AS 4436-1996
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Guide for the selection of insulators in respect of polluted conditions
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
27-11-2020
English
01-01-1996
Provides guidance on the selection of insulators for use in polluted conditions. It is identical with and has been reproduced from IEC 815:1986.
Committee |
EL-010
|
DocumentType |
Standard
|
ISBN |
0 7337 0808 0
|
Pages |
19
|
ProductNote |
Reconfirmed 27/05/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This guide is mainly applicable to three-phase systems up to 525 kV (phase-to-phase). For higher voltages the possible non-linear performance of insulators is still under study.This guide is applicable to outdoor ceramic and glass insulators, used in a.c. systems, of the following types:- long-rod and traction line insulator;- cap and pin insulator;- pedestal type post and rigid pin insulator;- substation and line post insulator;- hollow insulator;- bushing.This guide cannot directly be used for special types of insulators such as insulators with conductive glaze, or covered, during the manufacturing, with any insulating material, for surge arresters and also for longitudinal insulation for open circuit-breakers. This guide does not deal with radio interference voltage, television interference voltage and audible noise, the intensity of which may be increased on some polluted insulators.
Standards | Relationship |
IEC TR 60815:1986 | Identical |
First published as AS 4436-1996.
AS 2947.2-1989 | Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. Characteristics |
AS 1824.2-1985 | Insulation coordination (phase-to-earth and phase-to-phase, above 1 kV) - Application guide |
AS 1137.3-1981 | Insulators - Porcelain and glass indoor and outdoor station post insulators (for voltages greater than 1000 V a.c.) |
AS/NZS 2947.2:2002 | Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. |
AS 60076.1-2005 | Power transformers General (IEC 60076-1, Ed. 2.1 (2000) MOD) |
AS 60044.2-2007 | Instrument transformers Inductive voltage transformers (IEC 60044-2:Ed.1.2 (2003) MOD) |
AS 3007.2-2004 | Electrical installations - Surface mines and associated processing plant - General protection requirements |
AS/NZS 7000:2016 | Overhead line design |
AS/NZS 60137:2008 | Insulated bushings for alternating voltages above 1000 V (IEC 60137, Ed. 5.0 (2003) MOD) |
AS 62217-2007 | Polymeric insulators for indoor and outdoor use with a nominal voltage > 1000 V - General definitions, test methods and acceptance criteria |
AS 60044.1-2007 | Instrument transformers Current transformers (IEC 60044-1 Ed.1.2 (2003) MOD) (Reconfirmed 2016) |
AS/NZS 2947.2:2002 | Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. |
AS 4899-2007 | Pin insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. (Reconfirmed 2018) |
HB 331-2012 | Overhead line design |
AS/NZS 2947.1:1999 | Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. Test methods - Insulator units |
AS/NZS 2650:2000 | Common specifications for high-voltage switchgear and controlgear standards |
AS 2067-2008 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 60305-2007 | Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass insulator units for a.c. systems - Characteristics of insulator units of the cap and pin type |
AS 60044.5-2004 | Instrument transformers Capacitor voltage transformers |
AS 62271.202-2008 | High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation |
AS/NZS 7000:2010 | Overhead line design - Detailed procedures |
AS IEC 60433-2007 | Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic insulators for a.c. systems - Characteristics of insulator units of the long rod type |
AS 4398.2-2005 | Insulators - Ceramic or glass - Station post for indoor or outdoor use - Voltages greater than 1000 V a.c. Tests (IEC 60168, Ed. 4.2 (2001) MOD) |
AS 2650-2005 | Common specifications for high-voltage switchgear and controlgear standards (IEC 60694 Ed.2.2(2002) MOD) |
AS 4435.4-1997 | Insulators - Composite for overhead power lines - Voltages greater than 1000 V a.c. Definitions, test methods and acceptance criteria for post insulator units |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.