• I.S. EN IEC 62271-100:2021

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers (IEC 62271-100:2021)

    Available format(s):  Hardcopy, PDF

    Superseded date:  24-02-2022

    Language(s):  English

    Published date:  13-09-2021

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Normal and special service conditions
    5 Ratings
    6 Design and construction
    7 Type tests
    8 Routine tests
    9 Guide to the selection of switchgear and controlgear (informative)
    10 Information to be given with enquiries, tenders and orders (informative)
    11 Transport, storage, installation, operation instructions and maintenance
    12 Safety
    13 Influence of the product on the environment
    Annex A (normative) Calculation of TRVs for short-line faults from rated
    characteristics
    Annex B (normative) Tolerances on test quantities during type tests
    Annex C (normative) Records and reports of type tests
    Annex D (normative) Method of determination of the prospective TRV
    Annex E (normative) Methods of determining prospective TRV waves
    Annex F (informative) Requirements for breaking of transformer-limited faults by
    circuit-breakers with rated voltage higher than 1 kV
    Annex G (normative) Use of mechanical characteristics and related requirements
    Annex H (normative) Requirements for making and breaking test procedures for
    metal-enclosed and dead tank circuit-breakers
    Annex I (normative) Requirements for circuit-breakers with opening resistors
    Annex J (normative) Verification of capacitive current breaking in presence of single
    or two-phase earth faults
    Bibliography

    Abstract - (Show below) - (Hide below)

    This part of IEC 62271 is applicable to three-phase AC circuit-breakers designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and/or 60 Hz on systems having voltages above 1 000 V.

    General Product Information - (Show below) - (Hide below)

    Committee TC 17
    Document Type Standard
    Product Note The date of any NSAIprevious adoption may not matchthe date of its original CEN/CENELEC document. This Standard Also Refers to IEC 62271-37-013
    Publisher National Standards Authority of Ireland
    Status Superseded