• SN EN 61954 : 1999 AMD 1 2003

    Current The latest, up-to-date edition.

    POWER ELECTRONICS FOR ELECTRICAL TRANSMISSION AND DISTRIBUTION SYSTEMS - TESTING OF THYRISTOR VALVES FOR STATIC VAR COMPENSATORS

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Swiss Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Definitions
    4 General requirements for type and optional tests
          4.1 Summary of tests
          4.2 Objectives of tests
                 4.2.1 Dielectric tests
                 4.2.2 Operational tests
                 4.2.3 Electromagnetic interference tests
                 4.2.4 Production tests
                 4.2.5 Optional tests
          4.3 Guidelines for the performance of type and
                 optional tests
          4.4 Test conditions
                 4.4.1 General
                 4.4.2 Valve temperature at testing
                 4.4.3 Redundant thristor levels
          4.5 Permissible component failures during type
                 testing
          4.6 Documentation of test results
                 4.6.1 Test reports to be issued
                 4.6.2 Contents of a type test report
    5 Type tests on TCR and TSR valves
          5.1 Dielectric tests between valve terminals and
                 earth
                 5.1.1 AC test
                 5.1.2 Lightning impulse test
          5.2 Dielectric tests between valves (MVU only)
                 5.2.1 AC test
                 5.2.2 Lightning impulse test
          5.3 Dielectric tests between valve terminals
                 5.3.1 AC test
                 5.3.2 Switching impulse test
          5.4 Operational tests
                 5.4.1 Periodic firing and extinction test
                 5.4.2 Minimum a.c. voltage test
                 5.4.3 Temperature rise test
    6 Type tests on TSC valves
          6.1 Dielectric tests between valve terminals and
                 earth
                 6.1.1 AC-DC test
                 6.1.2 Lightning impulse test
          6.2 Dielectric tests between valves (for MVU only)
                 6.2.1 AC-DC test
                 6.2.2 Lightning impulse test
          6.3 Dielectric tests between valve terminals
                 6.3.1 AC-DC test
                 6.3.2 Switching impulse test
          6.4 Operational tests
                 6.4.1 Overcurrent tests
                 6.4.2 Minimum a.c. voltage test
                 6.4.3 Temperature rise test
    7 Electromagnetic interference tests
          7.1 Objectives
          7.2 Test procedures
                 7.2.1 Switching impulse test
                 7.2.2 Non-periodic firing test
    8 Production tests
          8.1 Visual inspection
          8.2 Connection check
          8.3 Voltage-dividing/damping circuit check
          8.4 Voltage withstand check
          8.5 Check of auxiliaries
          8.6 Firing check
          8.7 Cooling system pressure test
    9 Optional tests on TCR and TSR valves
          9.1 Overcurrent test
                 9.1.1 Overcurrent with subsequent blocking
                 9.1.2 Overcurrent without blocking
          9.2 Positive voltage transient during recovery test
                 9.2.1 Objectives
                 9.2.2 Test values and waveshapes
                 9.2.3 Test procedures
          9.3 Non-periodic firing test
                 9.3.1 Objectives
                 9.3.2 Test values and waveshapes
                 9.3.3 Test procedures
    10 Optional tests on TSC valves
          10.1 Positive voltage transient during recovery test
                 10.1.1 Test objective
                 10.1.2 Test values and waveshapes
                 10.1.3 Test procedures
          10.2 Non-periodic firing test
                 10.2.1 Objectives
                 10.2.2 Test values and waveshapes
                 10.2.3 Test procedures
    Figure 1 - TSC branch
    Figure 2 - One-loop overcurrent
    Figure 3 - Two-loop overcurrent
    Table 1 - List of type tests and operational tests
    Annex ZA (normative) Normative references to international
                         publications with their corresponding
                         European publications

    Abstract - (Show below) - (Hide below)

    Describes type, production and optional tests on thyristor valves used in thyristor controlled reactors (TCR), thyristor switched reactors (TSR) and thyristor switched capacitors (TSC) forming part of static VAR compensators (SVC) for power system applications.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Swiss Standards
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective