• IEC 61334-5-1:2001

    Current The latest, up-to-date edition.

    Distribution automation using distribution line carrier systems - Part 5-1: Lower layer profiles - The spread frequency shift keying (S-FSK) profile

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French

    Published date:  28-05-2001

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 General
      1.1 Scope and object
      1.2 Normative references
      1.3 Definitions
    2 Modulation
      2.1 Purpose
      2.2 Spread frequency shift keying (S-FSK) principle
      2.3 Spreading
      2.4 Performance tests
          2.4.1 Purpose
          2.4.2 White noise BER tests
          2.4.3 Narrowband interferer BER tests
          2.4.4 Impulsive noise BER tests
    3 Physical layer
      3.1 Purpose
      3.2 Transmission method
          3.2.1 Coding
          3.2.2 Bit timing
          3.2.3 Frame timing
          3.2.4 Slot timing
      3.3 Packet encapsulation
          3.3.1 Purpose
          3.3.2 Byte and bit ordering
          3.3.3 Preamble and start subframe delimiter
          3.3.4 Pause
      3.4 Physical layer services definitions
          3.4.1 General description
          3.4.2 P_Data.request
          3.4.3 P_Data.confirm
          3.4.4 P_Data.indication
          3.4.5 P_Sync.request
          3.4.6 P_Sync.indication
      3.5 Sending and receiving physical sublayer
          3.5.1 Sending
          3.5.2 Receiving
          3.5.3 Synchronization - desynchronization of a server
          3.5.4 Physical state transition tables
          3.5.5 Transition table description
    4 Medium access control sublayer (MAC)
      4.1 MAC service specification
          4.1.1 Purpose
          4.1.2 Characteristics
          4.1.3 Overview of the services
          4.1.4 MA_Data.request
          4.1.5 MA_Data.confirm
          4.1.6 MA_Data.indication
          4.1.7 MA_Sync.indication
      4.2 MAC frame structure
          4.2.1 Frame indicator
          4.2.2 Long MAC frame format
          4.2.3 Elements of the long MAC frame
          4.2.4 Invalid long MAC frame
      4.3 Medium access control method
          4.3.1 Functional model
          4.3.2 Transmission description
          4.3.3 Reception description
          4.3.4 MAC management description
          4.3.5 Formal specification
          4.3.6 Medium access state table
          4.3.7 Transition table description
    Annex A (normative) Description of error values
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes the requirements of S-FSK (frequency shift keying modulation) in conjunction with the services provided by the physical layer entity and the MAC sublayer. The transmission medium is assumed to be the distribution network on both MV or LV level. To be used in conjunction with IEC 61334-4-32.

    This publication is of high relevance for Smart Grid.

    General Product Information - (Show below) - (Hide below)

    Committee TC 57
    Development Note Also Numbered as BS EN 61334-5-1 (10/2001) Stability Date: 2018. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEC 62056-5-3 REDLINE : 2ED 2016 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 5-3: DLMS/COSEM APPLICATION LAYER
    BS EN 62056-1-0:2015 Electricity metering data exchange. The DLMS/COSEM suite Smart metering standardization framework
    16/30339535 DC : 0 BS EN 62056-5-3 ED 3.0 - ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 5-3: DLMS/COSEM APPLICATION LAYER
    10/30239388 DC : 0 BS EN ISO/IEC 62056-6-2 - ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES
    I.S. EN 62056-8-3:2013 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 8-3: COMMUNICATION PROFILE FOR PLC S-FSK NEIGHBOURHOOD NETWORKS (IEC 62056-8-3:2013 (EQV))
    NF EN 62056-6-2 : 2017 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES
    IEC 62056-5-3:2016 RLV Electricity metering data exchange - The DLMS/COSEM suite - Part 5-3: DLMS/COSEM application layer
    EN 62056-5-3:2017 Electricity metering data exchange - The DLMS/COSEM suite - Part 5-3: DLMS/COSEM application layer
    EN 61334-4-512:2002 Distribution automation using distribution line carrier systems - Part 4-512: Data communication protocols - System management using profile 61334-5-1 - Management Information Base (MIB)
    EN 62056-1-0:2015 Electricity metering data exchange - The DLMS/COSEM suite - Part 1-0: Smart metering standardization framework
    16/30341766 DC : 0 BS EN 62056-6-2 - ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES
    11/30244733 DC : 0 BS EN 62056-8-3 - ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 8-3: THE PLC SFSK PROFILE FOR NEIGHBOURHOOD NETWORKS
    BS EN 62056-5-3:2017 Electrcity metering data exchange. The DLMS/COSEM suite DLMS/COSEM application layer
    BS EN 62056-8-3:2013 Electricity metering data exchange. The DLMS/COSEM suite Communication profile for PLC S-FSK neighbourhood networks
    11/30242642 DC : 0 BS EN 62056-5-3 - ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 5-3: DLMS/COSEM APPLICATION LAYER
    I.S. EN 62056-1-0:2015 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 1-0: SMART METERING STANDARDIZATION FRAMEWORK
    IEC 62056-8-3:2013 Electricity metering data exchange - The DLMS/COSEM suite - Part 8-3: Communication profile for PLC S-FSK neighbourhood networks
    I.S. EN 61334-4-512:2002 DISTRIBUTION AUTOMATION USING DISTRIBUTION LINE CARRIER SYSTEMS - PART 4-512: DATA COMMUNICATION PROTOCOLS - SYSTEM MANAGEMENT USING PROFILE 61334-5-1 - MANAGEMENT INFORMATION BASE (MIB)
    TS 103 901 : 1.1.1 POWERLINE TELECOMMUNICATIONS (PLT); COEXISTENCE OF NARROW BAND PLT TECHNOLOGIES OPERATING IN THE FREQUENCY BANDS 3KHZ TO 95 KHZ, 95 KHZ TO 125 KHZ AND 125 KHZ TO 140 KHZ; [IEEE STD 1901.2TM - 2013, IEEE STANDARD FOR LOW-FREQUENCY (LESS THAN 500 KHZ) NARROWBAND POWER LINE COMMUNICATIONS FOR SMART GRID APPLICATIONS, SECTION 10 COEXISTENCE]
    NF EN 62056-8-3 : 2013 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 8-3: COMMUNICATION PROFILE FOR PLC S-FSK NEIGHBOURHOOD NETWORKS
    UNE-EN 62056-1-0:2016 Electricity metering data exchange - The DLMS/COSEM suite - Part 1-0: Smart metering standardization framework
    EN IEC 62056-6-2:2018 Electricity metering data exchange - The DLMS/COSEM suite - Part 6-2: COSEM interface classes
    14/30301434 DC : 0 BS EN 62056-6-2 AMD 1 - ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES
    CEI EN 62056-6-2 : 2014 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES
    I.S. EN IEC 62056-6-2:2018 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES
    BS EN 62056-6-2:2016 Electricity metering data exchange. The DLMS/COSEM suite COSEM interface classes
    BS EN 61334-4-511:2001 Distribution automation using distribution line carrier systems. Data communication protocols Systems management. CIASE protocol
    BS EN 61334-4-512:2002 Distribution automation using distribution line carrier systems. Data communication protocols System management using profile 61334-5-1. Management Information Base (MIB)
    NF EN 61334 4 511 : 2001 DISTRIBUTION AUTOMATION USING LINE CARRIER SYSTEMS - PART 4-511: DATA COMMUNICATIONS PROTOCOLS - SYSTEMS MANAGEMENT - CIASE PROTOCOL
    CEI EN 61334-4-511 : 2001 DISTRIBUTION AUTOMATION USING DISTRIBUTION LINE CARRIER SYSTEMS - PART 4-511: DATA COMMUNICATION PROTOCOLS - SYSTEMS MANAGEMENT - CIASE PROTOCOL
    IEEE 1901.2-2013 IEEE Standard for Low-Frequency (less than 500 kHz) Narrowband Power Line Communications for Smart Grid Applications
    IEC 62056-1-0:2014 Electricity metering data exchange - The DLMS/COSEM suite - Part 1-0: Smart metering standardisation framework
    IEC 61334-4-512:2001 Distribution automation using distribution line carrier systems - Part 4-512: Data communication protocols - System management using profile 61334-5-1 - Management Information Base (MIB)
    IEC 61334-4-511:2000 Distribution automation using distribution line carrier systems - Part 4-511: Data communication protocols - Systems management - CIASE protocol
    I.S. EN 62056-6-2:2016 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES
    I.S. EN 62056-5-3:2017 ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 5-3: DLMS/COSEM APPLICATION LAYER
    IEC 62056-5-3:2017 Electrcity metering data exchange - The DLMS/COSEM suite - Part 5-3: DLMS/COSEM application layer
    I.S. EN 61334-4-511:2000 DISTRIBUTION AUTOMATION USING DISTRIBUTION LINE CARRIER SYSTEMS - PART 4-511: DATA COMMUNICATION PROTOCOLS - SYSTEMS MANAGEMENT - CIASE PROTOCOL
    EN 61334-4-511:2000 Distribution automation using distribution line carrier systems - Part 4-511: Data communication protocols - Systems management - CIASE protocol
    EN 62056-8-3:2013 Electricity metering data exchange - The DLMS/COSEM suite - Part 8-3: Communication profile for PLC S-FSK neighbourhood networks

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC 7498-3:1997 Information technology Open Systems Interconnection Basic Reference Model: Naming and addressing
    ISO/IEC 7498-1:1994 Information technology Open Systems Interconnection Basic Reference Model: The Basic Model
    IEC TR 61334-1-4:1995 Distribution automation using distribution line carrier systems - Part 1: General considerations - Section 4: Identification of data transmission parameters concerning medium and low-voltage distribution mains
    IEC 61334-4-32:1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 32: Data link layer - Logical link control (LLC)
    IEC 61334-4-511:2000 Distribution automation using distribution line carrier systems - Part 4-511: Data communication protocols - Systems management - CIASE protocol
    EN 50065-1:2011 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances
    IEC 61334-4-1:1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 1: Reference model of the communication system
    IEC 61334-4-512:2001 Distribution automation using distribution line carrier systems - Part 4-512: Data communication protocols - System management using profile 61334-5-1 - Management Information Base (MIB)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective