    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements for immunity
    5 Immunity test procedures
    6 Measurement uncertainty
    Annex A (informative) - Background for establishing
            test methods, performance criteria and test levels
    Bibliography
    Annex ZA (normative) - Normative references to international
             publications with their corresponding European
             publications
    Annex ZZ (informative) - Coverage of Essential Requirements
             of EC Directives

    Abstract - (Show below) - (Hide below)

    Deals with all relevant EMC phenomena for hearing aids.

    Scope - (Show below) - (Hide below)

    IEC 60118-13:2011 in principle covers all relevant EMC phenomena for hearing aids. Hearing aid immunity to high frequency electromagnetic fields originating from digital wireless devices operating in the frequency ranges 0,8 GHz to 0,96 GHz and 1,4 GHz to 2,48 GHz is currently identified as the only relevant EMC phenomenon regarding hearing aids. Future editions of this part of IEC 60118 may add tests for other frequency bands, as they come into more common use. IEC 61000-4-3 is the basis for relevant EMC tests to be conducted on hearing aids. Measurement methods and acceptance levels are described in this part of IEC 60118. This third edition cancels and replaces the second edition published in 2004 and constitutes a technical revision. It introduces a new set of requirements for use of hearing aids with mobile phones.

    General Product Information - (Show below) - (Hide below)

    Committee EPL/29
    Development Note Supersedes 94/207289 DC. (09/2005) Supersedes 00/203722 DC (11/2005) Supersedes 07/30161929 DC & 08/30177361 DC. (08/2011)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    PD 6545:2005 Intended use of human head and ear simulators-guide

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60318-4:2010 Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts
    EN 60118-0:2015 Electroacoustics - Hearing aids - Part 0: Measurement of the performance characteristics of hearing aids
    IEC 60118-7:2005 Electroacoustics - Hearing aids - Part 7: Measurement of the performance characteristics of hearing aids for production, supply and delivery quality assurance purposes
    EN 60118-7:2005 Electroacoustics - Hearing aids - Part 7: Measurement of the performance characteristics of hearing aids for production, supply and delivery quality assurance purposes
    IEEE 488.2 : 1992 STANDARD CODES, FORMATS, PROTOCOLS, AND COMMON COMMANDS FOR USE WITH IEEE 488.1-1987, IEEE STANDARD DIGITAL INTERFACE FOR PROGRAMMABLE INSTRUMENTATION
    EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
    IEC 60318-5:2006 Electroacoustics - Simulators of human head and ear - Part 5: 2 cm3 coupler for the measurement of hearing aids and earphones coupled to the ear by means of ear inserts
    IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    IEC 60118-4:2014+AMD1:2017 CSV Electroacoustics - Hearing aids - Part 4: Induction-loop systems for hearing aid purposes - System performance requirements
    IEEE/ANSI C63.19-2011 REDLINE American National Standard Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids
    EN 60318-5 : 2006 ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 5: 2 CM[3] COUPLER FOR THE MEASUREMENT OF HEARING AIDS AND EARPHONES COUPLED TO THE EAR BY MEANS OF EAR INSERTS
    IEC 60118-0:2015 Electroacoustics - Hearing aids - Part 0: Measurement of the performance characteristics of hearing aids
    IEC 60118-2:1983 Hearing aids. Part 2: Hearing aids with automatic gain control circuits
    EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
    EN 60318-4:2010 Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts
    EN 60118-2:1995/A2:1997 HEARING AIDS - PART 2: HEARING AIDS WITH AUTOMATIC GAIN CONTROL CIRCUITS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective