    ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1 KV A.C. AND 1.5 KV D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS

    Available format(s): 

    Withdrawn date:  01-02-2012

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Swiss Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Definitions
    4 Requirements
    5 Marking and operating instructions
          5.1 Marking
          5.2 Operating instructions
    6 Tests
          6.1 Type test
                 6.1.1 Response sensitivity of the insulation
                          fault location system
                 6.1.2 Test current (IT)
                 6.1.3 Alarm indicator
                 6.1.4 Clearance and creepage distances
                 6.1.5 Dielectric test
                 6.1.6 Electromagnetic compatibility (EMC)
                 6.1.7 Additional requirements
                 6.1.8 Marking and operating instructions
          6.2 Routine tests
                 6.2.1 Response sensitivity
                 6.2.2 Test current (IT)
                 6.2.3 Alarm indicator
                 6.2.4 Dielectric test
                 6.2.5 Marking and operating instructions
                 6.2.6 Record of routine tests
          6.3 Example of a test matrix for type and routine
                 tests
    Figure 1 - Example of the components included in an insulation
               fault location system
    Table 1 - Requirements for insulation fault location systems
    Annex ZA (normative) Normative references to international
                         publications with their corresponding
                         European publications

    Abstract - (Show below) - (Hide below)

    TO BE USED IN CONJUNCTION WITH IEC 61557-1. Gives the requirements for insulation fault location systems which localize insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically connected d.c. circuits having nominal voltages up to 1000 V a.c., as well as unearthed IT d.c. systems with voltages up to 1 500 V d.c., independent of the measuring principle.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Swiss Standards
    Status Withdrawn
    Superseded By
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective