• IEC 62013-1:2005

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Caplights for use in mines susceptible to firedamp - Part 1: General requirements - Construction and testing in relation to the risk of explosion

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  26-05-2011

    Language(s):  English - French, Spanish, Castilian

    Published date:  24-10-2005

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General
       4.1 Enclosures
       4.2 Internal electrical connections
       4.3 Solid electrical insulating
       4.4 Internal wiring
       4.5 Surface temperature
       4.6 Supply of electrical power to another apparatus
       4.7 Creepage and clearance distances
       4.8 Assembled electrical connection
    5 Overcurrent protection
    6 Headpiece
    7 Battery
    8 Cable
    9 External charging contacts
    10 Type verifications and tests
       10.1 General
       10.2 Impact test
       10.3 Drop tests
       10.4 Test to verify the protection against ingress
             of dust and water
       10.5 Test to verify the non-ignition of a
             representative electrolytic gas mixture or
             firedamp by fuse or thermal circuit-breaker
       10.6 Test to verify the non-ignition of a gas mixture
             by one strand of the cable between the headpiece
             and the battery by thermal ignition
       10.7 Test to verify the resistance of the cable sheath
             to fatty acids
       10.8 Test to verify the resistance of the cable sheath
             to fire
       10.9 Test to verify the strength of cable entries,
             anchoring devices and cable
       10.10 Spark ignition test
       10.11 Electrolyte leakage test
       10.12 Current-limiting resistor test
    11 Marking
    12 Instructions

    Abstract - (Show below) - (Hide below)

    This part of IEC 62013 specifies requirements for the construction and testing of caplights, including caplights with a point of connection for another apparatus, for use in mines susceptible to firedamp (Group I - electrical apparatus for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition.

    General Product Information - (Show below) - (Hide below)

    Committee TC 31
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    CSA C22.2 No. 60079.0 : 2015 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
    IEC 60079-7:2015+AMD1:2017 CSV Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
    EN IEC 60079-7:2015/A1:2018 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017)
    EN 62013-2:2006 Caplights for use in mines susceptible to firedamp - Part 2: Performance and other safety-related matters
    03/300201 DC : DRAFT FEB 2003 IEC 60079-0 ED.4.0 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
    03/313427 DC : DRAFT NOV 2003 IEC 62013-2 - CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - PART 2: PERFORMANCE AND OTHER SAFETY-RELATED MATTERS
    04/30113660 DC : DRAFT MAY 2004 IEC 60079-7 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY 'E'
    BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
    CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
    09/30206527 DC : 0 BS EN 60079-0 ED 6.0 - EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
    BIS IS/IEC 60079-0 : 2011 EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
    I.S. EN 60079-11:2012 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'
    ISA 60079-7 : 2008 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E"
    14/30278882 DC : 0 BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
    I.S. EN 62013-2:2006 CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - PART 2: PERFORMANCE AND OTHER SAFETY-RELATED MATTERS
    IEC 60079-11:2011 RLV Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    IEC 62013-2:2005 Caplights for use in mines susceptible to firedamp - Part 2: Performance and other safety-related matters
    IEC 60079-11 REDLINE : 6.0 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'
    UNE-EN 60079-11:2013 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    PD CEN/TR 16149:2011 Guidance Document for drafting CEN/TC 158 Standards
    BS EN 62013-2:2006 Caplights for use in mines susceptible to firedamp Performance and other safety-related matters
    IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    BS EN 60079-11:2012 Explosive atmospheres Equipment protection by intrinsic safety \'i\'
    UNE-EN 60079-0:2013 Explosive atmospheres - Part 0: Equipment - General requirements
    05/30134569 DC : DRAFT JUN 2005 IEC 60079-0. ED. 5.0 - ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
    I.S. EN 60079-0:2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011 (MOD))
    CSA E60079.7 : 2003 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY "E"
    BIS IS/IEC 60079-7 : 2006 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
    I.S. EN 60079-7:2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
    BS EN 60079-0 : 2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
    UNE-EN 60079-7:2016 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
    CSA C22.2 No. 60079-11 : 2014 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'
    EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
    CEN/TR 16149:2011 Guidance Document for drafting CEN/TC 158 Standards
    EN 60079-11:2012 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
    IEC TR 60079-20:1996 Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus
    IEC 60332-1:1993 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
    IEC 60050-845:1987 International Electrotechnical Vocabulary (IEV) - Part 845: Lighting
    IEC 60127-2:2014 Miniature fuses - Part 2: Cartridge fuse-links
    IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective