• UNE EN 61131-2 : 1997 A12 2001

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    PROGRAMMABLE CONTROLLERS - PART 2: EQUIPMENT REQUIREMENTS AND TEST

    Available format(s): 

    Superseded date:  01-05-2006

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Asociacion Espanola de Normalizacion

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 General
       1.1 Scope and object
       1.2 Compliance with this standard
       1.3 Normative references
    2 Type tests
       2.1 Equipment to be tested (equipment under test/EUT)
       2.2 Special features for immunity and EMC tests
       2.3 Withstand test conditions
       2.4 Verification procedure
       2.5 Requirements for test programmes and proper
           functioning verification procedures (PFVPs) to
           be provided by the manufacturer
       2.6 General conditions for tests
    3 Terms and definitions
    4 Normal service conditions and requirements
       4.1 Climatic conditions and requirements
       4.2 Mechanical service conditions and requirements
       4.3 Transport and storage conditions and requirements
       4.4 Electrical service conditions and requirements
       4.5 Special conditions and requirements
    5 Functional requirements
       5.1 Functional power supply and memory back-up requirements
       5.2 Digital I/Os
       5.3 Analogue I/Os
       5.4 Communication interface requirements
       5.5 Main processing unit(s) and memory(ies) of
           the PLC-system requirements
       5.6 Remote input/output stations (RIOSs) requirements
       5.7 Peripherals (PADTs, TEs, HMIs) requirements
       5.8 PLC-system self-tests and diagnostics requirements
       5.9 Functional earthing
       5.10 Mounting requirements
       5.11 General marking requirements
       5.12 Requirements for normal service and functional
            type tests and verifications
       5.13 Requirements for information on normal service
            and function
    6 Normal service and functional type tests and verifications
       6.1 Climatic tests
       6.2 Mechanical tests
       6.3 Verification of special functional requirements for
           power ports and memory back-up - Special immunity
           limits for power ports
       6.4 Verification of input/output requirements
       6.5 Verification of communication interface requirements
       6.6 Verification of MPU requirements
       6.7 Verification of remote I/O stations
       6.8 Verification of peripheral (PADTs, TEs, HMIs)
           requirements
       6.9 Verification of PLC-system self-tests and diagnostics
       6.10 Verification of markings and manufacturer's
            documentation
    7 General information to be provided by the manufacturer
       7.1 Information on type and content of documentation
       7.2 Information on compliance with this standard
       7.3 Information on reliability
       7.4 Information on other conditions
       7.5 Information on shipping and storage
       7.6 Information on a.c. and d.c. power supply
       7.7 Information on digital inputs (current sinking)
       7.8 Information on digital outputs for alternating
           currents (current sourcing)
       7.9 Information on digital outputs for direct current
           (current sourcing)
       7.10 Information on analogue inputs
       7.11 Information on analogue outputs
       7.12 Information on communication interfaces
       7.13 Information on main processing unit(s)
            and memory(ies) of the PLC-system
       7.14 Information on remote input/output stations (RIOSs)
       7.15 Information on peripherals (PADTs, TEs, HMIs)
       7.16 Information on self-tests and diagnostics
    8 Electromagnetic compatibility (EMC) requirements
       8.1 General
       8.2 Emission requirements
       8.3 EMC immunity requirements
       8.4 Requirements for EMC tests and verifications
       8.5 Requirements for information on EMC
    9 Electromagnetic compatibility (EMC) type tests and
       verifications
       9.1 Electromagnetic compatibility-related tests
       9.2 Test environment
       9.3 Measurement of radiated interference
       9.4 Measurement of conducted interference
       9.5 Electrostatic discharge
       9.6 Radiofrequency electromagnetic field - Amplitude
           modulated
       9.7 Power-frequency magnetic fields
       9.8 Fast transient bursts
       9.9 High-energy surges
       9.10 Conducted radiofrequency interference
       9.11 Damped oscillatory wave (for zone C only)
       9.12 Voltage drops and interruptions - Power
            port type tests and verifications
    10 Electromagnetic compatibility (EMC) information to be
       provided by the manufacturer
    11 Safety requirements
       11.1 Protection against electrical shock
       11.2 Protection against the spread of fire
       11.3 Limited power circuits
       11.4 Clearance and creepage distances requirements
       11.5 Flame-retardant requirements for non-metallic materials
       11.6 Temperature limits
       11.7 Enclosures
       11.8 Field-wiring terminals constructional requirements
       11.9 Provisions for protective earthing
       11.10 Wiring
       11.11 Switching devices
       11.12 Components
       11.13 Battery requirements
       11.14 Maximum voltage and minimum voltage
       11.15 Markings and identification
       11.16 Requirements for safety type tests and verifications
       11.17 Requirements for safety routine tests and verifications
       11.18 Requirements for information on safety
    12 Safety type tests and verifications
       12.1 Safety-related mechanical tests and verifications
       12.2 Safety-related electrical tests
       12.3 Single-fault condition test - General
    13 Safety routine tests
       13.1 Dielectric withstand test
       13.2 Dielectric withstand verification test
       13.3 Protective earthing test
    14 Safety information to be provided by the manufacturer
       14.1 Information on evaluation of enclosures for open
            equipment (power dissipation)
       14.2 Information on mechanical terminal connection
    Annex A (informative) Illustration of PLC-system hardware
            definitions
    Annex B (informative) Digital input standard operating range
            equations
    Annex C (normative) Test tools
    Annex D (informative) Zone C - EMC immunity levels
    Annex E (informative) Overvoltage example
    Annex ZA (normative) Normative references to international
             publications with their corresponding European
             publications
    Bibliography
    Figures
    Tables

    Abstract - (Show below) - (Hide below)

    Specifies requirements and related tests for programmable controllers (PLCs) and their associated peripherals, which have as their intended use the control and command of machines and industrial processes.

    General Product Information - (Show below) - (Hide below)

    Committee CTN 203
    Document Type Standard
    Publisher Asociacion Espanola de Normalizacion
    Status Superseded
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective