• SN EN 60071-1 : 2006 + A1 2010

    Current The latest, up-to-date edition.

    INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Swiss Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Definitions
    3.1 Insulation co-ordination
    3.2 External insulation
    3.3 Internal insulation
    3.4 Self-restoring insulation
    3.5 Non-self-restoring insulation
    3.6 Insulation configuration terminal
    3.7 Insulation configuration
    3.8 Normal voltage of a system
    3.9 Highest voltage of a system
    3.10 Highest voltage for equipment (Um)
    3.11 Isolated neutral system
    3.12 Solidly earthed neutral system
    3.13 Impedance earthed (neutral) system
    3.14 Resonant earthed (neutral) system
    3.15 Earth fault factor
    3.16 Overvoltage
    3.17 Classification of voltages and overvoltages
    3.18 Standard voltage shapes
    3.19 Representative overvoltages (Urp)
    3.20 Overvoltage limiting device
    3.21 Lightning (or switching) impulse protective level
    3.22 Performance criterion
    3.23 Withstand voltage
    3.24 Co-ordination withstand voltage (Ucw)
    3.25 Co-ordination factor (Kc)
    3.26 Standard reference atmospheric conditions
    3.27 Required withstand voltage (Urw)
    3.28 Atmospheric correction factor (Ka)
    3.29 Safety factor (Ks)
    3.30 Standard withstand voltage (Uw)
    3.31 Test conversion factor (Kt)
    3.32 Rated insulation level
    3.33 Standard insulation level
    3.34 Standard withstand voltage tests
    4 Procedure for insulation co-ordination
    4.1 General outline of the procedure
    4.2 Determination of the representative overvoltages (Urp)
    4.3 Determination of the co-ordination withstand
         voltages (Ucw)
    4.4 Determination of the required withstand
         voltages (Urw)
    4.5 Selection of the rated insulation level
    4.6 List of standard short-duration power frequency
         withstand voltages
    4.7 List of standard impulse withstand voltages
    4.8 Ranges for highest voltage for equipment
    4.9 Selection of the standard insulation levels
    5 Requirements for standard withstand voltage tests
    5.1 General requirements
    5.2 Standard short-duration power-frequency
         withstand voltage tests
    5.3 Standard impulse withstand voltage tests
    5.4 Alternative test situation
    5.5 Phase-to-phase and longitudinal insulation
         standard withstand voltage tests for
         equipment in range I
    5.6 Phase-to-phase and longitudinal insulation
         standard withstand voltage tests for
         equipment in range II
    Figure
    Tables
    Annex A
    Annex ZA (normative) Normative references to
    international publications with their
    corresponding European publications


         
         

    Abstract - (Show below) - (Hide below)

    Specifies the procedure for the selection of the standard withstand voltages for the phase-to-earth, phase-to-phase and longitudinal insulation of the equipment and the installations of these systems. Applies to three-phase a.c. systems that have a highest voltage for equipment above 1 kV. Recommends that the selected withstand voltages should be associated with the highest voltage for equipment.

    General Product Information - (Show below) - (Hide below)

    Development Note 2006 Edition Re-Issued in May 2010 & incorporates AMD 1 2010. (06/2011)
    Document Type Standard
    Publisher Swiss Standards
    Status Current