• ONORM EN 1366-5 : 2010

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 5: SERVICE DUCTS AND SHAFTS

    Available format(s): 

    Withdrawn date:  01-05-2021

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Osterreichisches Normungsinstitut/Austrian Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Test equipment
       4.1 General
       4.2 Furnace
       4.3 Loading equipment
       4.4 Gas extraction equipment (optional)
    5 Test conditions
       5.1 Furnace
       5.2 Loading
    6 Test specimen
       6.1 Size
            6.1.1 General
            6.1.2 Length
            6.1.3 Cross-section
       6.2 Number
       6.3 Design
            6.3.1 General
            6.3.2 Duct and shaft arrangement
    7 Installation of test specimen
       7.1 General
       7.2 Standard supporting construction
       7.3 Non-standard supporting constructions
    8 Conditioning
       8.1 General
       8.2 Hygroscopic sealing materials
    9 Application of instrumentation
       9.1 Thermocouples
            9.1.1 Furnace thermocouples (plate thermometers)
            9.1.2 Thermocouple locations
       9.2 Pressure
    10 Test procedure
       10.1 General
       10.2 Test measurements and observations
            10.2.1 General
            10.2.2 Integrity
            10.2.3 Insulation (temperature of the unexposed
                   face)
            10.2.4 Additional observations
       10.3 Termination of the test
    11 Performance criteria
       11.1 Integrity
       11.2 Insulation
    12 Test report
    13 Field of direct application of test results
       13.1 Walls or floors through which the ducts or shafts
            lead
       13.2 Sizes of ducts or shafts
            13.2.1 Fire exposure from outside
            13.2.2 Fire exposure from inside
       13.3 Admissible services
       13.4 Suspension devices for ducts
            13.4.1 Material and sizing
            13.4.2 Elongation
    Bibliography

    Abstract - (Show below) - (Hide below)

    Provides a method for determining the fire resistance of horizontal service ducts and vertical service shafts, which pass through walls or floors and enclose pipes and cables.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Osterreichisches Normungsinstitut/Austrian Standards
    Status Withdrawn
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    ONORM EN 1363-1 : 2012 FIRE RESISTANCE TESTS - PART 1: GENERAL REQUIREMENTS
    ISO 13943:2017 Fire safety — Vocabulary
    ONORM EN 1366-3 : 2009 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS
    ISO 898-1:2013 Mechanical properties of fasteners made of carbon steel and alloy steel — Part 1: Bolts, screws and studs with specified property classes — Coarse thread and fine pitch thread
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective