• AS/NZS 1905.1:1997

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Components for the protection of openings in fire-resistant walls Fire-resistant doorsets

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  24-06-2021

    Language(s):  English

    Published date:  05-03-1997

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS/NZS 1905.1:1997 COMPONENTS FOR THE PROTECTION OF OPENINGS IN FIRE-RESISTANT WALLS - FIRE-RESISTANT DOORSETS
    4 - PREFACE
    5 - CONTENTS
    7 - SECTION 1 SCOPE AND GENERAL
    7 - 1.1 SCOPE
    7 - 1.2 APPLICATION
    7 - 1.3 OBJECTIVE
    8 - 1.4 REFERENCED DOCUMENTS
    9 - 1.5 DEFINITIONS
    9 - 1.5.1 Approved
    9 - 1.5.2 Asymmetric leaf
    9 - 1.5.3 Automatic
    9 - 1.5.4 Backset
    9 - 1.5.5 Building Code
    9 - 1.5.6 Certifier
    9 - 1.5.7 Combustible
    9 - 1.5.8 Doorset
    9 - 1.5.9 Doorstop
    9 - 1.5.10 Double-acting doorset
    9 - 1.5.11 Essential latching components
    9 - 1.5.12 Facings and edgings
    10 - 1.5.13 Fire-resistance level (FRL)
    10 - 1.5.14 Fire-resistant doorset
    10 - 1.5.15 Formal opinion
    10 - 1.5.16 Full-scale test
    10 - 1.5.17 Furniture (door)
    10 - 1.5.18 Hardware (door)
    10 - 1.5.19 Heat-actuated device
    10 - 1.5.20 Latch handle
    10 - 1.5.21 Manufacturer
    10 - 1.5.22 Mullion
    10 - 1.5.23 Pilot test
    10 - 1.5.24 Recognized authority
    11 - 1.5.25 Registered testing authority
    11 - 1.5.26 Regulatory authority
    11 - 1.5.27 Self-closing
    11 - 1.5.28 Similar construction
    11 - 1.5.29 Specimen doorset
    11 - 1.5.30 Sponsor
    11 - 1.5.31 Standard fire test
    11 - 1.5.32 Tested specimen
    11 - 1.5.33 Through components
    11 - 1.5.34 Transom panel
    11 - 1.5.35 Walls of concrete construction
    11 - 1.5.36 Walls of masonry construction
    15 - SECTION 2 DESIGN REQUIREMENTS
    15 - 2.1 GENERAL
    15 - 2.1.1 Materials
    15 - 2.1.2 Self-closure
    15 - 2.1.3 Selection of hardware
    15 - 2.1.4 Clearances
    15 - 2.1.5 Wall openings
    15 - 2.1.6 Sensing device
    16 - 2.2 SIDE-HUNG DOORS, INCLUDING DOUBLE-ACTING DOORSETS
    16 - 2.2.1 Width of door seat rebate
    16 - 2.2.2 Hinges and pivots
    16 - 2.2.3 Materials for essential latching components
    16 - 2.2.4 Closer pressure relief
    16 - 2.2.5 Cushioned back-checking action of the closer
    17 - 2.2.6 Security latching
    17 - 2.3 SLIDING DOORSETS
    17 - 2.3.1 Flush pulls and grips
    17 - 2.3.2 Directional arrows
    17 - 2.3.3 Automatic closing
    20 - SECTION 3 DETERMINATION OF FIRE RESISTANCE
    20 - 3.1 GENERAL
    20 - 3.2 TEST MOUNTING
    20 - 3.3 EXPOSURE TO FIRE
    20 - 3.3.1 Side-hung doors
    21 - 3.3.2 Sliding doors
    21 - 3.4 VISION PANEL
    21 - 3.5 LATCHSET
    22 - SECTION 4 VARIATIONS FROM THE TESTED SPECIMEN
    22 - 4.1 GENERAL
    22 - 4.2 VARIATIONS PERMITTED WITHOUT A FORMAL OPINION
    22 - 4.2.1 Decrease in size of opening
    22 - 4.2.2 Door leaf
    22 - 4.2.3 Timber used in doorset
    22 - 4.2.4 Door frame
    22 - 4.2.5 Wall of masonry or concrete construction
    22 - 4.2.6 Hardware
    24 - 4.3 VARIATIONS PERMITTED SUBJECT TO A FORMAL OPINION
    24 - 4.3.1 General
    24 - 4.3.2 Preparation and presentation of formal opinions
    25 - 4.3.3 Minimum fire-testing required for the preparation of formal opinions
    28 - SECTION 5 INSTALLATION
    28 - 5.1 GENERAL
    28 - 5.2 DOORSILLS
    28 - 5.2.1 General
    28 - 5.2.2 New Zealand
    28 - 5.3 FIXING OF DOOR FRAMES
    28 - 5.4 ALLOWABLE VARIATIONS FOR FIXING OF DOOR FRAMES
    29 - 5.5 CLEARANCES
    29 - 5.5.1 General
    29 - 5.5.2 Sill and floor finish
    29 - 5.5.3 Side hung doors, leaf to frame
    29 - 5.5.4 Double-acting doorsets
    29 - 5.5.5 Horizontally sliding doorsets
    29 - 5.6 HARDWARE
    29 - 5.6.1 Attachment
    30 - 5.6.2 Latch handles
    30 - 5.6.3 Sensing devices
    30 - 5.6.4 Travel-limiting devices
    30 - 5.6.5 Counterweighting system for sliding doors
    30 - 5.7 FINAL CHECK
    33 - SECTION 6 MARKING AND OTHER DOCUMENTATION
    33 - 6.1 MARKING OF FIRE-RESISTANT DOORSETS
    33 - 6.1.1 General
    33 - 6.1.2 Completed installation
    33 - 6.1.3 Metal tags
    34 - 6.1.4 Information requirements
    35 - 6.2 MARKING OF LATCHSETS AND CLOSERS-AUSTRALIA
    35 - 6.2.1 General
    35 - 6.2.2 Latchset
    36 - 6.2.3 Closer body
    36 - 6.3 EVIDENCE OF COMPLIANCE - AUSTRALIA
    36 - 6.3.1 Installation
    36 - 6.3.2 Schedule of evidence of compliance
    36 - 6.3.3 Records and required information
    37 - 6.4 EVIDENCE OF COMPLIANCE - NEW ZEALAND
    37 - 6.4.1 Attachment
    37 - 6.4.2 Further evidence to be provided
    37 - 6.4.3 Register
    37 - 6.5 FIRE-RESISTANT DOORSET SIGNS - NEW ZEALAND
    37 - 6.5.1 Installation
    37 - 6.5.2 Size
    37 - 6.6 MAINTENANCE
    38 - APPENDIX A - PHYSICAL TESTING OF FIRE-RESISTANT DOORSETS
    38 - A1 SCOPE
    38 - A2 PRINCIPLE
    38 - A3 APPARATUS
    38 - A4 SPECIMEN
    38 - A5 TEST METHODS
    38 - A5.1 General
    38 - A5.2 Resistance to buckling (torsion)
    38 - A5.3 Vertical loading test
    39 - A5.4 Resistance to slamming
    39 - A5.5 Shock impact
    39 - A5.6 Body impact
    39 - A5.7 Resistance to misuse
    40 - A6 TEST REPORT
    41 - APPENDIX B - INFORMATION TO BE SUPPLIED WITH ENQUIRIES AND ORDERS
    44 - APPENDIX C - SUPPLEMENTARY NOTES ON THE SELECTION OF DOOR CLOSERS FOR FIRE-RESISTANT DOORSETS
    45 - APPENDIX D - METHODS FOR FIXING FIRE-RESISTANT DOOR FRAMES TO EXISTING WALLS OF CONCRETE OR MASONRY
    45 - D1 GENERAL
    45 - D2 METHODS
    45 - D2.1 General
    45 - D2.2 Fixing the doorset frame by means of bonded hairpin anchors
    46 - D2.3 Fixing the doorset frame by means of threaded anchors
    49 - APPENDIX E - FIRE DOOR CERTIFICATE AND SCHEDULE OF EVIDENCE OF COMPLIANCE

    Abstract - (Show below) - (Hide below)

    Specifies requirements for the design, construction and installation of fire-resistant doorsets including transom panels but excluding lift-landing doors and access panels, used to protect openings in walls and partitions required to resist the passage of fire. Shows the variation between Australia and New Zealand in regard to the certification, marking and identification of doorsets as determined by the building codes and practice in both countries. A series of tests by which the physical capacity of the doorsets may be measured is also included.

    Scope - (Show below) - (Hide below)

    This Standard specifies requirements for the construction and installation of fire-resistant doorsets used to protect openings in walls and partitions which are required to resist the passage of fire.This Standard also applies to transom panels over doors, where the panels are contained within the doorframe and form part of the doorset.This Standard does not apply to lift-landing doors.NOTES:1 Where it is intended to install the fire-resistant doorset in high traffic areas, it is recommended that it be tested in accordance with Appendix A prior to fire testing and that it complies with the requirements set out therein.2 Durability designations for locksets and methods for their cycle testing, for minimal, moderate and high frequency usage, are given in AS 4145.2.3 Manufacturers of fire-resistant doorsets are strongly encouraged to implement quality control systems in accordance with AS/NZS ISO 9002.Guidance on the introduction and maintenance of suitable quality systems is given in AS/NZS ISO 9000 and AS/NZS ISO 9004.4 Guidance on information that should be supplied with an enquiry or order is given in Appendix B.5 Requirements governing lift-landing doors are given in AS 1735.11 or NZS 4332P, as applicable.6 A panel above a doorset, which is not contained within the door frame, is considered as being part of the wall and is therefore subject to the structural adequacy, integrity and insulation requirements set out in the Building Code.7 A transom or mullion within a door frame may be permanently fixed to the side members of the frame or may be removable by means of mechanical fixing.8 A smoke control system (or other external environmental conditions) can impose forces greater than 5 N on the strike. In such circumstances a substantially greater resistance force may be required of the strike to ensure the door remains in the latched position during a fire emergency.

    General Product Information - (Show below) - (Hide below)

    Committee FP-019
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published in Australia as AS CA57.1-1972.Revised and redesignated AS 1905.1-1976.Second edition 1982.Third edition 1984.Fourth edition 1990.First published in New Zealand as part of NZS 1188:1954.Revised and redesignated in part as NZS 4232.1:1988.AS 1905.1-1990 and NZS 4232.1:1988, jointly revised, amalgamated and designated AS/NZS 1905.1:1997. First published in Australia as AS CA57.1-1972. Revised and redesignated AS 1905.1-1976. Second edition 1982. Third edition 1984. Fourth edition 1990. First published in New Zealand as part of NZS 1188:1954. Revised and redesignated in part as NZS 4232.1:1988. AS 1905.1-1990 and NZS 4232.1:1988, jointly revised, amalgamated and designated AS/NZS 1905.1:1997.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS/NZS ISO 9004:2000 Quality management systems - Guidelines for performance improvements
    AS 1530.1-1994 Methods for fire tests on building materials, components and structures Combustibility test for materials (Reconfirmed 2016)
    AS 4085-1992 Automatic sliding door assemblies
    AS/NZS ISO 9002:1994 Quality systems - Model for quality assurance in production, installation and servicing
    AS 1530.3-1989 Methods for fire tests on building materials, components and structures Simultaneous determination of ignitability, flame propagation, heat release and smoke release
    AS 1851.7-1984 Maintenance of fire protection equipment - Fire-resistant doorsets
    AS 1603.2-1997 Automatic fire detection and alarm systems Point type smoke detectors (Reconfirmed 2016)
    AS 1670-1986 Automatic fire detection and alarm systems - System design, installation, and commissioning
    AS 1428.1-1993 Design for access and mobility General requirements for access - Buildings
    AS 1735.11-1986 SAA Lift Code Fire-rated landing doors
    AS 2271-1979 Plywood and blockboard for exterior use
    AS/NZS ISO 9000:2000 Quality management systems - Fundamentals and vocabulary
    AS 1890-1999 Thermally released links (Reconfirmed 2016)
    AS B194-1970 Tapping and metallic drive screws
    AS 3600-1994 Concrete structures
    AS 2484.1-1990 Fire - Glossary of terms Fire tests (Reconfirmed 2016)
    AS 1603.1-1997 Automatic fire detection and alarm systems Heat detectors (Reconfirmed 2016)
    AS 2270-1979 Plywood and blockboard for interior use
    AS 1530.4-1990 Methods for fire tests on building materials, components and structures Fire-resistance tests of elements of building construction
    AS 3700-1988 Masonry in buildings (known as the SAA Masonry Code)
    AS 4145.2-1993 Locksets - Mechanical locksets for doors in buildings
    AS 4145.1-1993 Locksets - Glossary of terms

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 2896-1998 Medical gas systems - Installation and testing of non-flammable medical gas pipeline systems
    AS 1940-2004 The storage and handling of flammable and combustible liquids
    AS/NZS 1668.1:1998 The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings
    AS 1851-2005 Maintenance of Fire Protection Systems and Equipment
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective