• API 343 : 1998

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    FUGITIVE EMISSIONS FROM EQUIPMENT LEAKS 2: CALCULATION PROCEDURES FOR PETROLEUM INDUSTRY FACILITIES

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  30-01-2024

    Language(s):  English

    Published date:  01-07-1998

    Publisher:  American Petroleum Institute

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1.0 Introduction
    2.0 Equipment Description
          2.1 Equipment Types
                2.1.1 Agitators
                2.1.2 Compressors
                2.1.3 Connectors
                2.1.4 Open-ended Lines
                2.1.5 Pressure Relief Devices
                2.1.6 Pumps
                2.1.7 Sampling Connections
                2.1.8 Valves
                2.1.9 Others
          2.2 Counting Components
                2.2.1 Agitators
                2.2.2 Compressors
                2.2.3 Connectors
                2.2.4 Open-ended Lines
                2.2.5 Pressure Relief Devices
                2.2.6 Pump Seals
                2.2.7 Sampling Connections
                2.2.8 Valves
                2.2.9 Others
    SECTION 3.0 Emission Estimation Methods
          3.1 Average Emission Factor Method
                3.1.1 Reduction Factors
                3.1.2 Adjustment for Inorganics
                3.1.3 Adjustment for Non-VOC Organic Compounds
                3.1.4 Adjustment for Methane at Refineries for Total
                       Organic Compounds
                3.1.5 Sample Calculation Using Average Emission Factor
                       Method
          3.2 Screening Ranges Method
                3.2.1 Sample Calculations Using Screeeing Ranges Method
                3.2.2 Sample Calculations Applying Non-VOC Organic
                       Compounds and Methane Adjustment to Screening Ranges
                       Method
          3.3 Emission Correlation Equation Method
                3.3.1 Sample Calculation Using Emission Correlation Equation
                       Method
          3.4 Emission Estimation Methods for Petrochemical Facilities
          3.5 Estimating Equipment Leak Emissions of Inorganic Compounds
    SECTION 4.0 Issues Affecting Determination of Emissions
          4.1 Size of a Component
          4.2 Use of Background Hydrocarbon Levels
          4.3 Use of Response Factors
          4.4 Analyzer Correction Factors
          4.5 Length of Time to Consider a Component Leaking
                4.5.1 Immediately After Last Monitoring
                4.5.2 Immediately Prior to Most Recent Monitoring
                4.5.3 Average Between Monitorings
                4.5.4 Prior to Any Monitoring
          4.6 Emission Factors for New Emission Sources
          4.7 Stream Speciation
          4.8 Calculating Emissions from Inaccessible and Difficult-to-
                Monitor Components
          4.9 Impact of Temperature and Pressure on Emissions
          5.0 Data Management
          6.0 References
    Appendix A: Component Count Estimation Methods for Refinery Units
    Appendix B: Method to Account for Benefits of an Inspection/Maintenance
                 Program for Fugitive Emissions
    Appendix C: SOCMI Fugitive Emission Factors and Equations
    Appendix D: Response Factors
    Appendix E: Response Factor Calculation Example
    List of Figures
    2-1 Threaded Connector Elbow
    2-2 Ball Valve with Side Flanges
    4-1 Example of Options for Length of Time to Consider a Component
         Leaking

    Abstract - (Show below) - (Hide below)

    Covers emission calculations associated with fugitive emissions. Providing an overview of emission estimation approaches, it also includes sample calculations for various calculation methods.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Product Note This product is unavailable in Cuba, Iran, North Korea, Syria
    Publisher American Petroleum Institute
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    API 500 : 2012 RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2
    API RP 500:2023 Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class I, Division 1 and Division 2
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective