• MIL-PRF-83536 Revision F:2017

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 25 AMPERES AND BELOW, GENERAL SPECIFICATION FOR

    Available format(s):  PDF

    Superseded date:  30-04-2021

    Language(s): 

    Published date: 

    Publisher:  US Military Specs/Standards/Handbooks

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. SCOPE
    2. APPLICABLE DOCUMENTS
    3. REQUIREMENTS
    4. VERIFICATION
    5. PACKAGING
    6. NOTES

    Abstract - (Show below) - (Hide below)

    Specifies the general requirements for electromagnetic, hermetically sealed relays for use in aircraft, missile, spacecraft, ship, and other primary vehicles or in ground support equipment.

    General Product Information - (Show below) - (Hide below)

    Committee FSC 5945
    Document Type Standard
    Publisher US Military Specs/Standards/Handbooks
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    MIL-PRF-83536-20 Revision A:2004 Relays, Electromagnetic, Established Reliability, 4PDT, Low Level to 10 Amperes, Magnetic Latch, Hermetically Sealed, All Welded, AC Coils (No S/S Document)
    MIL-STD-1580 Revision B:2003 DESTRUCTIVE PHYSICAL ANALYSIS FOR ELECTRONIC, ELECTROMAGNETIC, AND ELECTROMECHANICAL PARTS
    MIL-DTL-12883-45 Revision D:2003 Sockets, Plug-In Electronic Components, for Relays, for 2-Pole, 5 Amperes (MIL-PRF-6106 and MIL-PRF-83536)
    MIL-PRF-83536-18 Revision D:2017 Relays, Electromagnetic, Established Reliability, 4PDT, Low Level to 10 Amperes, Magnetic Latch, Hermetically Sealed, all Welded, DC Coils
    MIL STD 11991 : A GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES
    MIL-PRF-83536-2 Revision C:2016 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 5 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COILS
    DSCC 86087 : E RELAYS, ELECTROMAGNETIC, PERMANENT MAGNET DRIVE, 4PDT, LOW LEVEL TO 5 AMPERES, ALL WELDED, HERMETICALLY SEALED (SIMILAR TO MIL-R-6106/28 EXCEPT FOR 12V DC COIL AND INVERTED STUD MOUNT)
    MIL-PRF-83536-8 Revision B:2015 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 4PDT, LOW LEVEL TO 5 AMPERES, PERMANENT MAGNET DRIVE, MAGNETIC LATCH, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COILS
    MIL-PRF-83536-32 Revision D:2017 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 3PDT, 25 AMPERES (RESISTIVE), PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, DC COIL
    MIL-PRF-83536-35 Revision B:2017 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 1PDT, LOW LEVEL TO 10 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED ALL WELDED, TRANSIENT SUPPRESSED DC COIL
    MIL-PRF-6106-20 Revision D:2011 RELAYS, ELECTROMAGNETIC, MAGNETIC LATCH, 25 AMPERES, SPDT, HERMETICALLY SEALED
    MIL-PRF-83536-34 Revision A:1999 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 1PDT, LOW LEVEL TO 10 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED ALL WELDED, DC COIL
    MIL-DTL-12883-50 Revision B:2003 Sockets and Accessories for Plug-in Electronic Components, Brackets and Socket Assembly for Relays, 2-Pole, 10 Amperes (MIL-PRF-6106 and MIL-PRF-83536)
    MIL-R-83726-12 Revision F:2016 RELAYS, HYBRID, TIME DELAY (ON RELEASE), TYPE 2A, CLASS B, 10 AMPERES, 4PDT, HERMETICALLY SEALED, FIXED TIME, 0.100 TO 300 SECONDS
    MIL-PRF-83536-23 Revision B:2016 Relays, Electromagnetic, Established Reliability, 3PDT, Low Level to 10 Amperes, Permanent Magnetic Drive, Magnetic Latch, Hermetically Sealed, all Welded, DC Coil
    MIL-PRF-83536-13 Revision C:2013 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 10 Amperes, Magnetic Latch, Hermetically Sealed, all Welded, Transient Suppressed DC Coils
    DSCC 04054 : 0 RELAYS, ELECTROMAGNETIC, 25 AMPERES, 3 PDT, CONTINUOUS DUTY, HERMETICALLY SEALED, PERMANENT MAGNET DRIVE, AC COIL
    SAE AS 5363 : 2016 ELECTROMECHANICAL POWER CONTROLLER/RELAY, GENERAL SPECIFICATION FOR
    MIL-PRF-83536-19 Revision B:2013 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 4PDT, LOW LEVEL TO 10 AMPERES, MAGNETIC LATCH, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COILS
    MIL-PRF-83536-14 Revision A:2004 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 10 Amperes, Magnetic Latch, Hermetically Sealed, all Welded, AC Coil (No S/S Document)
    MIL-DTL-12883-41 Revision F:2003 SOCKETS, PLUG-IN ELECTRONIC COMPONENTS, FOR RELAYS, 2-POLE, 10 AMPERES (MIL-PRF-6106 AND MIL-PRF-83536)
    MIL-PRF-83536-4 Revision C:2014 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 5 AMPERES, PERMANENT MAGNET DRIVE, MAGNETIC LATCH, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COILS
    MIL-DTL-12883-52 Revision B:2003 Sockets and Accessories for Plug-in Electronic Components Socket Assembly for Relays, 2, 3, and 4-Pole, Track Mount (MIL-PRF-6106, MIL-PRF-83536, and MIL-PRF-83726)
    MIL-PRF-83536-25 Revision B:2016 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 6PDT, LOW LEVEL TO 10 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, DC COIL
    MIL-R-83726-18 Revision H:2016 RELAYS, HYBRID, TIME DELAY (ON RELEASE), TRACK MOUNTED, TYPE 2A, CLASS B, 10 AMPERES, 2PDT, HERMETICALLY SEALED, FIXED TIME, 0.1 TO 300 SECONDS
    MIL-PRF-83536-33 Revision D:2017 Relays, Electromagnetic, Established Reliability, 3PDT, 25 Amperes (Resistive), Permanent Magnet Drive, Hermetically Sealed, all Welded, Transient Suppressed DC Coil
    MIL-PRF-83536-1 Revision B:2011 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 5 Amperes, Permanent Magnet Drive, Hermetically Sealed, all Welded, DC Coils
    MIL-PRF-83536-21 Revision C:2016 Relays, Electromagnetic, Established Reliability, 3PDT, Low Level to 10 Amperes, Permanent Magnetic Drive, Hermetically Sealed, all Welded, DC Coil
    MIL-DTL-12883-44 Revision D:2003 SOCKETS, PLUG-IN ELECTRONIC COMPONENTS, SOCKET FOR RELAYS, 4-POLE, 5 AMPERES (MIL-PRF-6106 AND MIL-PRF-83536)
    MIL-DTL-12883-46 Revision D:2003 SOCKETS, PLUG-IN ELECTRONIC COMPONENTS, FOR RELAYS, 3-POLE, 10 AMPERES (MIL-PRF-6106 AND MIL-PRF-83536)
    MIL-PRF-83536-16 Revision D:2016 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 4PDT, LOW LEVEL TO 10 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COIL
    MIL-PRF-83536-7 Revision B:2013 Relays, Electromagnetic, Established Reliability, 4PDT, Low Level to 5 Amperes, Permanent Magnet Drive, Magnetic Latch, Hermetically Sealed, all Welded, DC Coils (No S/S Document)
    MIL-PRF-83536-6 Revision E:2016 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 4PDT, LOW LEVEL TO 5 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COILS
    MIL-PRF-83536-11 Revision C:2013 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 10 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, AC COILS
    MIL-PRF-83536-22 Revision D:2016 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 3PDT, LOW LEVEL TO 10 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COILS
    MIL-DTL-12883-40 Revision F:2003 SOCKETS, PLUG-IN ELECTRONIC COMPONENTS, FOR RELAYS, 4-POLE, 10 AMPERES (MIL-PRF-6106, MIL-PRF-83536, MIL-PRF-83726, AND MS27709)
    MIL-PRF-83726 Revision H:2017 Relays, Hybrid and Solid State, Time Delay, General Specification for
    MIL-PRF-83536-3 Revision C:2015 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 5 AMPERES, PERMANENT MAGNET DRIVE, MAGNETIC LATCH, HERMETICALLY SEALED, ALL WELDED, DC COILS
    MIL-PRF-83536-37 Base Document:2003 RELAY, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 1PDT, 25 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COILS
    MIL-PRF-83536-15 Revision A:2004 Relays, Electromagnetic, Established Reliability, 4PDT, Low Level to 10 Amperes, Permanent Magnet Drive, Hermetically Sealed, all Welded, DC Coil
    MIL-PRF-83536-10 Revision D:2015 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 10 AMPERES, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COILS
    MIL-PRF-83536-24 Revision B:2016 RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 3PDT, LOW LEVEL TO 10 AMPERES, PERMANENT MAGNETIC DRIVE, MAGNETIC LATCH, HERMETICALLY SEALED, ALL WELDED, TRANSIENT SUPPRESSED DC COILS
    MIL-PRF-83536-5 Revision D:2016 Relays, Electromagnetic, Established Reliability, 4PDT, Low Level to 5 Amperes, Permanent Magnet Drive, Hermetically Sealed, all Welded, DC Coils
    MIL-DTL-12883-56 Revision A:2003 Socket, Plug-in Electronic Components, for Relays, 1-Pole, 10 Amperes (MIL-PRF-83536/34 and /35)
    MIL-PRF-83536-12 Revision C:2013 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 10 Amperes, Magnetic Latch, Hermetically Sealed, all Welded, DC Coils
    MIL-PRF-83536-9 Revision E:2016 Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 10 Amperes, Permanent Magnet Drive, Hermetically Sealed, all Welded, DC Coils
    MIL-DTL-12883-47 Revision D:2003 SOCKET, PLUG-IN ELECTRONIC COMPONENTS, FOR RELAYS, 6-POLE, 10 AMPERES (MIL PRF 6106 AND MIL PRF 83536)
    MIL-DTL-12883-51 Revision B:2003 SOCKETS AND ACCESSORIES FOR PLUG-IN ELECTRONIC COMPONENTS, BRACKET AND SOCKET ASSEMBLY FOR RELAYS, 4-POLE, 10 AMPERES (MIL-PRF-6106, MIL-PRF-83536, AND MIL-PRF-83726)
    DSCC 84133 : E RELAYS, ELECTROMAGNETIC, PERMANENT MAGNET DRIVE, 2PDT, LOW LEVEL TO 5 AMPERES

    Standards Referencing This Book - (Show below) - (Hide below)

    MIL-STD-202-212 Base Document:2015 METHOD 212, ACCELERATION
    MIL-STD-202-211 Base Document:2015 METHOD 211, TERMINAL STRENGTH
    SAE AMS 2422 : 2014 PLATING, GOLD
    MIL-STD-202-302 Base Document:2015 METHOD 302, INSULATION RESISTANCE
    MIL-STD-883 Revision K:2016 TEST METHOD STANDARD - MICROCIRCUITS
    ANSI/NCSL Z540 3 : 2006(R2013) REQUIREMENTS FOR THE CALIBRATION OF MEASURING AND TEST EQUIPMENT
    MIL-STD-202-210 Base Document:2015 METHOD 210, RESISTANCE TO SOLDERING HEAT
    MIL-STD-1276 Revision H:2013 Leads for Electronic Component Parts
    MIL-STD-202-303 Base Document:2015 METHOD 303, DC RESISTANCE
    MIL-DTL-12883 Revision F:2003 Sockets and Accessories for Plug-in Electronic Components, General Specification for
    SAE AMS QQ N 290 : 2015 NICKEL PLATING (ELECTRODEPOSITED)
    MIL-STD-202-101 Base Document:2015 METHOD 101, SALT ATMOSPHERE (CORROSION)
    MIL-STD-750 Revision F:2011 TEST METHODS FOR SEMICONDUCTOR DEVICES
    MIL-STD-202-107 Base Document:2015 METHOD 107, THERMAL SHOCK
    MIL-HDBK-454 Revision B:2007 GENERAL GUIDELINES FOR ELECTRONIC EQUIPMENT
    MIL-STD-202-301 Base Document:2015 METHOD 301, DIELECTRIC WITHSTANDING VOLTAGE
    IEEE 315 : 1975 GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS)
    MIL-STD-202-215 Base Document:2015 METHOD 215, RESISTANCE TO SOLVENTS
    MIL-STD-790 Revision G:2011 ESTABLISHED RELIABILITY AND HIGH RELIABILITY QUALIFIED PRODUCTS LIST (QPL) SYSTEMS FOR ELECTRICAL, ELECTRONIC, AND FIBER OPTIC PARTS SPECIFICATIONS
    ISO 10012:2003 Measurement management systems — Requirements for measurement processes and measuring equipment
    MIL-STD-202-105 Base Document:2015 METHOD 105, BAROMETRIC PRESSURE (REDUCED)
    MIL-STD-202-208 Base Document:2015 METHOD 208, SOLDERABILITY
    MIL-STD-202 Revision H:2015 ELECTRONIC AND ELECTRICAL COMPONENT PARTS
    MIL-STD-1285 Revision D:2004 MARKING OF ELECTRICAL AND ELECTRONIC PARTS
    EIA 557 : 2006 STATISTICAL PROCESS CONTROL SYSTEMS
    MIL-STD-202-214 Base Document:2015 METHOD 214, RANDOM VIBRATION
    MIL-STD-690 Revision D:2005 Failure Rate (FR) Sampling Plans and Procedures
    MIL-STD-202-312 Base Document:2015 METHOD 312, LIFE, INTERMEDIATE CURRENT SWITCHING
    MIL-STD-202-204 Base Document:2015 METHOD 204, VIBRATION, HIGH FREQUENCY
    MIL-STD-202-112 Base Document:2015 METHOD 112, SEAL
    MIL-STD-202-213 Base Document:2015 METHOD 213, SHOCK (SPECIFIED PULSE)
    MIL-STD-202-307 Base Document:2015 METHOD 307, CONTACT RESISTANCE
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective