• IEEE C37.011-2011

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    GUIDE FOR THE APPLICATION OF TRANSIENT RECOVERY VOLTAGE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS

    Available format(s):  Hardcopy, PDF

    Superseded date:  15-10-2018

    Language(s):  English

    Published date:  01-01-2011

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Overview
    2 Normative references
    3 Transient recovery voltage
    4 Application considerations
    Annex A (informative) - TRV calculation techniques
    Annex B (informative) - Typical capacitance values for various
            equipment
    Annex C (informative) - Selection of the first pole-to-clear
            factors and factors for the second and third pole to clear
    Annex D (informative) - Bibliography

    Abstract - (Show below) - (Hide below)

    Provides procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS IEC/IEEE 62271-37-013:2015 High-voltage switchgear and controlgear Alternating-current generator circuit-breakers
    14/30257408 DC : 0 BS IEC/IEEE 62271-37-013 ED 1.0 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 37-013: ALTERNATING-CURRENT GENERATOR CIRCUIT-BREAKERS
    ANSI C37.06 : 2009 AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES
    IEEE C37.100.2 : 2018 COMMON REQUIREMENTS FOR TESTING OF AC CAPACITIVE CURRENT SWITCHING DEVICES OVER 1000 V
    IEEE DRAFT C37.06 : D6 2004 AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES
    IEEE C37.010 : 1999 AC HIGH-VOLTAGE CIRCUIT BREAKERS > 1000 VAC RATED ON A SYMMETRICAL CURRENT BASIS
    IEC TR 62271-306:2012 High-voltage switchgear and controlgear - Part 306: Guide to IEC 62271-100, IEC 62271-1 and other IEC standards related to alternating current circuit-breakers
    NEMA SG 4:2009(R2013) ALTERNATING CURRENT HIGH-VOLTAGE CIRCUIT BREAKERS
    IEEE/IEC 62271-37-013-2015 IEEE/IEC International Standard for High-voltage switchgear and controlgear -- Part 37-013: Alternating-current generator circuit-breakers
    IEEE C37.04 : 1999 IEEE STANDARD RATING STRUCTURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS
    IEEE C37.06-2009 IEEE Standard for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis--Preferred Ratings and Related Required Capabilities for Voltages Above 1000 V
    IEEE DRAFT C37.09 : D03F JAN 99 TEST PROCEDURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS
    IEEE C37.06.1 : 2017 PREFERRED RATINGS FOR HIGH-VOLTAGE (>1000 VOLTS) AC CIRCUIT BREAKERS DESIGNATED DEFINITE PURPOSE FOR FAST TRANSIENT RECOVERY VOLTAGE RISE TIMES
    IEEE C37.122.1-2014 REDLINE IEEE Guide for Gas-Insulated Substations Rated Above 52 kV
    IEEE 3001.5 : 2013 RECOMMENDED PRACTICE FOR THE APPLICATION OF POWER DISTRIBUTION APPARATUS IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS
    IEEE C37.016 : 2006 AC HIGH-VOLTAGE CIRCUIT SWITCHERS RATED 15.5 KV THROUGH 245 KV
    IEEE C37.10 : 2011 GUIDE FOR INVESTIGATION, ANALYSIS, AND REPORTING OF POWER CIRCUIT BREAKER FAILURES
    IEEE C37.12 : 2008 SPECIFICATIONS OF HIGH-VOLTAGE CIRCUIT BREAKERS (OVER 1000 VOLTS)
    IEEE C37.123 : 1996 SPECIFICATIONS FOR HIGH-VOLTAGE GAS-INSULATED SUBSTATIONS RATED 52 KV AND ABOVE
    IEEE 1147 : 2005 GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS
    IEEE DRAFT C37.10 : D10 JUN 95 DIAGNOSTIC AND FAILURE INVESTIGATION OF POWER CIRCUIT BREAKERS
    IEEE C62.92.3-2012 REDLINE IEEE Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part III -Generator Auxiliary Systems
    IEEE C37.09 : 1999 TEST PROCEDURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEEE C37.04B : 2008 RATING STRUCTURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - AMENDMENT 2: TO CHANGE THE DESCRIPTION OF TRANSIENT RECOVERY VOLTAGE FOR HARMONIZATION WITH IEC 62271-100
    IEEE C37.010 : 1999 AC HIGH-VOLTAGE CIRCUIT BREAKERS > 1000 VAC RATED ON A SYMMETRICAL CURRENT BASIS
    IEEE C37.09 : 1999 TEST PROCEDURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS
    IEEE C37.04 : 1999 IEEE STANDARD RATING STRUCTURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS
    IEEE C37.06-2009 IEEE Standard for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis--Preferred Ratings and Related Required Capabilities for Voltages Above 1000 V
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective