• IEC 60364-7-715:2011

    Current The latest, up-to-date edition.

    Low-voltage electrical installations - Part 7-715: Requirements for special installations or locations - Extra-low-voltage lighting installations

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French, Spanish, Castilian

    Published date:  14-12-2011

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    715 Extra-low-voltage lighting installations
    715.1 Scope
    715.2 Normative references
    715.4 Protection for safety
    715.41 Protection against electric shock
    715.414 Protective measure: extra-low-voltage provided
                by SELV and PELV
    715.42 Protection against thermal effects
    715.422.3 Locations with risks of fire due to the nature
                of processed or stored materials
    715.422.106 Fire risk of transformers/convertors
    715.422.107 Fire risk due to short-circuit
    715.43 Protection against overcurrent
    715.430.104 Protection against overcurrent in ELV lighting
                installations
    715.5 Selection and erection of electrical equipment
    715.52 Wiring systems
    715.521 Types of wiring system
    715.521.106 Bare conductors
    715.521.107 Suspended systems
    715.523 Current-carrying capacities
    715.524 Cross-sectional areas of conductors
    715.525 Voltage drop in consumers' installations
    715.53 Isolation, switching and control
    715.530.3 General and common requirements
    715.536 Isolation and switching
    Annex A (informative) - List of notes concerning certain
            countries
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC 60364-5-55:2011 The particular requirements apply to extra-low-voltage lighting installations supplied from sources with a maximum rated voltage of 50 V a.c. or 120 V d.c. For the definition of an extra-low voltage lighting system reference should be made to IEC 60598-2-23. This second edition cancels and replaces the first edition, published in 1999, and constitutes a technical revision. The major technical changes with respect to the previous edition are:
    - the clause numbering is aligned with the present structure of IEC 60364;
    - references to LED modules and their particular installation requirements have been introduced;
    - and requirements for cross-sectional area of conductors are modified.

    General Product Information - (Show below) - (Hide below)

    Committee TC 64
    Development Note Stability Date: 2021. (10/2012)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    EN 62838:2016/AC:2017-11 LEDSI LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATIONS
    HD 60364-5-52:2011/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
    I.S. EN 62838:2016 LEDSI LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATIONS
    IEC 61991:2000 Railway applications - Rolling stock - Protective provisions against electrical hazards
    IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
    I.S. HD 60364-5-52:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
    13/30281739 DC : 0 BS EN 62838 - SELF-BALLASTED LED-LAMPS FOR GENERAL LIGHTING SERVICES WITH SUPPLY VOLTAGES NOT EXCEEDING 50 V A.C. R.M.S. OR 120 V RIPPLE FREE D.C. - SAFETY SPECIFICATION
    S.R. HD 60364-5-52:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
    BS EN 62838:2016 LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. Safety specifications
    BS EN 50491-3:2009 General requirements for home and building electronic systems (HBES) and building automation and control systems (BACS) Electrical safety requirements
    UNE-EN 62838:2016 LEDsi lamps for general lighting services with supply voltages not exceeding 50 v a.c. r.m.s. or 120 v ripple free D.C. - Safety specifications
    UNE-EN 50491-3:2010 General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 3: Electrical safety requirements
    I.S. EN 50491-3:2009 GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 3: ELECTRICAL SAFETY REQUIREMENTS
    EN 50491-3:2009 General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 3: Electrical safety requirements
    UNE-HD 60364-5-52:2014 Low-voltage electrical installations -- Part 5-52: Selection and erection of electrical equipment - Wiring systems

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60364-4-43:2008 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
    IEC 60598-2-23:1996+AMD1:2000 CSV Luminaires - Part 2-23: Particular requirements - Extra low voltage lighting systems for filament lamps
    IEC 61347-2-13:2014+AMD1:2016 CSV Lamp controlgear - Part 2-13: Particular requirements for d.c. ora.c. supplied electronic controlgear for LED modules
    IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
    IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control
    IEC 60570:2003+AMD1:2017 CSV Electrical supply track systems for luminaires
    IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
    IEC 60364-1:2005 Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions
    IEC 60998-2-2:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units
    IEC 61347-2-2:2011 Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps
    IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment
    AS/NZS 62838:2020 LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. - Safety specifications (IEC 62838:2015 (ED.1.0)/COR1:2017, MOD)
    IEC 60364-4-42:2010+AMD1:2014 CSV Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects
    IEC 60998-2-1:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units
    IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective