• IEC 60076-21:2011

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Power transformers - Part 21: Standard requirements, terminology, and test code for step-voltage regulators

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  31-12-2021

    Language(s):  English

    Published date:  15-12-2011

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. Overview
    2. Normative references
    3. Definitions
    4. Service conditions
    5. Rating data
    6. Construction
    7. Other requirements
    8. Test code
    9. Control systems
    Annex A (informative) - Unusual temperature and altitude
            conditions
    Annex B (informative) - Field dielectric tests
    Annex C (informative) - Bibliography
    Annex D (informative) - IEEE List of Participants

    Abstract - (Show below) - (Hide below)

    IEC 60076-21:2011/IEEE Std C57.15:2009 - Description of design types, tables of 50 Hz and 60 Hz ratings, supplementary ratings, construction, and available accessories are provided. Methods for performing routine and design tests applicable to liquid-immersed single and three-phase step-voltage regulators are described. Winding resistance measurements, polarity tests, insulation power factor and resistance tests, ratio tests, no load loss and excitation current measurements, impedance and load loss measurements, dielectric tests, temperature tests, routine and design impulse tests, short-circuit tests, control tests, calculated data, and certified test data are covered.

    General Product Information - (Show below) - (Hide below)

    Development Note Also numbered as IEEE C57.15. (12/2011)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    13/30265253 DC : 0 BS EN 60214-1 ED 2 - TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS
    BS EN 60214-1:2014 Tap-changers Performance requirements and test methods
    NF EN 60214-1 : 2015 TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS
    IEC 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods
    UNE-EN 60214-1:2015 Tap-changers - Part 1: Performance requirements and test methods
    I.S. EN 60214-1:2014 TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS
    EN 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
    IEC 61000-4-10 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-10: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY MAGNETIC FIELD IMMUNITY TEST
    IEC 60255-22-1:2007 Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests
    IEEE 62-1995 IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus - Part 1: Oil Filled Power Transformers, Regulators, and Reactors
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE C57.19.00 : 2004 GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS
    IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
    IEC 60255-22-5:2008 Measuring relays and protection equipment - Part 22-5: Electrical disturbance tests - Surge immunity test
    IEC 60076-4:1976 Power transformers - Part 4: Tappings and connections
    IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
    IEEE 315 : 1975 GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS)
    IEC 61000-4-9 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-9: TESTING AND MEASUREMENT TECHNIQUES - IMPULSE MAGNETIC FIELD IMMUNITY TEST
    IEEE C37.90.3-2001 IEEE Standard Electrostatic Discharge Tests for Protective Relays
    IEEE C57.104-2008 IEEE Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers
    IEEE C57.98-2011 IEEE Guide for Transformer Impulse Tests
    ANSI C84.1 : 2016 ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ)
    IEEE C2-2017 NATIONAL ELECTRICAL SAFETY CODE (NESC)(R)
    IEC 60255-22-6:2001 Electrical relays - Part 22-6: Electrical disturbance tests for measuring relays and protection equipment - Immunity to conducted disturbances induced by radio frequency fields
    IEC 60255-22-3:2007 Measuring relays and protection equipment - Part 22-3: Electrical disturbance tests - Radiated electromagnetic field immunity
    IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    IEEE C37.90.2:2004 WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS
    IEC 60255-5:2000 Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests
    IEEE C57.12.20-2011 REDLINE IEEE Standard for Overhead-Type Distribution Transformers 500 kVA and Smaller: High Voltage, 34 500 V and Below; Low Voltage, 7970/13 800Y V and Below
    IEEE C37.90.1-2012 IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus
    IEC 60255-22-2:2008 Measuring relays and protection equipment - Part 22-2: Electrical disturbance tests - Electrostatic discharge tests
    IEC 60255-21-1:1988 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section One: Vibration tests (sinusoidal)
    IEEE C57.12.31-2010 IEEE Standard for Pole-Mounted Equipment--Enclosure Integrity
    IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    IEEE C57.106-2006 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment
    IEC 60214-2:2004 Tap-changers - Part 2: Application guide
    IEC 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods
    IEC 60255-22-4:2008 Measuring relays and protection equipment - Part 22-4: Electrical disturbance tests - Electrical fast transient/burst immunity test
    IEEE C57.131-2012 IEEE Standard Requirements for Tap Changers
    IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective