• AS IEC 61260.1:2019

    Current The latest, up-to-date edition.

    Electroacoustics - Octave-band and fractional-octave-band filters Specifications

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English

    Published date:  02-05-2019

    Publisher:  Standards Australia

    Add To Cart

    Abstract - (Show below) - (Hide below)

    The objective of this Standard is to specify performance requirements for analogue, sampled-data, and digital implementations of band-pass filters.

    Scope - (Show below) - (Hide below)

    1.1 This part of the IEC 61260 series specifies performance requirements for analogue, sampled-data, and digital implementations of band-pass filters. The extent of the pass-band region of a filter's relative attenuation characteristic is a constant percentage of the exact midband frequency for all filters of a given bandwidth. An instrument conforming to the requirements of this standard may contain any number of contiguous band-pass filters covering any desired frequency range.
    1.2 Performance requirements are provided for two filter classes: class 1 and class 2. In general, specifications for class 1 and class 2 filters have the same design goals and differ mainly in the acceptance limits and the range of operational temperature. Acceptance limits for class 2 are greater than, or equal to, those for class 1. Maximum-permitted expanded uncertainties of measurement are also specified.
    1.3 Performance requirements are given for designs where the octave frequency ratio and the mid-band frequencies are powers of ten.
    1.4 Band-pass filters conforming to the performance requirements of this standard may be part of various measurement systems or may be an integral component of a specific instrument such as a spectrum analyser.
    1.5 This standard specifies the ranges of environmental conditions for operation of the filters. The required range depends on whether the instrument containing the filters is designed to be operated in a controlled environment or more generally in the field.
    1.6 Band-pass filters conforming to the requirements of this standard are capable of providing frequency-band-filtered spectral information for a wide variety of signals, for example, time-varying, intermittent or steady; broadband or discrete frequency; and long or short durations.

    General Product Information - (Show below) - (Hide below)

    Committee EV-010
    Document Type Standard
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    Originated in Australia as AS Z41—1969.
    Originated in New Zealand as NZS 1499:1965.
    AS Z41—1969 and NZS 1499:1965 jointly revised, amalgamated and redesignated AS/NZS 4476:1997.
    This edition revised in part and redesignated as AS IEC 61260.1:2019. Originated in Australia as AS Z41-1969. Originated in New Zealand as NZS 1499:1965. AS Z41-1969 and NZS 1499:1965 jointly revised, amalgamated and redesignated AS/NZS 4476:1997. This edition revised in part and redesignated as AS IEC 61260.1:2019.

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
    IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
    IEC 61000-6-1 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS
    IEC 61672-1:2013 Electroacoustics - Sound level meters - Part 1: Specifications
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
    IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
    CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
    ISO/IEC Guide 98-4:2012 Uncertainty of measurement Part 4: Role of measurement uncertainty in conformity assessment
    IEC 61000-6-3:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective