    Clause
    1 General
        1.1 Scope
        1.2 Service conditions
    2 Normative references
    3 Definitions
    4 List of variables
    5 Ratings
        5.1 General
        5.2 Rated voltage
        5.3 Rated current
        5.4 Rated frequency
        5.5 Rated power
    6 Tolerances
        6.1 General
        6.2 Short-circuit impedance tolerances
        6.3 Guarantees
    7 Losses
        7.1 General
        7.2 No-load loss
        7.3 Load loss under rated power-frequency conditions
        7.4 Determination of hot-spot temperature
    8 Insulation levels
        8.1 Line windings
        8.2 Valve windings
        8.3 Induced voltage level with partial discharge measurements
    9 Sound level
        9.1 General
        9.2 Guaranteed sound-power levels
        9.3 Sound-power level at site
    10 Testing
        10.1 General
        10.2 Tests
        10.3 Load-loss measurements
        10.4 Factory dielectric tests
        10.5 Temperature-rise test
        10.6 Load-current test
        10.7 Determination of transformer sound-power level
    11 High-frequency modelling
    12 Loading of transformer above rating
    13 Bushings
        13.1 AC bushings
        13.2 Valve winding bushings
    14 Tap-changer
        14.1 General
        14.2 Current wave shape
    Bibliography

    Abstract - (Show below) - (Hide below)

    This part of IEC 61378 applies to oil-immersed three-phase and -single-phase convertor transformers for use in HVDC power transmission. It applies to transformers having two, three or multiple windings. This standard does not apply to convertor transformers for industrial applications (see IEC 61378-1) and to convertor transformers for traction applications (see IEC 60310).

    General Product Information - (Show below) - (Hide below)

    Committee TC 14
    Development Note Also numbered as BS EN 61378-2 (06/2001) Stability Date: 2017. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS IEC 60076-15:2015 Power transformers Gas-filled power transformers
    CEI EN 60076-14 : 2014 POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
    BS IEC/IEEE 65700-19-03 : 2014 BUSHINGS FOR DC APPLICATION
    12/30263868 DC : 0 BS EN 60076-14 - POWER TRANSFORMERS - PART 14: LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
    BS EN 60076-6:2008 Power transformers Reactors
    I.S. EN 60076-14:2013 POWER TRANSFORMERS - PART 14: LIQUIDIMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS (IEC 60076-14:2013 (EQV))
    IEC TS 60076-14:2009 Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials
    EN 61378-1:2011 Convertor transformers - Part 1: Transformers for industrial applications
    BS EN 60076-14:2013 Power transformers Liquid-immersed power transformers using high-temperature insulation materials
    BS IEC 61378-3:2015 Converter transformers Application guide
    UNE-EN 60076-14:2014 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
    CEI 14-42 : 2011 CONVERTER TRANSFORMERS - PART 3: APPLICATION GUIDE
    IEC 61378-3:2015 Converter transformers - Part 3: Application guide
    CEI EN 61378-1 : 2012 CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS
    I.S. EN 60146-1-1:2010 SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS
    I.S. EN 61803:1999 DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE COMMUTATED CONVERTERS
    IEC/IEEE 65700-19-03:2014 Bushings for DC application
    BS EN 61803 : 1999 DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE-COMMUTATED CONVERTERS (IEC 61803:1999)
    CEI EN 61803 : 2011 DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS
    05/30133866 DC : DRAFT MAY 2005 IEC 60076-6 - POWER TRANSFORMERS - PART 6: REACTORS
    I.S. EN 60076-6:2008 POWER TRANSFORMERS - PART 6: REACTORS
    DD IEC TS 60076-14 : DRAFT 2009 POWER TRANSFORMERS - PART 14: DESIGN AND APPLICATION OF LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
    02/211941 DC : 0 IEC 60076-14 ED.1 - GUIDE FOR THE DESIGN AND APPLICATION OF LIQUID-IMMERSED POWER TRANSFORMERS USING HIGH-TEMPERATURE INSULATION MATERIALS
    10/30232718 DC : 0 BS EN 60076-3 - POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR
    BS EN 61378-1:2011 Convertor transformers Transformers for industrial applications
    EN IEC/IEEE 65700 : 2018 BUSHINGS FOR DC APPLICATION (IEC/IEEE 65700-19-03:2014)
    BS EN 60076-1:2011 Power transformers General
    09/30206330 DC : 0 BS EN 61803:1999+A1 - DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS
    CEI EN 60076-1 : 2015 POWER TRANSFORMERS - PART 1: GENERAL
    CEI EN 60146-1-1 : 2013 SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS
    CEI EN 60076-6 : 2015 POWER TRANSFORMERS - PART 6: REACTORS
    IEC 60076-15:2015 Power transformers - Part 15: Gas-filled power transformers
    EN 61803:1999/A2:2016 DETERMINATION OF POWER LOSSES IN HIGH-VOLTAGE DIRECT CURRENT (HVDC) CONVERTER STATIONS WITH LINE COMMUTATED CONVERTERS (IEC 61803:1999/A2:2016)
    IEC 61378-1:2011 Converter transformers - Part 1: Transformers for industrial applications
    UNE-EN 60076-1:2013 Power transformers - Part 1: General
    IEC 60076-6:2007 Power transformers - Part 6: Reactors
    IEC 60146-1-1:2009 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
    IEC 61803:1999+AMD1:2010+AMD2:2016 CSV Determination of power losses in high-voltage direct current (HVDC)converter stations with line-commutated converters
    IEC 60076-1:2011 Power transformers - Part 1: General
    IEC 60076-14:2013 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
    06/30156472 DC : DRAFT SEP 2006 BS EN 60146-1-1 - SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS
    BS EN 60146-1-1:2010 Semiconductor converters. General requirements and line commutated converters Specification of basic requirements
    C88-16 Power transformers and reactors
    IEEE C57.129-2007 REDLINE IEEE Standard for General Requirements and Test Code for Oil-Immersed HVDC Converter Transformers
    I.S. EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
    I.S. EN IEC/IEEE 65700:2018 BUSHINGS FOR DC APPLICATION
    I.S. EN 61378-1:2011 CONVERTOR TRANSFORMERS - PART 1: TRANSFORMERS FOR INDUSTRIAL APPLICATIONS (IEC 61378-1:2011)
    EN 60076-6:2008 Power transformers - Part 6: Reactors
    EN 60146-1-1:2010 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
    EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
    EN 60076-14:2013 Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
    IEC 60214:1989 On-load tap-changers
    IEC 60076-10:2016 Power transformers - Part 10: Determination of sound levels
    IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
    IEC 60567:2011 Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance
    IEC 60354:1991 Loading guide for oil-immersed power transformers
    IEC 60076-8:1997 Power transformers - Part 8: Application guide
    IEC 60146-1-1:2009 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
    IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
    IEC TR 60146-1-2:2011 Semiconductor converters - General requirements and line commutated converters - Part 1-2: Application guide
    IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
    IEC 60076-1:2011 Power transformers - Part 1: General
    IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
    IEC 61378-1:2011 Converter transformers - Part 1: Transformers for industrial applications
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective