list 5O)
         5-P Cables with XLPE insulation and lead alloy sheath and
             their accessories (Test list 5P)
    PART 6 Test requirements for cables with EPR insulation and
           metallic screen and their accessories
         6-A Cables with HEPR insulation and polyolefine compound
             sheath (Types 1, 2 and 3) (Test list 6A)
         6-J Cables with HEPR insulation and copper screen and their
             accessories (Test list 6J)
         6-O Cables with EPR insulation and copper or aluminium screen
             and their accessories (Test list 6O)
    PART 7 Test requirements for cables with EPR insulation,
           metallic screen and metal-laminated sheath and their
           accessories
         7-O Cables with EPR insulation, copper or aluminium screen
             and copper or aluminium-laminated sheath and their
             accessories (Test list 7O)
    PART 8 Test requirements for cables with EPR insulation and
           metallic sheath and their accessories
         8-J Cables with HEPR insulation and metallic sheath and
             their accessories (Test list 8J)
         8-O Cables with EPR insulation and metallic sheath and their
             accessories (Test list 8O)
    PART 9 (Spare)
    PART 10 Test requirements for cables with PE or HDPE insulation,
            metallic screen and metal-laminated sheath and their
            accessories
         10-G Cables with PE or HDPE insulation and metal-laminated
              screen and their accessories (Test list 10G)
    PART 11 Test requirements for cables with PE or HDPE insulation
            and metallic sheath and their accessories
         11-G Cables with PE or HDPE insulation and lead sheath
              and their accessories (Test list 11G)

    Abstract - (Show below) - (Hide below)

    Describes test requirements for power cables with extruded insulation, of the types listed in Table 1, and their accessories, of rated voltage, U, above 36 kV (U[m] = 42 kV) up to and including 150 kV (U[m] = 170 kV), for fixed installations intended for transmission and distribution systems, and for use in power generating plants and sub-stations.

    General Product Information - (Show below) - (Hide below)

    Committee TC 20
    Development Note Supersedes UNE HD 632-0 & UNE HD 632-1. (01/2012)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
    HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
    CEI EN 50299-2 : 2016 OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS
    UNE 211632-4A:2017 Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 4A: Cables with XLPE insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath.
    UNE-EN 50299-2:2015 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations
    DIN VDE 0276-633 : 1999 TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV)
    BS 7970:2012 Electric cables. Metal foil and longitudinally welded aluminium sheath constructions of power cables having XLPE insulation for rated voltages from 66 kV (Um = 72.5 kV) to 132 kV (Um = 145 kV)
    BS 7912(2012) : 2012 POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV)
    VDE 0276-633 : 1999 TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV)
    12/30244367 DC : 0 BS 7912 - POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV)
    12/30244364 DC : 0 BS 7970 - ELECTRIC CABLES - METAL FOIL AND LONGITUDINALLY WELDED ALUMINIUM SHEATH CONSTRUCTIONS OF POWER CABLES HAVING XLPE INSULATION FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV)
    BS EN 50299-2:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Dry-type cable terminations
    CEI EN 50299-1 : 2016 OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 1: FLUID-FILLED CABLE TERMINATIONS
    BS EN 50299-1:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Fluid-filled cable terminations
    UNE-EN 50299-1:2015 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 1: Fluid-filled cable terminations
    UNE 211632-1:2017 Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 1: Requirements and test methods
    I.S. EN 50299-2:2014 OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS
    I.S. HD 620:2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
    UNE 211632-6A:2017 Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 6A: Cables with HEPR insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath.
    13/30281716 DC : 0 BS EN 50299-2 - OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS
    I.S. EN 50299-1:2014 OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 1: FLUID-FILLED CABLE TERMINATIONS
    CEI 20-56 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO
    EN 50299-1:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 1: Fluid-filled cable terminations
    EN 50299-2:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations
    UNE-HD 620.1:2010 Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 1: General requirements.
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective