• IEC 60079-13:2017

    Current The latest, up-to-date edition.

    Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French, English, Spanish, Castilian

    Published date:  22-05-2017

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements for all rooms
    5 Clean air supply
    6 Requirements for pressurized rooms
    7 Requirements for artificially ventilated rooms
    8 Marking
    9 Instructions
    Annex A (informative) - Maintenance
    Annex B (informative) - Guidelines when pressurization
            or artificial ventilation is not immediately restored
    Annex C (informative) - Examples of applications and
            associated guidelines
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC 60079-13:2017 gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment:
    – located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere without an internal source of gas/vapour release and protected by pressurization;
    – located in a Zone 2 explosive atmosphere with or without an internal source of gas/vapour release and protected by artificial ventilation;
    – located in a non-hazardous area, containing an internal source of gas/vapour release and protected by artificial ventilation;
    – located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere containing an internal source of gas/vapour release and protected by both pressurization and artificial ventilation.
    The term "room" used in this document includes single rooms, multiple rooms, a complete building or a room contained within a building. A room is intended to facilitate the entry of personnel and includes inlet and outlet ducts. An acoustic hood and other like enclosures designed to permit the entry of personnel can be considered as a room.
    This document also includes requirements related safety devices and controls necessary to ensure that artificial ventilation, purging and pressurization is established and maintained.
    A room assembled or constructed on site, can be either on land or off-shore. The room is primarily intended for installation by an end-user but could be constructed and assessed at a manufacturer’s facility, where the final construction such as ducting can be completed on site.
    This document does not specify the methods that may be required to ensure adequate air quality for personnel with regard to toxicity and temperature within the room. National or other regulations and requirements may exist to ensure the safety of personnel in this regard.
    This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision.
    This edition includes the following significant technical changes with respect to the previous edition:
    a) modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p";
    b) addition of types of protection "pb", "pc", and "vc" and removal of types of protection "px", "py", "pz" and "pv";
    c) definition of the differences between pressurization and artificial ventilation types of protection;
    d) removal of protection of rooms with an inert gas or a flammable gas from the scope of this document;
    e) addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines.

    General Product Information - (Show below) - (Hide below)

    Committee TC 31/SC 31J
    Development Note To be read in conjunction with IEC 60079-10-1 and IEC 60079-16. Stability Date: 2020. (05/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEC 60079-29-2 REDLINE : 2ED 2015 EXPLOSIVE ATMOSPHERES - PART 29-2: GAS DETECTORS - SELECTION, INSTALLATION, USE AND MAINTENANCE OF DETECTORS FOR FLAMMABLE GASES AND OXYGEN
    04/30117249 DC : DRAFT JUL 2004 IEC 60079-2 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 2: PRESSURIZED ENCLOSURES 'P'
    BS EN 61784-5-1:2013 Industrial communication networks. Profiles Installation of fieldbuses. Installation profiles for CPF 1
    17/30356593 DC : 0 BS EN ISO 15138 - PETROLEUM AND NATURAL GAS INDUSTRIES - OFFSHORE PRODUCTION INSTALLATIONS - HEATING, VENTILATION AND AIR-CONDITIONING
    18/30369304 DC : DRAFT APR 2018 BS EN 1473 - INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
    I.S. EN 61779-1:2003 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    NFPA 496 : 2017 PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT
    DIN EN 1473:2016-10 Installation and equipment for liquefied natural gas - Design of onshore installations
    EN 50381 : 2004 COR 2005 TRANSPORTABLE VENTILATED ROOMS WITH OR WITHOUT AN INTERNAL SOURCE OF RELEASE
    I.S. EN 60079-2:2014 EXPLOSIVE ATMOSPHERES - PART 2: EQUIPMENT PROTECTION BY PRESSURIZED ENCLOSURE 'P'
    BS EN 60079-29-2:2015 Explosive atmospheres Gas detectors. Selection, installation, use and maintenance of detectors for flammable gases and oxygen
    CSA PLUS 2203 : 2001 HAZARDOUS LOCATIONS - GUIDE FOR THE DESIGN, TESTING, CONSTRUCTION, AND INSTALLATION OF EQUIPMENT IN EXPLOSIVE ATMOSPHERES
    BS EN 50381:2004 Transportable ventilated rooms with or without an internal source of release
    I.S. EN 61784-5-1:2013 INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-1: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 1
    ISA 12.13.01 : 2003 PERFORMANCE REQUIREMENTS FOR COMBUSTIBLE GAS DETECTORS
    C22.1-15 PACKAGE Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference
    IEC TR 61831:2011 On-line analyser systems - Guide to design and installation
    BS EN 1473:2016 Installation and equipment for liquefied natural gas. Design of onshore installations
    IEC 61779-1:1998 Electrical apparatus for the detection and measurement of flammable gases - Part 1: General requirements and test methods
    DIN EN 1473:1997-11 INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
    Z462-18 Workplace electrical safety
    I.S. EN 1473:2016 INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
    C22.1HB-18 Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I
    EN 60079-14:2014/AC:2016 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016)
    DIN EN 61779-1 : 2001 AMD 11 2004 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    PREN 1473 : DRAFT 2018 INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
    BS IEC 61832:1999 Analyser systems. Guide to technical enquiry and bid evaluation
    PD IEC/TS 60079-40:2015 Explosive atmospheres Requirements for process sealing between flammable process fluids and electrical systems
    EN 1473:2016 Installation and equipment for liquefied natural gas - Design of onshore installations
    05/30128234 DC : DRAFT FEB 2005 EN 1473 - INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
    04/30112677 DC : 0 IEC 61779-1 ED.2 - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    14/30310243 DC : 0 BS EN 60079-40 - EXPLOSIVE ATMOSPHERES - REQUIREMENTS FOR PROCESS SEALING BETWEEN FLAMMABLE OR COMBUSTIBLE PROCESS FLUIDS AND ELECTRICAL SYSTEMS
    SAE J 2578 : 2014 RECOMMENDED PRACTICE FOR GENERAL FUEL CELL VEHICLE SAFETY
    IEC 61779-6:1999 Electrical apparatus for the detection and measurement of flammable gases - Part 6: Guide for the selection, installation, use and maintenance of apparatus for the detection and measurement of flammable gases
    I.S. EN 60079-29-2:2015 EXPLOSIVE ATMOSPHERES - PART 29-2: GAS DETECTORS - SELECTION, INSTALLATION, USE AND MAINTENANCE OF DETECTORS FOR FLAMMABLE GASES AND OXYGEN
    CEI EN 50381 : 2006 TRANSPORTABLE VENTILATED ROOMS WITH OR WITHOUT AN INTERNAL SOURCE OF RELEASE
    EEMUA 186 : 2016 A PRACTITIONER'S HANDBOOK FOR POTENTIALLY EXPLOSIVE ATMOSPHERES
    UNE-EN 60079-14:2016 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
    BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
    EEMUA 138 : 2010 DESIGN AND INSTALLATION OF ON-LINE ANALYSER SYSTEMS
    CSA CE CODE SAFETY PACKAGE : 2012 CE CODE SAFETY PACKAGE
    13/30271477 DC : 0 BS EN 61285 ED 3.0 - INDUSTRIAL-PROCESS CONTROL - SAFETY OF ANALYSER HOUSES
    C22.10-10 Québec Construction Code, Chapter V - Electricity Canadian Electrical Code, Part I (Twenty-first Edition) with Québec Amendments
    CSA E60079.2 : 2002 : R2011 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL APPARATUS - TYPE OF PROTECTION "p"
    BS EN 60079-2:2014 Explosive atmospheres Equipment protection by pressurized enclosure \'p\'
    CSA E60079.2:2002 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ELECTRICAL APPARATUS - TYPE OF PROTECTION "p"
    CSA C22.2 No. 60079-2 : 2016 EXPLOSIVE ATMOSPHERES - PART 2: EQUIPMENT PROTECTION BY PRESSURIZED ENCLOSURE 'P'
    API 505 : 1997 RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS I, ZONE 0, ZONE 1, AND ZONE 2
    IEC 60079-0:2017 Explosive atmospheres - Part 0: Equipment - General requirements
    CEI EN 60079-29-2 : 2016 EXPLOSIVE ATMOSPHERES - PART 29-2: GAS DETECTORS - SELECTION, INSTALLATION, USE AND MAINTENANCE OF DETECTORS FOR FLAMMABLE GASES AND OXYGEN
    I.S. EN 50381:2004 TRANSPORTABLE VENTILATED ROOMS WITH OR WITHOUT AN INTERNAL SOURCE OF RELEASE
    IEC TS 60079-40:2015 Explosive atmospheres - Part 40: Requirements for process sealing between flammable process fluids and electrical systems
    IEC 61892-7:2014 Mobile and fixed offshore units - Electrical installations - Part 7: Hazardous areas
    IEC 60079-0:2017 RLV Explosive atmospheres - Part 0: Equipment - General requirements
    05/30138005 DC : DRAFT AUG 2005 IEC 60079-14 ED 4 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES)
    12/30276304 DC : 0 BS EN 61892-7 ED 3.0 - MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 7: HAZARDOUS AREAS
    IEC 60079-29-2:2015 RLV Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
    IEC 61784-5-1:2013 Industrial communication networks - Profiles - Part 5-1: Installation of fieldbuses - Installation profiles for CPF 1
    UNE-EN 60079-2:2015 Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"
    PD IEC/TR 61831:2011 On-line analyser systems. Guide to design and installation
    BS IEC 61831:1999 On-line analyser systems. Guide to design and installation
    IEC 60309-3:1994 Plugs, socket-outlets and couplers for industrial purposes - Part 3: Particular requirements for plugs, socket-outlets, connectors and appliance inlets for use in explosive gas atmospheres
    I.S. EN 60079-14:2014 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
    14/30297213 DC : 0 BS EN 1473 - INSTALLATION AND EQUIPMENT FOR LIQUEFIED NATURAL GAS - DESIGN OF ONSHORE INSTALLATIONS
    BS EN 61779-1:2000 Electrical apparatus for the detection and measurement of flammable gases General requirements and test methods
    CEI EN 61784-5-1 : 2014 INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 5-1: INSTALLATION OF FIELDBUSES - INSTALLATION PROFILES FOR CPF 1
    ISO 15138:2007 Petroleum and natural gas industries Offshore production installations Heating, ventilation and air-conditioning
    UNE-EN 60079-29-2:2016 Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
    IEC 60079-0 REDLINE : 7.0 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
    C22.1-18 Canadian Electrical Code, Part I (24th Edition), Safety Standard for Electrical Installations
    12/30269297 DC : 0 BS EN 60079-14/ED 5 - EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION
    BS IEC 61892-7:2014 Mobile and fixed offshore units. Electrical installations Hazardous areas
    EN 60079-2:2014/AC:2015 EXPLOSIVE ATMOSPHERES - PART 2: EQUIPMENT PROTECTION BY PRESSURIZED ENCLOSURE 'P' (IEC 60079-2:2014)
    EN 61779-1 : 2000 AMD 11 2004 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    EN 61784-5-1:2013 Industrial communication networks - Profiles - Part 5-1: Installation of fieldbuses - Installation profiles for CPF 1
    EN 60079-29-2:2015 Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
    IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
    IEC 60079-10-1:2015 Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
    IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
    IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
    IEC 61285:2015 Industrial-process control - Safety of analyser houses
    IEC TR 61831:2011 On-line analyser systems - Guide to design and installation
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective