• UNE-EN 60079-2:2015

    Current The latest, up-to-date edition.

    Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"

    Available format(s):  Hardcopy, PDF

    Language(s):  Spanish, Castilian, English

    Published date:  30-09-2015

    Publisher:  Asociacion Espanola de Normalizacion

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Protection types
    5 Constructional requirements for pressurized enclosures
       5.1 Enclosure
       5.2 Materials
       5.3 Doors and covers
       5.4 Mechanical strength
       5.5 Apertures, partitions, compartments and internal
           components
       5.6 Insulating materials
       5.7 Sealing
       5.8 Spark and particle barriers
    6 Temperature limits
       6.1 General
       6.2 For type px or type py
       6.3 For type pz
    7 Safety provisions and safety devices (except for
       static pressurization)
    8 Safety provisions and safety devices for static
       pressurization
    9 Supply of protective gas
       9.1 Type of gas
       9.2 Temperature
    10 Pressurized apparatus with an internal source of
       release
    11 Release conditions
       11.1 No release
       11.2 Limited release of a gas or vapour
       11.3 Limited release of a liquid
    12 Design requirements for the containment system
       12.1 General design requirements
       12.2 Infallible containment system
       12.3 Containment system with a limited release
    13 Protective gas and pressurizing techniques
       13.1 General
       13.2 Pressurization with leakage compensation
       13.3 Pressurization with dilution
    14 Ignition-capable apparatus
    15 Internal hot surfaces
    16 Type verification and tests
       16.1 Maximum overpressure test
       16.2 Leakage test
       16.3 Purging test for pressurized enclosures with no
            internal source of release (pressurization
            technique may be leakage compensation or
            continuous flow) and filling procedure test for
            static pressurization
       16.4 Purging and dilution tests for a pressurized
            enclosure with an internal source of release
       16.5 Verification of minimum overpressure
       16.6 Tests for an infallible containment system
       16.7 Overpressure test for a containment system with a
            limited release
       16.8 Verifying ability of the pressurized enclosure to
            limit internal pressure
    17 Routine tests
       17.1 Functional test
       17.2 Leakage test
       17.3 Tests for an infallible containment system
       17.4 Test for a containment system with a limited release
    18 Marking
    Annex A (normative) Purging and dilution tests
    Annex B (informative) Examples of functional sequence diagram
    Annex C (informative) Examples of the changes in pressure in
                          ducts and enclosures
    Annex D (informative) Information to be provided to the user
    Annex E (normative) Classification of the type of release
                          within enclosures
    Annex F (informative) Examples for the use of the dilution area
                          concept
    Annex G (normative) Infallibility test for containment system
    Annex ZA (normative) Normative references to international
                          publications with their corresponding
                          European publications
    Bibliography
    Figures
    Tables

    Abstract - (Show below) - (Hide below)

    Contains the specific requirements for the construction and testing of electrical apparatus with pressurized enclosures, of protection type 'p', intended for use in explosive gas atmospheres.

    General Product Information - (Show below) - (Hide below)

    Committee CTN 202/SC 31
    Development Note Supersedes UNE EN 50016. (06/2007) Supersedes UNE 20319. (04/2010) Supersedes UNE EN 61241-4. (09/2017)
    Document Type Standard
    Publisher Asociacion Espanola de Normalizacion
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNE 60631-1:2014 Compressed natural gas filling stations. Part 1: Stations with supply capacity above 20 m3/h.

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
    IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
    EN 60079-26:2015 Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
    EN 60079-1:2014 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
    EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
    EN 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
    IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
    IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
    IEC 60079-20-1:2010 Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
    EN 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
    EN 60079-28:2015 Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation
    IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
    IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
    EN 60112 : 2003 AMD 1 2009 METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS
    EN 60079-11:2012 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
    IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
    EN 60079-20-1:2010 Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
    EN 60079-5:2015 Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    EN 60079-13:2017 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
    IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
    IEC 60079-13:2017 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
    IEC 60079-26:2014 RLV Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
    EN 60034-5:2001/A1:2007 ROTATING ELECTRICAL MACHINES - PART 5: DEGREES OF PROTECTION PROVIDED BY THE INTEGRAL DESIGN OF ROTATING ELECTRICAL MACHINES (IP CODE) - CLASSIFICATION
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective