• IEC 62271-2:2003

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  23-08-2007

    Language(s):  English - French, Spanish, Castilian

    Published date:  11-02-2003

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope and object
    2 Normative references
    3 Definitions
    4 Seismic qualification requirements
      4.1 Preliminary analysis
    5 Severities
    6 Qualification by test
      6.1 Introduction
      6.2 Mounting
      6.3 External load
      6.4 Measurements
      6.5 Frequency range
      6.6 Test severity
      6.7 Testing
    7 Qualification by combined test and analysis
      7.1 Introduction
      7.2 Vibrational and functional data
      7.3 Analysis
    8 Evaluation of the seismic qualification
      8.1 Combination of stresses
      8.2 Acceptance criteria of the seismic test
      8.3 Functional evaluation of the test results
      8.4 Allowable stresses
    9 Documentation
      9.1 Information for seismic qualification
      9.2 Test report
      9.3 Analysis report
    Annex A (normative) - Characterization of the test-set
    Annex B (informative) - Criteria for seismic adequacy of
                            gas-insulated metal-enclosed
                            switchgear
    Bibliography
    Figures
    Tables

    Abstract - (Show below) - (Hide below)

    Applies to all switchgear and their assemblies for alternating current of rated voltages of 72,5 kV and above for indoor and outdoor installation, including their supporting structure rigidly connected to the ground.Where switchgear and their assemblies are not ground mounted, e.g. in a building, conditions for application are subject to agreement between users and manufacturers.The seismic qualification of the switchgear and their assemblies take into account any auxiliary and control equipment either directly mounted or as a separate structure. This standard provides procedures to seismically qualify ground mounted switchgear and their assemblies for rated voltages of 72,5 kV and above.The seismic qualification of the switchgear and their assemblies is only performed upon request.This standard specifies seismic severity levels and gives a choice of methods that may be applied to demonstrate the performance of high-voltage switchgear and their assemblies for which seismic qualification is required.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNE-EN 62271-205:2011 High-voltage switchgear and controlgear -- Part 205: Compact switchgear assemblies for operation at rated voltages above 52 kV
    BS EN 61869-1:2009 Instrument transformers General requirements
    EN 62271-205:2008/corrigendum:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
    NF EN 61869-1 : 2009 INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    CSA C61869-1 : 2014 INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    BIS IS/IEC 62271-1 : 2007 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS
    I.S. EN 62271-205:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
    UNE-EN 61869-1:2010 Instrument transformers -- Part 1: General requirements
    I.S. EN 61869-1:2009 INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    IEEE/IEC C37.60-2012 IEEE/IEC International Standard - High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
    CEI EN 62271-205 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
    IEC 62271-111:2012 High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
    IEC 62271-205:2008 High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV
    BS EN 62271-205:2008 High-voltage switchgear and controlgear Compact switchgear assemblies for rated voltages above 52 kV
    CEI EN 61869-1 : 2010 INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    IEC 61869-1:2007 Instrument transformers - Part 1: General requirements
    EN 61869-1:2009 Instrument transformers - Part 1: General requirements

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
    IEC 60068-2-57:2013 Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method
    IEC 60068-3-3:1991 Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments
    IEC 60517:1990 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
    IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
    IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
    IEEE 693-2005 IEEE Recommended Practice for Seismic Design of Substations
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective