• IEC 61241-10:2004

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electrical apparatus for use in the presence of combustible dust - Part 10: Classification of areas where combustible dusts are or may be present

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  20-04-2009

    Language(s):  English - French, Spanish, Castilian

    Published date:  07-06-2004

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Area classification for combustible dusts
      4.1 General
      4.2 Area classification objectives for explosive dust
          atmospheres
      4.3 Area classification procedure for explosive dust
          atmospheres
    5 Sources of release for explosive dust atmospheres
      5.1 General
      5.2 Identification of sources of release
    6 Zones for explosive dust atmospheres
      6.1 General
      6.2 Zones for dusts
      6.3 Examples of zones for explosive dust atmospheres
      6.4 Extent of zones for explosive dust atmospheres
    7 Dust layer hazard
    8 Documentation
      8.1 General
      8.2 Drawings, data sheets and tables
    Annex A (informative) Area classification application
    Annex B (informative) Risk of fire from hot surface ignition of
                          dust layer
    Annex C (informative) Housekeeping
    Bibliography

    Abstract - (Show below) - (Hide below)

    Deals with the classification of areas where explosive dust/air mixtures and combustible dust layers are present, in order to permit the proper selection of equipment for use in such areas.The principles of the standard can also be followed when combustible fibres or flyings may cause a hazard.To be applied where there can be a risk due to the presence of explosive dust/air mixtures or combustible dust layers under normal atmospheric conditions.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes IEC 61241-3. (06/2004)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 61241-17:2005 Electrical apparatus for use in the presence of combustible dust Inspection and maintenance of electrical installations in hazardous areas (other than mines)
    BS EN 14677:2008 Safety of machinery. Secondary steelmaking. Machinery and equipment for treatment of liquid steel
    I.S. EN 61241-1:2004 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1: PROTECTION BY ENCLOSURES "TD"
    BS EN 61241-14:2004 Electrical apparatus for use in the presence of combustible dust Selection and installation
    EN 61241-14:2004 Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation
    EN 61241-1:2004/corrigendum Dec. 2006 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1: PROTECTION BY ENCLOSURES "TD"
    EN 61241-17:2005 Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
    NF EN 14677 : 2008 SAFETY OF MACHINERY - SECONDARY STEELMAKING - MACHINERY AND EQUIPMENT FOR TREATMENT OF LIQUID STEEL
    BS EN 61241-1:2004 Electrical apparatus for use in the presence of combustible dust Protection by enclosures \'tD\'
    08/30180312 DC : DRAFT MAR 2008 BS EN 50223 - STATIONARY ELECTROSTATIC APPLICATION EQUIPMENT FOR IGNITABLE FLOCK MATERIAL - SAFETY REQUIREMENTS
    I.S. EN 61241-14:2004 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 14: SELECTION AND INSTALLATION
    02/204778 DC : DRAFT JULY 2002 IEC 61241-0 ED.1 - ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 0: GENERAL REQUIREMENTS
    DIN EN 12981:2010-06 COATING PLANTS - SPRAY BOOTHS FOR APPLICATION OF ORGANIC POWDER COATING MATERIAL - SAFETY REQUIREMENTS
    BS EN 12981 : 2005 COATING PLANTS - SPRAY BOOTHS FOR APPLICATION OF ORGANIC POWDER COATING MATERIAL - SAFETY REQUIREMENTS
    I.S. EN 12981:2005 COATING PLANTS - SPRAY BOOTHS FOR APPLICATION OF ORGANIC POWDER COATING MATERIAL - SAFETY REQUIREMENTS
    BIS IS/IEC 60079-18 : 2009 EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION 'M'
    VDI 2263 Blatt 7:2010-07 Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in spraying and drying integrated equipment
    07/30174641 DC : DRAFT DEC 2007 BS EN 62305-3 - PROTECTION AGAINST LIGHTNING - PART 3: PHYSICAL DAMAGE TO STRUCTURES AND LIFE HAZARD
    DIN EN 14677:2008-11 SAFETY OF MACHINERY - SECONDARY STEEL MAKING - MACHINERY AND EQUIPMENT FOR TREATMENT OF LIQUID STEEL
    02/204779 DC : DRAFT JULY 2002 IEC 61241-17 ED.1 - ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES)
    I.S. EN 61241-17:2005 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 17: INSPECTION AND MAINTENANCE OF ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES)
    EEMUA 186 : 2016 A PRACTITIONER'S HANDBOOK FOR POTENTIALLY EXPLOSIVE ATMOSPHERES
    IEC 61241-14:2004 Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation
    IEC 61241-17:2005 Electrical apparatus for use in the presence of combustible dust - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
    UNI EN 14677 : 2008 SAFETY OF MACHINERY - SECONDARY STEELMAKING - MACHINERY AND EQUIPMENT FOR TREATMENT OF LIQUID STEEL
    UNI EN 12981 : 2009 COATING PLANTS - SPRAY BOOTHS FOR APPLICATION OF ORGANIC POWDER COATING MATERIAL - SAFETY REQUIREMENTS
    08/30191891 DC : DRAFT OCT 2008 BS EN 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
    10/30216256 DC : 0 BS EN 60335-2-69 - HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-69: PARTICULAR REQUIREMENTS FOR WET AND DRY VACUUM CLEANERS, INCLUDING POWER BRUSH, FOR COMMERCIAL USE
    08/30195352 DC : 0 BS EN 60335-2-69 FPRAC - HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-69: PARTICULAR REQUIREMENTS FOR WET AND DRY VACUUM CLEANERS, INCLUDING POWERBRUSH, FOR INDUSTRIAL AND COMMERCIAL USE
    07/30174633 DC : DRAFT DEC 2007 BS EN 62305-2 - PROTECTION AGAINST LIGHTNING - PART 2: RISK MANAGEMENT
    ISA 61241-1 : 2006 ELECTRICAL APPARATUS FOR USE IN ZONE 20, ZONE 21 AND ZONE 22 HAZARDOUS (CLASSIFIED) LOCATIONS - PROTECTION BY ENCLOSURES "TD"
    IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
    07/30169755 DC : 0 BS EN 60364-5-53 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING
    IEC 61241-1:2004 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
    EN 14677:2008 Safety of machinery - Secondary steelmaking - Machinery and equipment for treatment of liquid steel
    02/205211 DC : DRAFT JULY 2002 IEC 61241-14 ED.1 - ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 14: SELECTION AND INSTALLATION
    02/205209 DC : DRAFT JULY 2002 IEC 61241-1 ED.1 - ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1: PROTECTION BY ENCLOSURES 'TD'
    07/30169774 DC : 0 BS EN 60364-5-53 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING
    11/30247086 DC : 0 BS EN 60079-1 ED. 7.0 - EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D"
    BIS IS/IEC 60079-1 : 2007 EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D'
    DIN EN 14677 E : 2008 SAFETY OF MACHINERY - SECONDARY STEELMAKING - MACHINERY AND EQUIPMENT FOR TREATMENT OF LIQUID STEEL
    I.S. EN 14677:2008 SAFETY OF MACHINERY - SECONDARY STEELMAKING - MACHINERY AND EQUIPMENT FOR TREATMENT OF LIQUID STEEL
    API 14FZ : 2013 RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS
    EN 12981:2005+A1:2009 Coating plants - Spray booths for application of organic powder coating material - Safety requirements

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 4225:1994 Air quality General aspects Vocabulary
    IEC 61241-0:2004 Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
    IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
    IEC 61241-14:2004 Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective