• SN EN 60076-3 : 2001

    Current The latest, up-to-date edition.

    POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Swiss Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    Clause
    1 Scope
    2 Normative references
    3 Definitions
    4 General
    5 Highest voltage for equipment and insulation level
    6 Rules for some particular transformers
    7 Insulation requirements and dielectric tests - Basic
       rules
       7.1 General
       7.2 Insulation requirements
       7.3 Dielectric tests
       7.4 Insulation requirements and tests for the neutral
           terminal of a winding
    8 Tests on a transformers having a tapped winding
    9 Repeated dielectric tests
    10 Insulation of auxiliary wiring
    11 Separate source AC withstand voltage test
    12 Induced AC voltage tests (ACSD, ACLD)
       12.1 General
       12.2 Short-duration induced AC withstand voltage test
            (ACSD) for transformers with uniformity insulated
            high-voltage windings
       12.3 Short-duration AC withstand voltage test (ACSD) for
            transformers with non-uniformity insulated
            high-voltage windings
       12.4 Long-duration induced AC voltage test (ACSD) with
            non-uniformity and/or uniformity insulated
            high-voltage windings, according to table 1
    13 Lightning impulse (LI) test
       13.1 General
       13.2 Test sequence
       13.3 Test connections
       13.4 Records of test
       13.5 Test criteria
    14 Test with lightning impulse chopped on the tail (LIC)
       14.1 General
       14.2 Chopping gap and characteristics of the chopping
       14.3 Test sequence and test criteria
    15 Switching impulse test (SI)
       15.1 General
       15.2 Test sequence and records
       15.3 Test connections
       15.4 Test criteria
    16 External clearances in air
       16.1 General
       16.2 Bushing clearance requirements as determined by
            transformer insulation withstand voltages
    Annex A (Informative) Application guide for partial
            discharge measurements during induced a.c.
            withstand voltage test on transformers according
            to 12.2, 12.3 and 12.4
    Annex B (informative) Overvoltage transferred from the
            high-voltage winding to a low-voltage winding
    Annex C (informative) Information on transformer
            insulation and dielectric tests to be supplied
            with an enquiry an order
    Annex D (normative) ACSD
    Annex ZA (normative) Normative references to international
             publications with their corresponding European
             publications
    Annex ZB (normative) Special national conditions

    Abstract - (Show below) - (Hide below)

    Applies to single-phase and three-phase oil-immersed power transformers with the exception of certain small and special transformers.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes SN HD 398.3 (05/2002)
    Document Type Standard
    Publisher Swiss Standards
    Status Current