• SN EN 61000-2-4 : 2002

    Current The latest, up-to-date edition.

    ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Swiss Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 Scope
    2 Normative references
    3 Definitions
       3.1 General definitions
       3.2 Phenomena-related definitions
    4 Electromagnetic environment classes
    5 Compatibility levels
       5.1 General comment
       5.2 Voltage deviations
       5.3 Voltage dips and short-time interruptions
       5.4 Voltage unbalance
       5.5 Temporary power-frequency variation
       5.6 Harmonics
       5.7 Interharmonics
       5.8 Voltage components at higher frequencies (above 50th
            harmonic)
       5.9 Transient overvoltages
       5.10 DC component
    6 Compatibility levels
    Annex A (informative) Explanations and examples for
            interharmonics
       A.1 Resolution of non-sinusoidal voltages and currents
       A.2 Time varying phenomena
       A.3 Definition of additional terms
    Annex B (informative) Examples of expected disturbance levels
            in typical industrial networks
       B.1 Voltage disturbance levels in industrial networks due
            to large converters
       B.2 Voltage disturbance levels in industrial networks at
            high load
       B.3 Voltages dips and short interruption
       B.4 Transient overvoltages
    Annex C (informative) Interharmonic and voltages at higher
            frequencies
       C.1 Sources of interharmonics
       C.2 Mitigation methods
       C.3 Voltages at higher frequencies
    Annex ZA (normative) Normative references to international
             publications with their corresponding European
             publications

    Abstract - (Show below) - (Hide below)

    Deals with conducted disturbances in the frequency range from 0 kHz to 9 kHz. Also provides numerical compatibility levels for industrial and non-public power distribution systems at nominal voltages up to 35 kV and a nominal frequency of 50 Hz or 60 Hz.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Swiss Standards
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective