• TR 102 273-7 : 1.2.1

    Current The latest, up-to-date edition.

    ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 7: ARTIFICIAL HUMAN BEINGS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date: 

    Publisher:  European Telecommunications Standards Institute

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Intellectual Property Rights
    Foreword
    1 Scope
    2 References
    3 Definitions, symbols and abbreviations
      3.1 Definitions
      3.2 Symbols
      3.3 Abbreviations
    4 Introduction
      4.1 Artificial Human Beings
          4.1.1 Saltwater column
          4.1.2 Salty man
          4.1.3 "Salty-lite"
          4.1.4 Other salties
      4.2 Simulation of the human form
      4.3 Test conditions
    5 Uncertainty contributions specific to Salty man/Salty-lite
      5.1 Comparison between average humans and Salties
      5.2 Uncertainties associated with the use of Salty man and
          Salty-lite
      5.3 Measurement considerations for Salty man and Salty-lite
          5.3.1 Frequency ranges
          5.3.2 Uncertainties of use
          5.3.3 Conclusion
    6 Verification procedure for the Salty man and Salty-lite
      6.1 Definition
      6.2 Overview of the verification procedure
          6.2.1 Apparatus required
          6.2.2 Site preparation
          6.2.3 Measurement configuration
          6.2.4 What to record
      6.3 Verification procedure
      6.4 Processing the results of the verification procedure
          6.4.1 Report format
      6.5 Calculation of measurement uncertainty
          6.5.1 Introduction
          6.5.2 Discussion of uncertainty contributions
          6.5.3 Uncertainty contribution, actual measurement
    7 Test methods
      7.1 Introduction
          7.1.1 Site preparation
          7.1.2 Preparation of the EUT
          7.1.3 Standard antennas
          7.1.4 Mutual coupling and mismatch loss correction
                factors
          7.1.5 Power supplies to the EUT
          7.1.6 Restrictions
      7.2 Transmitter tests
          7.2.1 Frequency error
          7.2.2 Effective radiated power
          7.2.3 Spurious emissions
          7.2.4 Adjacent channel power
      7.3 Receiver tests
          7.3.1 Sensitivity tests in an Anechoic Chamber
                 (30 MHz to 1 000 MHz)
                 7.3.1.1 Apparatus required
                 7.3.1.2 Method of measurement
                 7.3.1.3 Procedure for completing the results
                         sheets
                 7.3.1.4 Log book entries
                 7.3.1.5 Statement of results
          7.3.2 Measurement uncertainty for Receiver Sensitivity
                 (Anechoic Chamber)
                 7.3.2.1 Uncertainty contributions: Stage 1:
                         Determination of transform factor
                 7.3.2.2 Uncertainty contributions: Stage 2:
                         EUT measurement
                 7.3.2.3 Expanded uncertainty of the receiver
                         sensitivity measurement
          7.3.3 Sensitivity tests in an Anechoic Chamber with a
                 Ground Plane (30 MHz to 1 000 MHz)
                 7.3.3.1 Apparatus required
                 7.3.3.2 Method of measurement
                 7.3.3.3 Procedure for completion of the results
                         sheets
                 7.3.3.4 Log book entries
                 7.3.3.5 Statement of results
          7.3.4 Measurement uncertainty for Receiver Sensitivity
                 7.3.4.1 Uncertainty contributions: Stage 1:
                         Determination of transform factor
                 7.3.4.2 Uncertainty contributions: Stage 2:
                         EUT measurement
                 7.3.4.3 Expanded uncertainty of the receiver
                         sensitivity measurement
          7.3.5 Sensitivity tests (Open Area Test Site)
                 (30 to 1 000 MHz)
                 7.3.5.1 Apparatus required
                 7.3.5.2 Method of measurement
                 7.3.5.3 Procedure for completion of the results
                         sheets
                 7.3.5.4 Log book entries
                 7.3.5.5 Statement of results
          7.3.6 Measurement uncertainty for Receiver Sensitivity
                 7.3.6.1 Uncertainty contributions: Stage 1:
                         Determination of transform factor
                 7.3.6.2 Uncertainty contributions: Stage 2:
                         EUT measurement
                 7.3.6.3 Expanded uncertainty of the receiver
                         sensitivity measurement
          7.3.7 Co-channel rejection
          7.3.8 Adjacent channel selectivity
          7.3.9 Intermodulation immunity
          7.3.10 Blocking immunity or desensitization
          7.3.11 Spurious response rejection
    Annex A: Bibliography
    History

    Abstract - (Show below) - (Hide below)

    Gives background to the subject of measurement uncertainty and proposes extensions and improvements relevant to radiated measurements.

    General Product Information - (Show below) - (Hide below)

    Committee ERM RP02
    Document Type Standard
    Publisher European Telecommunications Standards Institute
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    TS 103 051 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); EXPANDED MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS
    TR 102 215 : 1.3.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); RECOMMENDED APPROACH, AND POSSIBLE LIMITS FOR MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS ABOVE 1 GHZ
    EG 202 290 : 1.1.1 FINAL DRAFT ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); MEASUREMENT UNCERTAINTIES AND TEST METHODOLOGIES FROM 1 GHZ TO 40 GHZ

    Standards Referencing This Book - (Show below) - (Hide below)

    TR 102 273-1-2 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 2: EXAMPLES AND ANNEXES
    TR 100 028-1 : 1.4.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS PART 1
    TR 102 273-1-1 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 1: INTRODUCTION
    IEC 60489-6:1999 Radio equipment used in mobile services - Methods of measurement - Part 6: Data equipment
    ANSI C63.5 : 2006 ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ)
    TR 100 027 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); METHODS OF MEASUREMENT FOR PRIVATE MOBILE RADIO EQUIPMENT
    TR 100 028-2 : 1.4.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS PART 2
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective