• IEC TR 61200-704:1996

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Electrical installation guide - Part 704: Construction and demolition site installations

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Withdrawn date:  12-09-2022

    Language(s):  English - French

    Published date:  28-03-1996

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    Clause
    704.1 Scope
    704.2 Normative references and definitions
    704.3 Assessment of general characteristics
           704.312 Types of distribution systems
           704.32 Conditions of external influences
           704.36 Safety circuits
    704.4 Protection for safety
           704.41 Protection against electric shock
           704.43 Protection against overcurrent
    704.5 Selection and erection of equipment
           704.51 Common rules
           704.52 Wiring systems
           704.53 Switchgear and controlgear
           704.54 Earthing arrangements and protective
                   conductors
    704.6 Verification
           704.61 Initial verification
           704.62 Periodic verification
           704.63 Supervision
           704.64 Maintenance

    Abstract - (Show below) - (Hide below)

    This report gives more detailed guidance on the application of the requirements of IEC 60364 to these particular types of installation. To make it easier for users, definitions are repeated, and several examples of important items are listed. It is for use as a guide for temporary installations provided only for the period of construction, during which they may be frequently modified and relocated.

    General Product Information - (Show below) - (Hide below)

    Development Note Stability Date: 2018. (10/2012)
    Document Type Technical Report
    Publisher International Electrotechnical Committee
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    ISO/IEC 18010:2002 Information technology Pathways and spaces for customer premises cabling
    10/30218813 DC : 0 BS EN 61439-4 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: ASSEMBLIES FOR CONSTRUCTION SITES (ACS)
    UNE-EN 61439-4:2013 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
    CSA ISO/IEC 18010 :2004 INFORMATION TECHNOLOGY - PATHWAYS AND SPACES FOR CUSTOMER PREMISES CABLING
    IEC 61439-4:2012 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
    I.S. EN 61439-4:2013 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR CONSTRUCTION SITES (ACS) (IEC 61439-4:2012 (EQV))
    BS EN 61439-4:2013 Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS)
    CSA ISO/IEC 18010 : 2004 : INC : AMD 1 : 2006 : R2012 INFORMATION TECHNOLOGY - PATHWAYS AND SPACES FOR CUSTOMER PREMISES CABLING
    EN 61439-4:2013 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60364-5-54:2011 Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors
    IEC 60364-4-43:2008 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
    IEC 61024-1:1990 Protection of structures against lightning - Part 1: General principles
    IEC 60364-4-473:1977+AMD1:1998 CSV Electrical installations of buildings - Part 4: Protection for safety - Chapter 47: Application of protective measures for safety - Section 473: Measures of protection against overcurrent
    IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
    IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
    IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control
    IEC 60364-7-704:2017 Low-voltage electrical installations - Part 7-704: Requirements for special installations or locations - Construction and demolition site installations
    IEC 60245-4:2011 Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables
    IEC 60364-3:1993 Electrical installations of buildings - Part 3: Assessment of general characteristics
    IEC 60364-6-61:2001 Electrical installations of buildings - Part 6-61: Verification - Initial verification
    IEC 60364-7-706:2005 Low-voltage electrical installations - Part 7-706: Requirements for special installations or locations - Conducting locations with restricted movement
    IEC 60598-2-22:2014+AMD1:2017 CSV Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting
    IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
    IEC 60439-4:2004 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
    IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective