• IEC 60660:1999

    Current The latest, up-to-date edition.

    Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 000 V up to but not including 300 kV

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French, Spanish, Castilian

    Published date:  29-10-1999

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 General
          1.1 Scope and Object
          1.2 Normative References
          1.3 Definitions
          1.4 Values which characterise a post insulator of
                 organic material
          1.5 Documentation
          1.6 Normal Service Conditions
    2 General Requirements for Tests
          2.1 Classification of Tests
          2.2 Quality Assurance
          2.3 General Requirements for Electrical Tests
          2.4 Lightning Impulse Voltage Tests
          2.5 Power-Frequency Voltage Tests
          2.6 Standard Reference Atmospheric Conditions for
                 Tests
          2.7 Correction Factors for Atmospheric Conditions
    3 Type Tests
          3.1 General
          3.2 General Requirements for Electrical Type Tests
          3.3 Dry Lightning Impulse Withstand Voltage Test
          3.4 Dry Power-Frequency Withstand Voltage Test
          3.5 Partial Discharge Extinction Voltage Test
          3.6 Lightning Impulse Puncture Test
          3.7 Mechanical Failing Load Test
          3.8 Test for Deflection Under Load at Normal Ambient
                 Temperature Conditions
          3.9 Test for Mechanical bending strength as a
                 function of temperature
          3.10 Water Absorption Test
          3.11 Ageing and Humidity Test
          3.12 Flammability Test
          3.13 Temperature Cycle Test
    4 Sample Tests
          4.1 General
          4.2 Verification of Dimensions
          4.3 Re-Test Procedure
    5 Routine Tests
          5.1 General
          5.2 Visual Examination
          5.3 Mechanical Routine Test
          5.4 Electrical Routine Test and Partial Discharge
                 Measurement
    Annex A (informative) Tolerances of Form and Position

    Abstract - (Show below) - (Hide below)

    Applicable to post insulators of organic material for indoor service in electrical installations or equipment operating in air at atmospheric pressure on alternating current with a nominal voltage greater than 1 000 V up, but not including, 300 kV, as defined by range I of IEC 60071-1, and a frequency not greater than 100 Hz. Composite insulators are not covered by this standard.

    General Product Information - (Show below) - (Hide below)

    Committee TC 36
    Development Note Also numbered as BS EN 60660. (10/2005) Stability Date: 2019. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNE-EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
    BS EN 50119 : 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    BS EN 61869-1:2009 Instrument transformers General requirements
    13/30281408 DC : 0 BS EN 61869-10 - INSTRUMENT TRANSFORMERS - PART 10: ADDITIONAL REQUIREMENTS FOR LOW-POWER, STAND-ALONE CURRENT SENSORS
    15/30298489 DC : 0 BS EN 50124-1 - RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
    PREN 50119 : DRAFT 2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    IEC TS 61462:1998 Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations
    IEC 62497-1:2010+AMD1:2013 CSV Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment
    07/30167174 DC : 0 BS EN 61869-2 - INSTRUMENT TRANSFORMERS - PART 2: SPECIFIC REQUIREMENT FOR CURRENT TRANSFORMERS
    11/30215604 DC : 0 BS IEC 60913 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    07/30167396 DC : 0 BS EN 61869-4 - INSTRUMENT TRANSFORMERS - PART 4 - SPECIFIC REQUIREMENT FOR COMBINED TRANSFORMERS
    PREN 50124-1 : DRAFT 2015 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
    EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
    I.S. EN 50124-1:2017 RAILWAY APPLICATIONS - INSULATION COORDINATION - PART 1: BASIC REQUIREMENTS - CLEARANCES AND CREEPAGE DISTANCES FOR ALL ELECTRICAL AND ELECTRONIC EQUIPMENT
    I.S. EN 50119:2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    IEC 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements
    VDE 0674-1 : 2001-12 TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV
    DIN EN 60168 : 2001-12 TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV
    BS 3297-2:1993 Characteristics of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V
    14/30284930 DC : 0 BS EN 62689-2 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: GENERAL PRINCIPLES AND REQUIREMENTS
    I.S. EN 61869-1:2009 INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    CSA C61869-1 : 2014 INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    UNE-EN 61869-1:2010 Instrument transformers -- Part 1: General requirements
    EN 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements
    17/30341013 DC : DRAFT AUG 2017 BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    BS EN 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements
    I.S. EN 62689-1:2016 CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS
    IEC 60913:2013 Railway applications - Fixed installations - Electric traction overhead contact lines
    I.S. EN 50119:2020 Railway applications - Fixed installations - Electric traction overhead contact lines
    EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    12/30268049 DC : 0 BS EN 62689-1 - CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS
    BS EN 50124-1:2017 Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment
    CEI EN 61869-1 : 2010 INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    IEC 61869-1:2007 Instrument transformers - Part 1: General requirements
    EN 61869-1:2009 Instrument transformers - Part 1: General requirements

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
    IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
    ISO 9002:1994 Quality systems — Model for quality assurance in production, installation and servicing
    IEC 60273:1990 Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V
    IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
    IEC 60587:2007 Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    ISO 9000-1:1994 Quality management and quality assurance standards — Part 1: Guidelines for selection and use
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective