• MIL-PRF-39014 Revision J:2016

    Current The latest, up-to-date edition.

    Capacitor, Fixed, Ceramic Dielectric (General Purpose), Established Reliability and Non-Established Reliability, General Specification for

    Available format(s):  PDF

    Language(s): 

    Published date:  13-06-2016

    Publisher:  US Military Specs/Standards/Handbooks

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. SCOPE
    2. APPLICABLE DOCUMENTS
    3. REQUIREMENTS
    4. VERIFICATION
    5. PACKAGING
    6. NOTES
    APPENDIX A - PROCEDURE FOR QUALIFICATION INSPECTION

    Abstract - (Show below) - (Hide below)

    Specifies the general requirements for established reliability (ER) and non-established reliability (non-ER), (product level C), general purpose, ceramic dielectric, insulated, fixed capacitors for use in applications where appreciable variations in capacitance with respect to temperature, voltage, frequency, and life can be tolerated.

    Scope - (Show below) - (Hide below)

    This specification covers the general requirements for established reliability (ER) and non-established reliability (non-ER), (product level C), general purpose, ceramic dielectric, insulated, fixed capacitors for use in applications where appreciable variations in capacitance with respect to temperature, voltage, frequency, and life can be tolerated (see 6.1). ER capacitors covered by this specification have failure rate levels (FRL) (M, P, R, and S) ranging from 1.0 percent to 0.001 percent per 1,000 hours. These FRLs are established at a 90-percent confidence level and maintained at a 10-percent producer\'s risk and are based on life tests performed at maximum rated voltage at maximum rated temperature. An acceleration factor of 8:1 has been used to relate life test data obtained at 200 percent of rated voltage at maximum rated temperature, to rated voltage at rated temperature.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes MIL C 39014 and MIL R 39014 (10/2002)
    Document Type Standard
    Publisher US Military Specs/Standards/Handbooks
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    MIL-DTL-15514 Revision G:2016 TELEPHONE EQUIPMENT, SOUND POWERED TELEPHONE HANDSET, HEADSET - CHEST SET, AND HEADSET - CHEST SET, NOISE ATTENUATING
    18/30373170 DC : 0 BS EN 62668-2 - PROCESS MANAGEMENT FOR AVIONICS - COUNTERFEIT PREVENTION - PART 2: MANAGING ELECTRONIC COMPONENTS FROM NON-FRANCHISED SOURCES
    MIL-STD-1580 Revision B:2003 DESTRUCTIVE PHYSICAL ANALYSIS FOR ELECTRONIC, ELECTROMAGNETIC, AND ELECTROMECHANICAL PARTS
    MIL-DTL-917 Revision F:2014 ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR
    MIL-PRF-39014-2 Revision L:2004 CAPACITORS, FIXED, CERAMIC DIELECTRIC (GENERAL PURPOSE), ESTABLISHED RELIABILITY AND NONESTABLISHED RELIABILITY, STYLE CKRO6, NATO TYPE DESIGNATION NCC62
    NASA MSFC STD 3012 : 2012 ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL (EEE) PARTS MANAGEMENT AND CONTROL REQUIREMENTS FOR MSFC SPACE FLIGHT HARDWARE
    MIL-C-11015 Revision F:2008 CAPACITOR, FIXED, CERAMIC DIELECTRIC (GENERAL PURPOSE), GENERAL SPECIFICATION FOR
    MIL-PRF-39014-22 Revision F:2011 CAPACITORS, FIXED, CERAMIC DIELECTRIC (GENERAL PURPOSE), ESTABLISHED RELIABILITY, STYLES CKR22, CKR23, AND CKR24
    MIL-PRF-39014-23 Revision B:2006 CAPACITORS, FIXED, CERAMIC DIELECTRIC (GENERAL PURPOSE) ESTABLISHED RELIABILITY, STYLE CKR04
    MIL-PRF-39014-1 Revision H:2004 CAPACITORS, FIXED, CERAMIC DIELECTRIC (GENERAL PURPOSE), ESTABLISHED RELIABILITY AND NONESTABLISHED RELIABILITY, STYLE CKRO5, NATO TYPE DESIGNATION NCC61
    IEC TS 62668-2:2016 Process management for avionics - Counterfeit prevention - Part 2: Managing electronic components from non-franchised sources
    PD IEC/TS 62668-2:2016 Process management for avionics. Counterfeit prevention Managing electronic components from non-franchised sources
    MIL-HDBK-198 Revision B:2012 CAPACITORS, SELECTION AND USE OF
    MIL-O-52374 Revision E:2013 Oscillator: High Voltage General Specification for

    Standards Referencing This Book - (Show below) - (Hide below)

    MIL-STD-202-211 Base Document:2015 METHOD 211, TERMINAL STRENGTH
    MIL-STD-202-302 Base Document:2015 METHOD 302, INSULATION RESISTANCE
    MIL-STD-810 Revision G:2008 ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS
    MIL-STD-202-210 Base Document:2015 METHOD 210, RESISTANCE TO SOLDERING HEAT
    MIL-STD-1276 Revision H:2013 Leads for Electronic Component Parts
    MIL-STD-202-305 Base Document:2015 METHOD 305, CAPACITANCE
    MIL-STD-202-209 Base Document:2015 METHOD 209, RADIOGRAPHIC INSPECTION
    MIL-STD-202-101 Base Document:2015 METHOD 101, SALT ATMOSPHERE (CORROSION)
    MIL-STD-202-107 Base Document:2015 METHOD 107, THERMAL SHOCK
    MIL-STD-202-106 Base Document:2015 METHOD 106, MOISTURE RESISTANCE
    MIL-STD-202-301 Base Document:2015 METHOD 301, DIELECTRIC WITHSTANDING VOLTAGE
    MIL-STD-202-215 Base Document:2015 METHOD 215, RESISTANCE TO SOLVENTS
    MIL-STD-790 Revision G:2011 ESTABLISHED RELIABILITY AND HIGH RELIABILITY QUALIFIED PRODUCTS LIST (QPL) SYSTEMS FOR ELECTRICAL, ELECTRONIC, AND FIBER OPTIC PARTS SPECIFICATIONS
    MIL-STD-202-104 Base Document:2015 METHOD 104, IMMERSION
    MIL-STD-202-108 Base Document:2015 METHOD 108, LIFE (AT ELEVATED AMBIENT TEMPERATURE)
    MIL-STD-202-105 Base Document:2015 METHOD 105, BAROMETRIC PRESSURE (REDUCED)
    MIL-STD-202-208 Base Document:2015 METHOD 208, SOLDERABILITY
    MIL-STD-202 Revision H:2015 ELECTRONIC AND ELECTRICAL COMPONENT PARTS
    MIL-STD-690 Revision D:2005 Failure Rate (FR) Sampling Plans and Procedures
    MIL-STD-202-204 Base Document:2015 METHOD 204, VIBRATION, HIGH FREQUENCY
    MIL-STD-202-213 Base Document:2015 METHOD 213, SHOCK (SPECIFIED PULSE)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective