    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    Section 1. General
    1.1 Scope and object
    1.2 Normative references
    1.3 Definitions
    Section 2. Insulators
    2.1 Insulator designs and insulating materials
    2.2 Values which characterize a post insulator
    2.3 Identification of insulators
    Section 3. Classification of the tests, sampling
               rules and procedures
    3.1 Classification of the tests
    3.2 Quality assurance
    3.3 General requirements for type tests
    3.4 General requirements for sample tests
    Section 4. Test procedures for electrical tests
    4.1 General requirements for high-voltage tests
    4.2 Standard atmospheric conditions and correction
         factors for electrical tests
    4.3 Artificial rain parameters for wet tests
    4.4 Mounting arrangements for electrical tests
    4.5 Dry lightning-impulse withstand voltage test-Type test
    4.6 Dry or wet switching-impulse withstand voltage tests
         - Type test
    4.7 Dry power-frequency withstand voltage test - Type test
         (applicable only to post insulators for indoor use)
    4.8 Wet power-frequency withstand voltage test - Type test
         (applicable only to post insulators for outdoor use)
    4.9 Puncture test - Sample test
    4.10 Routine electrical test
    Section 5. Test procedures for mechanical and other tests
    5.1 Verification of the dimensions - Type and sample test
    5.2 Mechanical failing load test - Type and sample test
    5.3 Test for deflection under load - Special type test
    5.4 Temperature cycle test - Sample test
    5.5 Routine thermal shock test (applicable only to
         toughened glass insulating parts)
    5.6 Porosity test - Sample test (applicable only to
         ceramic post insulators)
    5.7 Galvanizing test - Sample test
    5.8 Routine visual inspection
    5.9 Routine mechanical test
    Section 6. Tests applicable to post insulators
    6.1 Type tests
    6.2 Sample tests
    6.3 Routine tests
    6.4 Summary of tests on post insulators
    Annex A (informative) Methods of testing for tolerances
            of parallelism, eccentricity, angular deviation,
            camber and shed angle of post insulators
    Annex B (informative) Methods of routine testing of
            unassembled insulator units
    Annex C (informative) Bibliography
    Annex ZA (normative) Other international publications
             quoted in this standard with the references of
             the relevant European publications

    Abstract - (Show below) - (Hide below)

    Applies to post insulators and post insulator units of ceramic material or glass, for indoor and outdoor use in electrical installations or equipment, operating on alternating current with a nominal voltage greater than 1000 V and a frequency not more than 100 Hz.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Swiss Standards
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective