• SN EN 62040-1-1 : 2003

    Current The latest, up-to-date edition.

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Swiss Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope and specific applications
       1.1 Scope
       1.2 Specific applications
    2 Normative references
    3 Definitions
       3.1 General
       3.2 UPS electrical ratings
       3.3 Load types
       3.4 Connection to the supply
       3.5 Circuits and circuit characteristics
       3.6 Insulation
       3.7 Equipment mobility
       3.8 Insulation classes of UPS
       3.9 Enclosures
       3.10 Accessibility
       3.11 Components
       3.12 Power distribution
       3.13 Flammability
       3.14 Miscellaneous
       3.15 Telecommunication networks
    4 General conditions for tests
       4.1 Operating parameters for tests
       4.2 Loads for tests
       4.3 Components
       4.4 Power interfaces
       4.5 Marking and instructions
            4.5.1 General
            4.5.2 Power rating
            4.5.3 Safety instructions
            4.5.4 Main voltage adjustment
            4.5.5 Power outlets
            4.5.6 Fuses
            4.5.7 Wiring terminals
            4.5.8 Battery terminals
            4.5.9 Controls and indicators
            4.5.10 Isolation of multiple power sources
            4.5.11 IT power systems
            4.5.12 Protection in building installation
            4.5.13 High leakage current
            4.5.14 Thermostats and other regulating devices
            4.5.15 Language
            4.5.16 Durability of markings
            4.5.17 Removable parts
            4.5.18 Replaceable batteries
            4.5.19 Operator access with a tool
            4.5.20 Battery
            4.5.21 Installation instructions
    5 Fundamental design requirements
       5.1 Protection against electric shock and energy
            hazards
            5.1.1 Operator access
            5.1.2 Access to ELV wiring
            5.1.3 Discharge of capacitors in the primary
                   circuit
            5.1.4 Backfeed protection
            5.1.5 Emergency switching device
       5.2 Insulation
       5.3 Limited current circuits
       5.4 Provisions for protective earthing
            5.4.1 Protective earthing
            5.4.2 Bonding
       5.5 AC and d.c. power isolation
            5.5.1 Disconnect devices
            5.5.2 Three-phase equipment
            5.5.3 Switch as a disconnect
            5.5.4 Multiple power sources
            5.5.5 Ungrounded conductors
       5.6 Overcurrent and earth fault protection
            5.6.1 Basic requirements
            5.6.2 Battery circuit protection
            5.6.3 Location of protective device
            5.6.4 Rating of protective device
       5.7 Protection of personnel - Safety interlocks
            5.7.1 Operator protection
            5.7.2 Service person protection
       5.8 Clearances, creepage distances and distances
            through insulation
       5.9 External signalling circuits
       5.10 Limited power source
    6 Wiring, connections and supply
       6.1 General
       6.2 Connection to power
            6.2.1 Means of connection
       6.3 Wiring terminals for external power conductors
    7 Physical requirements
       7.1 Enclosure
       7.2 Stability
       7.3 Mechanical strength
       7.4 Construction details
            7.4.1 Openings
            7.4.2 Gas concentration
            7.4.3 Equipment movement
       7.5 Resistance to fire
       7.6 Battery location
            7.6.1 Accessibility and maintainability
            7.6.2 Vibration
            7.6.3 Distance
            7.6.4 Insulation
            7.6.5 Wiring
            7.6.6 Electrolyte spillage
            7.6.7 Ventilation
            7.6.8 Charging voltages
       7.7 Temperature rise
    8 Electrical requirements and simulated abnormal
       conditions
       8.1 General
            8.1.1 Earth leakage current
            8.1.2 Pluggable equipment type B UPS
       8.2 Electric strength
       8.3 Abnormal operating and fault conditions
            8.3.1 Simulation of faults
            8.3.2 Conditions for tests
    9 Connection to telecommunication networks
    Annexes
    Annex H (informative) Guidance on protection against
            ingress of water and foreign objects
    Annex L (normative) Backfeed protection test
    Annex M (normative) Examples of reference load conditions
    Annex N (normative) Ventilation of battery compartments
    Annex X (informative) Guidance for disconnection of
            batteries during shipment
    Annex ZA (normative) Normative references to international
             publications with their corresponding European
             Publication
    Figures
    Tables

    Abstract - (Show below) - (Hide below)

    Covers electronic uninterruptible power systems (UPS) with an electrical energy storage device in the d.c. link.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Swiss Standards
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective