• SN EN 62271-105 : 2003

    Current The latest, up-to-date edition.

    HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Swiss Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 General
       1.1 Scope
       1.2 Normative references
    2 Normal and special service conditions
    3 Definitions
       3.1 General terms
       3.2 Assemblies
       3.3 Parts of assemblies
       3.4 Switching devices
       3.5 Parts of switching devices
       3.6 Operation
       3.7 Characteristic quantities
       3.8 Fuses
    4 Ratings
       4.1 Rated voltage (U[r])
       4.2 Rated insulation level
       4.3 Rated frequency (f[r])
       4.4 Rated normal current and temperature-rise
       4.5 Rated short-time withstand current (I[k])
       4.6 Rated peak withstand current (I[p])
       4.7 Rated duration of short circuit ([k])
       4.8 Rated supply voltage of closing and opening devices
            and auxiliary circuits (U[a] )
       4.9 Rated supply frequency of closing and opening devices
            and of auxiliary circuits
       4.10 Rated pressure of compressed gas supply for operation
    5 Design and construction
       5.1 Requirements for liquids in switch-fuse combinations
       5.2 Requirements for gases in switch-fuse combinations
       5.3 Earthing of switch-fuse combinations
       5.4 Auxiliary equipment
       5.5 Dependent power operation
       5.6 Stored energy operation
       5.7 Independent manual operation
       5.8 Operation of releases
       5.9 Low- and high pressure interlocking devices
       5.10 Nameplates
       5.11 Interlocking devices
       5.12 Position indication
       5.13 Degrees of protection by enclosures
       5.14 Creepage distances
       5.15 Gas and vacuum tightness
       5.16 Liquid tightness
       5.17 Flammability
       5.18 Electromagnetic compatibility (EMC)
    6 Type tests
       6.1 General
       6.2 Dielectric tests
       6.3 Radio interference voltage (RIV) tests
       6.4 Measurement of the resistance of the main circuit
       6.5 Temperature-rise tests
       6.6 Short-time withstand current and peak withstand
            current tests
       6.7 Verification of the protection
       6.8 Tightness tests
       6.9 Electromagnetic compatibility tests (EMC)
    7 Routine tests
    8 Guide for the selection of switch-fuse combinations for
       transformer protection
    9 Information to be given with enquiries, tenders and orders
    10 Rules for transport, storage, installation, operation and
       maintenance
    11 Safety
    Annex A (informative) Example of the coordination of fuses,
                          switch and transformer
    Annex B (normative) Procedure for determining transfer current
    Annex ZA (normative) Normative references to international
                         publications with their corresponding
                         European publications

    Abstract - (Show below) - (Hide below)

    Applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses designed so as to be capable of breaking, at the rated recovery voltage, any current up to and including the rated short-circuit breaking current and making, at the rated voltage, circuits to which the rated short-circuit breaking current applies.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Swiss Standards
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications