• IEC 61243-5:1997

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Live working - Voltage detectors - Part 5: Voltage detecting systems (VDS)

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  31-12-2021

    Language(s):  English - French, Spanish, Castilian

    Published date:  05-06-1997

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Definitions
    4 Requirements
        4.1 General
        4.2 Threshold values for indication
        4.3 Indication and perceptibility
        4.4 Climatic requirements
        4.5 Coupling dielectric
        4.6 Measuring circuit components
        4.7 Connecting lead
        4.8 Interface and test point
        4.9 Indicator
        4.10 Terminal leads of separable indicators
        4.11 Markings
        4.12 Instructions for use
    5 Tests
        5.1 General
        5.2 Arrangement, assembly, markings and instructions
              for use
        5.3 Dielectric strength of the coupling system or
              integrated VDS
        5.4 Maximum current from the coupling electrode
        5.5 Interface conditions for separable VDS
        5.6 Voltage limiting device
        5.7 Temperature dependence of coupling systems of
              separable VDS and of integrated VDS
        5.8 Phase rotation of the coupling system
        5.9 Insulation resistance of the coupling system
              under pollution
        5.10 Connecting leads
        5.11 Clear indication in integrated VDS
        5.12 Vibration resistance of the indicator for
              separable and integrated VDS
        5.13 Drop and impact resistance
        5.14 Dielectric strength of separable indicators
        5.15 Threshold voltage and input impedance of indicators
        5.16 Climatic dependence of threshold voltage
        5.17 Response time of indicator
        5.18 Non-response to d.c. voltage
        5.19 Efficiency of testing element
        5.20 Indication until power source is exhausted
        5.21 Temperature dependence of the separable
              indicator
        5.22 Clear perceptibility of visual indication
        5.23 Clear perceptibility of audible indication
        5.24 Clear indication of phase comparators
        5.25 Phase rotation of universal phase comparator
        5.26 Maintenance test of the coupling system of
              separable VDS
        5.27 Maintenance test of voltage indicators of
              separable VDS
        5.28 Maintenance test of integrated VDS
    Tables
    1 Characteristics of separable voltage detecting
        systems (VDS)
    2 Dimensional characteristics of interface and test point
    Figures
    1 Voltage detecting system with portable indicator
        (separable VDS)
    2 Voltage detecting system with integrated indicator
        (integrated VDS)
    3 Voltage detecting system with portable indicator
        and adaptor Example for HR-LR
    4 Symbol for capacitive interface
    5 Example for markings of an interface in the HR-system
    6 Examples for measuring the response time
    7 Test set-up for perceptibility of visual indication
    8 Test set-up for perceptibility of audible indication
    9 Test set-up for clear indication and phase rotation
        of phase comparators
    Annexes
    A Sequence of tests
    B Instructions for use of the VDS
    C Dimensional characteristics of plug arrangements
    D Sampling test
    E Tightness test for separable connectors containing
        LRP coupling systems
    F Voltage indicating systems

    Abstract - (Show below) - (Hide below)

    Is applicable to voltage detecting systems that are single-pole and are capacitively-coupled to live parts. They are used to detect the presence or absence of operating voltage on a.c. electrical systems for voltages from 1 kV to 52 kV, and for frequencies from 16 2/3 Hz to 60 Hz. This standard is also applicable to phase comparators designed for voltage detecting systems.

    General Product Information - (Show below) - (Hide below)

    Committee TC 78
    Development Note Stability Date: 2017. (10/2012)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded

    Standards Referenced By This Book - (Show below) - (Hide below)

    15/30314789 DC : 0 BS EN 50152-3-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-1: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - DEVICES
    PREN 50152-3-1 : DRAFT 2015 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-1: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - DEVICES
    NF EN 62271-206 : 2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 206: VOLTAGE PRESENCE INDICATING SYSTEMS FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
    BS EN 61958:2001 High-voltage prefabricated switchgear and controlgear assemblies. Voltage presence indicating systems
    HD 637 S1:1999/corrigendum:2005 POWER INSTALLATIONS EXCEEDING 1 KV A.C.
    EN 50152-3-1:2017 Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-1: Measurement, control and protection devices for specific use in a.c. traction systems - Devices
    MIL-DTL-32483 Base Document:2013 Switchgear, Power, Hard-Mounted, Medium Voltage, Naval Shipboard
    MIL-DTL-917 Revision F:2014 ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR
    BS EN 62271-206:2011 High-voltage switchgear and controlgear Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kVkV and up to and including 52 kV
    IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
    IEC 61958:2000 High-voltage prefabricated switchgear and controlgear assemblies - Voltage presence indicating systems
    09/30205947 DC : 0 BS EN 62271-206 ED1 - HIGH-VOLTAGE PREFABRICATED SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 206: VOLTAGE PRESENCE INDICATING SYSTEMS
    I.S. EN 62271-206:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 206: VOLTAGE PRESENCE INDICATING SYSTEMS FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
    08/30191891 DC : DRAFT OCT 2008 BS EN 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
    I.S. EN 50152-3-1:2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-1: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - DEVICES
    CEI EN 62271-206 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 206: VOLTAGE PRESENCE INDICATING SYSTEMS FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
    BS EN 50152-3-1:2017 Railway applications. Fixed installations. Particular requirements for a.c. switchgear Measurement, control and protection devices for specific use in a.c. traction systems. Devices
    I.S. HD 637:1999 POWER INSTALLATIONS EXCEEDING 1 KV A.C.
    I.S. EN 61958:2001 HIGH-VOLTAGE PREFABRICATED SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - VOLTAGE PRESENCE INDICATING SYSTEMS
    IEC 62271-206:2011 High-voltage switchgear and controlgear - Part 206: Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kV
    EN 61958:2001 High-voltage prefabricated switchgear and controlgear assemblies - Voltage presence indicating systems
    EN 62271-206:2011 High-voltage switchgear and controlgear - Part 206: Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kV

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60356:1971 Dimensions for commutators and slip-rings
    ISO 3744:2010 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane
    IEC 60068-2-63:1991 Environmental testing - Part 2: Test methods - Test Eg: Impact, spring hammer.
    IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
    IEC 60227-3:1993+AMD1:1997 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring
    IEC 60068-2-11:1981 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
    ISO 3740:2000 Acoustics Determination of sound power levels of noise sources Guidelines for the use of basic standards
    IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
    IEC 60352-1:1997 Solderless connections - Part 1: Wrapped connections - General requirements, test methods and practical guidance
    ISO 3746:2010 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Survey method using an enveloping measurement surface over a reflecting plane
    IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
    IEC 60225:1966 Octave, half-octave and third-octave band filters intended for the analysis of sounds and vibrations
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60352-2:2006+AMD1:2013 CSV Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    ISO 3745:2012 Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for anechoic rooms and hemi-anechoic rooms
    IEC 61010-2-031:1993 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-031: Particular requirements for hand-held probe assemblies for electrical measurement and test
    IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
    IEC 60651:1979+AMD1:1993+AMD2:2000 CSV Sound level meters
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective