• UNE-EN 50399:2012

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results

    Available format(s):  Hardcopy, PDF

    Superseded date:  01-03-2023

    Language(s): 

    Published date:  21-03-2012

    Publisher:  Asociacion Espanola de Normalizacion

    Add To Cart

    General Product Information - (Show below) - (Hide below)

    Committee CTN 211/SC 20
    Document Type Standard
    Publisher Asociacion Espanola de Normalizacion
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN ISO 5167-2:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates (ISO 5167-2:2003)
    ISO 9705:1993 Fire tests Full-scale room test for surface products
    89/106/EEC : 1988 COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS
    ISO 13943:2017 Fire safety — Vocabulary
    ISO 5167-4:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 4: Venturi tubes
    EN 13823:2010+A1:2014 REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM
    EN ISO 5167-4:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 4: Venturi tubes (ISO 5167-4:2003)
    ISO 5167-2:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates
    EN 60332-3-10:2009 Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
    EN 14390:2007 Fire test - Large-scale room reference test for surface products
    EN 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
    EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
    ISO 3966:2008 Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes
    IEC 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
    IEC 60332-3-10:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective