• SN EN 60664-4 : 2006

    Current The latest, up-to-date edition.

    INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 4: CONSIDERATIONS OF HIGH-FREQUENCY VOLTAGE STRESS

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Swiss Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 Scope and object
    2 Normative references
    3 Terms and definitions
    4 Clearances
      4.1 General conditions
      4.2 Basic information
      4.3 Homogeneous and approximately homogeneous fields
          4.3.1 Conditions for approximately homogeneous field
          4.3.2 Experimental data of breakdown characteristics
          4.3.3 Dimensioning of clearances for homogeneous and
                approximately homogeneous field conditions
      4.4 Inhomogeneous fields
          4.4.1 Conditions for inhomogeneous field
          4.4.2 Experimental data of partial discharge and
                breakdown characteristics
          4.4.3 Dimensioning of clearances for inhomogeneous
                field conditions
    5 Creepage distances
      5.1 Experimental data
      5.2 Dimensioning of creepage distances
    6 Solid insulation
      6.1 General consideration
      6.2 Influencing factors
      6.3 Dimensioning of solid insulation
    7 High-frequency testing
      7.1 Basic requirements
      7.2 Test voltage source
      7.3 Conditioning
      7.4 High-frequency breakdown test
          7.4.1 Test method
          7.4.2 Test result
      7.5 High-frequency partial discharge test
          7.5.1 General considerations
          7.5.2 Test method
          7.5.3 Test equipment
          7.5.4 Test circuit
          7.5.5 Required bandwidth of the test circuit
          7.5.6 Dimensioning of the test circuit
      7.6 Examples of test results
    8 Non sinusoidal voltages
      8.1 General considerations
      8.2 Periodic impulse voltage
      8.3 Harmonic analysis
      8.4 Dimensioning procedure and testing
    Annex A (informative) Insulation characteristics of
                          clearances at high-frequency
                          voltages
      A.1 Basic information about the breakdown of clearances
      A.2 Experimental data
          A.2.1 Homogeneous and approximately homogeneous field
                distribution
          A.2.2 Inhomogeneous field distribution
    Annex B (informative) Insulation characteristics of creepage
                          distances at high-frequency voltages
      B.1 Withstand characteristics of creepage distances
      B.2 Experimental conditions
      B.3 Experimental data
    Annex C (informative) Insulation characteristics of solid
                          insulation at high-frequency voltages
      C.1 Degradation mechanism of solid insulation
      C.2 Experimental results
    Annex D (normative) Testing of insulation at high-frequency
                        voltages
      D.1 Test voltage source
      D.2 High-frequency partial discharge test
          D.2.1 Test equipment
          D.2.2 Test circuit
      D.3 Examples of test results
    Annex E (informative) Insulation stressed with non-sinusoidal
                          high-frequency voltages
      E.1 Objective
      E.2 Harmonic analysis
    Annex F (informative) Dimensioning diagrams
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes basic, supplementary and reinforced insulation subjected to high-frequency voltage stress within low-voltage equipment.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Swiss Standards
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective