• SN EN 60865-1 : 1993

    Current The latest, up-to-date edition.

    SHORT-CIRCUIT CURRENTS; CALCULATION OF EFFECTS; PART 1: DEFINITIONS AND CALCULATION METHODS

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Swiss Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    National foreword
    Section 1. General
    1.1 Scope and object
    1.2 Normative references
    1.3 Equations, symbols and units
    1.4 Definitions
    Section 2. The electromagnetic effect on rigid conductors
    and flexible conductors
    2.1 General
    2.2 Rigid conductor arrangements
    2.3 Flexible conductor arrangements
    2.4 Structure loads due to electromagnetic effects
    Section 3. The thermal effect on bare conductors and
    electrical equipment
    3.1 General
    3.2 Calculation of temperature rise
    Annexes
    A. (normative) Equations for calculation of diagrams
    B. (informative) Iteration-procedure for calculation
        of factor eta for the tensile force Fpi in the
        case of non-clashing bundled conductors according
        to IEC 865, 2.3.3.3 equation (62)
    Tables
    1. Effective distance as between sub-conductors in
         metres, for rectangular cross-section dimensions
    2. Maximum possible values of Vsigma Vr, Vsigma s Vrs,
         VF Vr
    3. Factors alpha, beta, and gamma for different
         busbar support arrangements
    4. Factor q
    5. Section moduli Z of main conductors with two or
         more stiffening elements between two adjacent
         supports
    Figures
    1. Factor kls for calculating the effective conductor
         distance
    2. Loading direction and bending axis for multiple
         conductor arrangements
    3. Factor c for the influence of connecting pieces in
         equation (17)
    4. Factors VF, Vsigma and Vsigma s to be used with
         the three-phase and line-to-line short circuits
    5. Factors Vr and Vrs to be used with three-phase
         automatic reclosing
    6. Maximum swing out angle sigma m for a given maximum
         short-circuit duration Tk1
    7. Factor psi for tensile force in flexible conductors
    8. v2 as a function of v1
    9. v3 . sin 180 deg/n as a function of as/ds
    10. xi as a function of j and epsilon st
    11a. eta as a function of j and epsilon st
    11b. eta as a function of j and epsilon st
    11c. eta as a function of j and epsilon st
    12a. Factor m, heat dissipation due to d.c. component in
         three-phase systems and single-phase systems
    12b. Factor n, heat dissipation due to a.c. component in
         three-phase systems and approximately for single-
         phase systems
    13. Relation between rated short-time withstand current
         density (Tkr = 1 s) and conductor temperature

    Abstract - (Show below) - (Hide below)

    Applies to the mechanical and thermal effects of short-circuit currents. Includes the following sections: the electromagnetic effect on rigid conductors and flexible conductors; the thermal effect on bare conductors and electrical equipment. Also includes detailed tables and annexes.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Swiss Standards
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective