• UNI EN 14637 : 2008

    Current The latest, up-to-date edition.

    BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATION AND MAINTENANCE

    Available format(s): 

    Language(s): 

    Published date:  29-01-2008

    Publisher:  Ente Nazionale Italiano di Unificazione (UNI)

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviated term
    4 Classification
      4.1 Coding system
      4.2 Category of use (first digit)
      4.3 Durability (second digit)
      4.4 Door type (third digit)
      4.5 Suitability for use on fire/smoke door assemblies
          (fourth digit)
      4.6 Safety (fifth digit)
      4.7 Corrosion resistance (sixth digit)
      4.8 Example of classification
    5 Requirements and test methods for components of a
      hold-open system
      5.1 General
      5.2 Fire detectors
          5.2.1 Smoke detectors
          5.2.2 Heat detectors
          5.2.3 Resetting the detectors
      5.3 Power supply units
          5.3.1 All power supply units
          5.3.2 For power supply units with stand-by
                 parallel operation
      5.4 Control units
          5.4.1 General
          5.4.2 Control units in stand-alone hold-open systems
                 (single-line systems)
          5.4.3 Control units in fire detection and fire alarm
                 systems (multi-line systems)
      5.5 Hold-open devices
          5.5.1 General
          5.5.2 Hold-open devices for swing doors
          5.5.3 Hold-open devices for sliding doors, lifting doors,
                 industrial doors and roller shutters
          5.5.4 Automatic door operators
          5.5.5 Low energy/power assisted swing door
                 operators
          5.5.6 Free-swing door closers
      5.6 Auxiliary equipment
          5.6.1 Manual control push-buttons and switches
          5.6.2 Presence sensors (electro-sensitive protective
                 equipment)
          5.6.3 Door position sensors
          5.6.4 Remote indicating devices
          5.6.5 Manual reset
    6 Requirements for the hold-open system
      6.1 Design and performance
      6.2 Product information
          6.2.1 General
          6.2.2 For installation and maintenance
          6.2.3 For initial hold-open system test
      6.3 Requirements not covered under Clause 5
      6.4 Electromagnetic compatibility (EMC)
      6.5 Additional design requirements for connection of
          components to fire alarm systems
      6.6 Electrical safety
      6.7 Durability
      6.8 Environmental behaviour
          6.8.1 Dry heat
          6.8.2 Cold
          6.8.3 Damp heat, steady state (operational)
          6.8.4 Corrosion
          6.8.5 Vibration
      6.9 Supply voltage variations
    7 System tests
      7.1 General
      7.2 Test apparatus
      7.3 Theoretical analysis
      7.4 Test methods
          7.4.1 General
          7.4.2 Design verification
          7.4.3 Performance tests
          7.4.4 Check of switching device capabilities of
                 the control unit
          7.4.5 Short-circuit test
          7.4.6 Electrical safety tests
          7.4.7 Electromagnetic compatibility (EMC) tests
          7.4.8 Environmental tests
          7.4.9 Corrosion test
          7.4.10 Vibration test, sinusoidal (operational)
          7.4.11 Vibration test, sinusoidal (endurance)
    8 Marking
      8.1 Components
      8.2 Hold-open system
    Annex A (informative) - Recommendations for planning and
                            design of the hold-open system
            A.1 General
            A.2 Restrictions
            A.3 Detectors
                A.3.1 Selection of detector type
                A.3.2 Positioning and number of detectors
            A.4 Selection of hold-open device
                A.4.1 General
                A.4.2 Swing doors
                A.4.3 Sliding doors
                A.4.4 Roller shutter and lifting doors
                A.4.5 Automatic doors
            A.5 Manual release and manual control
                A.5.1 General
                A.5.2 Location of switch/push-button
            A.6 Interconnecting cables
            A.7 Guidance on competence and responsibilities
                for individual installations in individual
                buildings
                A.7.1 Planning
                A.7.2 Installation
    Annex B (informative) - Recommendations for installation and
                            fixing of the hold-open system
    Annex C (informative) - Recommendations for acceptance
                            inspection of the hold-open system
    Annex D (informative) - Acceptance inspection report form
    Annex E (informative) - Recommendations for usage and
                            maintenance of the hold-open system
            E.1 Usage of installations
                E.1.1 General
                E.1.2 Periodic inspection
            E.2 Routine site inspection report form
    Annex F (informative) - Evaluation of conformity
            F.1 General
                F.1.1 Introduction
                F.1.2 Initial type test
                F.1.3 Characteristics
                F.1.4 Use of historical data
                F.1.5 Treatment of calculated values and design
                F.1.6 Sampling, testing and conformity criteria
            F.2 Factory production control (FPC)
                F.2.1 General
                F.2.2 FPC requirements for all manufacturers
            F.3 Further testing of sample systems
                F.3.1 Periodic testing
                F.3.2 Yearly testing
                F.3.3 Manufacturer-specific FPC system requirements
    Annex G (informative) - Type test report and list of approved
                            components
            G.1 Test report
            G.2 List of approved components
    Annex H (informative) - Example methodology for theoretical
                            analysis
            H.1 Introduction
            H.2 Points for analysis
                H.2.1 General
                H.2.2 List of characteristics
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes requirements, methods of test and performance criteria against which the compatibility of components and their performance can be assessed when used in combination to form an electrically controlled hold-open system.

    General Product Information - (Show below) - (Hide below)

    Committee CT 33
    Document Type Test Method
    Publisher Ente Nazionale Italiano di Unificazione (UNI)
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNI 11473-1 : 2013 FIRE RESISTANCE AND/OR SMOKE CONTROL DOORS AND OPENABLE WINDOWS - PART 1: REQUIREMENTS FOR SERVICES SUPPLY OF INSTALLATION AND MAINTENANCE