• IEEE 400.2-2013 REDLINE

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz)

    Available format(s):  PDF

    Withdrawn date:  21-03-2024

    Language(s):  English

    Published date:  09-06-2013

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. Overview
    2. Normative references
    3. Definitions, acronyms, and abbreviations
    4. Safety
    5. Very low frequency (VLF) ac testing
    6. Conclusions
    Annex A (informative) - Bibliography
    Annex B (normative) - Wave shapes of VLF ac voltage
            testing voltages
    Annex C (informative) - Typical defects in fluid-filled
            and extruded cable systems
    Annex D (informative) - Effect of initial increase in
            voltage (ramp up)
    Annex E (informative) - Figures of merit and range of
            available tangent delta and differential tangent
            delta (tip up) data
    Annex F (informative) - Comments on data interpretation
            and performance
    Annex G (informative) - Tan delta results of new cable
            systems
    Annex H (informative) - Development of utility/application
            specific criteria
    Annex I (informative) - Tangent delta criteria used outside
            North America

    Abstract - (Show below) - (Hide below)

    Specifies VLF withstand and other diagnostic tests and the measurements that are performed in the field on service-aged shielded medium and high-voltage cables rated 5 kV through 69 kV with extruded and laminated insulation.

    General Product Information - (Show below) - (Hide below)

    Committee Insulated Conductors
    Development Note Supersedes IEEE DRAFT 400.2. (03/2005) Also included in IEEE 400 Set (CD-ROM) dated 28/11/2012 with IEEE 400, IEEE 400.1 and IEEE 400.3. Also included in IEEE 400 Series dated 05/10//2013 with IEEE 400, IEEE 400.1 and IEEE 400.3. (10/2013)
    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Withdrawn
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEEE 1242-1999 IEEE Guide for Specifying and Selecting Power, Control, and Special-Purpose Cable for Petroleum and Chemical Plants
    BS EN 62271-200:2012 High-voltage switchgear and controlgear AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    CSA C293.2 : 2017 STANDARD FOR SKIN EFFECT TRACE HEATING OF PIPELINES, VESSELS, EQUIPMENT, AND STRUCTURES - APPLICATION GUIDE FOR DESIGN, INSTALLATION, TESTING, COMMISSIONING, AND MAINTENANCE
    NFPA 70B : 2016 RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE
    EN 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    EN 60505:2011/AC:2017-03 EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS (IEC 60505:2011/COR1:2017)
    IEEE 844.2/CSA C293.2-2017 IEEE/CSA Standard for Skin Effect Trace Heating of Pipelines, Vessels, Equipment, and Structures--Application Guide for Design, Installation, Testing, Commissioning, and Maintenance
    I.S. EN 60505:2011 EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS
    NETA ATS : 2017 ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
    CEI EN 62271-201 : 2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
    UNE-EN 62271-200:2012 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    12/30253935 DC : DRAFT JUNE 2012 BS EN 62271-201 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - AC SOLID-INSULATED ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
    IEEE 400-2012 REDLINE IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above
    IEEE 3007.2 : 2010 This recommended practice covers the maintenance of industrial and commercial power systems.
    I.S. EN 62271-200:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011 (EQV))
    EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
    IEC 62271-111:2012 High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
    IEEE/IEC C37.60-2012 IEEE/IEC International Standard - High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
    BS EN 60505:2011 Evaluation and qualification of electrical insulation systems
    IEEE 1205-2014 IEEE Guide for Assessing, Monitoring, and Mitigating Aging Effects on Electrical Equipment Used in Nuclear Power Generating Stations and Other Nuclear Facilities
    UNE-EN 62271-201:2015 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    IEC 60505:2011 Evaluation and qualification of electrical insulation systems
    IEEE 1185-2010 IEEE Recommended Practice for Cable Installation in Generating Stations and Industrial Facilities
    IEEE 400.4-2015 IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage
    BS EN 62271-201:2014 High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    IEEE 422-2012 IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities
    IEEE C37.63-2013 REDLINE IEEE Standard Requirements for Overhead, Pad-Mounted, Dry-Vault, and Submersible Automatic Line Sectionalizers for Alternating Current Systems Up to 38 kV
    IEEE 2030.2-2015 IEEE Guide for the Interoperability of Energy Storage Systems Integrated with the Electric Power Infrastructure
    I.S. EN 62271-201:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
    IEC 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    IEEE 400.3-2022 IEEE Guide for Partial Discharge Field Diagnostic Testing of Shielded Power Cable Systems

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
    NETA ATS : 2017 ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
    IEC 60885-3:2015 RLV Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
    NETA MTS : 2011 MAINTENANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
    IEEE 1617:2007 DETECTION, MITIGATION, AND CONTROL OF CONCENTRIC NEUTRAL CORROSION IN MEDIUM-VOLTAGE UNDERGROUND CABLES
    NFPA 70E : 2018 ELECTRICAL SAFETY IN THE WORKPLACE
    IEC 60060-3:1976 High-voltage test techniques - Part 3: Measuring devices
    IEC 61230:2008 Live working - Portable equipment for earthing or earthing and short-circuiting
    IEEE 400-2012 REDLINE IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective