• IEC 61196-3:1998

    Current The latest, up-to-date edition.

    Radio frequency cables - Part 3: Sectional specification for coaxial cables for use in local area networks

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French, Spanish, Castilian

    Published date:  30-07-1998

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Contents
    Foreword
    Clause
    1. General
        1.1 Scope and object
        1.2 Normative references
        1.3 Definitions
        1.4 Installation considerations
             1.4.1 Pulling strength
             1.4.2 Temperature rating
             1.4.3 Bending radius
    2. Materials and cable construction
        2.1 General
        2.2 Cable construction
        2.3 Inner conductor
             2.3.1 Conductor material
             2.3.2 Conductor construction
        2.4 Dielectric
        2.5 Outer conductor or screen
        2.6 Sheath
        2.7 Colour of the sheath
        2.8 Identification
             2.8.1 Cable identification
             2.8.2 Sheath marking
        2.9 Delivery and storage
    3. Characteristics and requirements
        3.1 General
        3.2 Engineering information
             3.2.1 Connector
             3.2.2 Mass
             3.2.3 Bending radius
             3.2.4 Capacitance
             3.2.5 Voltage rating
        3.3 Electrical integrity
             3.3.1 Sheath spark test
             3.3.2 Dielectric withstand voltage
             3.3.3 Insulation resistance
        3.4 Transmission characteristics
             3.4.1 Characteristic impedance
             3.4.2 Loop DCR
             3.4.3 Outer conductor DCR
             3.4.4 Attenuation
             3.4.5 Attenuation after ageing
             3.4.6 Velocity ratio
             3.4.7 Surface transfer impedance
             3.4.8 Screening attenuation
             3.4.9 Return loss
        3.5 Mechanical characteristics
             3.5.1 Elongation after break of the inner conductor
             3.5.2 Elongation after break of the insulation
             3.5.3 Tensile strength and elongation after break
                    of the sheath
             3.5.4 Tensile strength and elongation after break of
                    the sheath after ageing
             3.5.5 Bending at low temperature of the cable
             3.5.6 Bending radius at room temperature
             3.5.7 Dielectric adhesion
        3.6 Environmental characteristics
             3.6.1 Cable test under fire conditions
             3.6.2 Smoke opacity, toxicity, halogen gas emission
    4. Quality assurance
    5. Blank detail specification
        5.1 Field of application
        5.2 Identification of the detail specification
        5.3 Pro forma blank detail specification
    Figure 1 - Maximum transfer frequency

    Abstract - (Show below) - (Hide below)

    Prescribes recommended ratings and characteristics and selects from the generic specification the appropriate quality assessment procedures, test and measuring methods, and gives general performance requirements for coaxial cables for local area networks plus complementary test methods. Test severities and requirements prescribed in detail specifications referring to this sectional specification should be of equal or higher performance levels. When the requirements of IEC 61196-1 and of this sectional specification conflict with each other, this sectional specification shall prevail.

    General Product Information - (Show below) - (Hide below)

    Committee TC 46/SC 46A
    Development Note Also numbered as BS EN 61196-3 (11/2005) Stability Date: 2020. (11/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 45510-2-9:2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
    EN 45510-2-9:2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
    EN 45510-2-9 : 2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
    BS EN 45510-2-9:2008 Guide for procurement of power station equipment Electrical equipment. Cabling systems

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60028:1925 International standard of resistance for copper
    IEC 60304:1982 Standard colours for insulation for low-frequency cables and wires
    IEC 60332-1:1993 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
    IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
    IEC 61196-1:2005 Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective