• BS 7870-6.1:1999

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations PVC insulated and PVC sheathed cables

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  19-06-2014

    Language(s):  English

    Published date:  12-02-2004

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    1 Scope
    2 References
    3 Voltage designation
    4 General requirements
    5 Cables without metallic covering
    6 Cables with metallic covering
    Annex A (informative) Guide to use
    Bibliography
    Tables

    Abstract - (Show below) - (Hide below)

    Defines requirements and dimensions of single and multicore PVC insulated and sheathed cables with reduced fire propagation performance. Intended for a maximum continuous operating temperature of 70 degrees C and a maximum short-circuit temperature of 160 degrees C for conductor sizes not exceeding 300 m and 140 degrees C for larger sizes.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/16
    Development Note Supersedes 02/209792 DC and 96/204692 DC To be read in conjunction with BS 7870-1(1996) and BS 7870-2(1999). (02/2004) Inactive for the new design. (01/2012)
    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    HD 622 S1:1996/A2:2005 Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
    BS 4066:1969 Flame retardant characteristics of electric cables
    HD 627 S1:1996/A2:2005 MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND
    HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
    BS ISO 4589-2 : 1996 AMD 10627 PLASTICS - DETERMINATION OF BURNING BEHAVIOUR BY OXYGEN INDEX - AMBIENT-TEMPERATURE TEST
    HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
    HD 626 S1:1996/A2:2002 OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV
    HD 308 S2:2001 Identification of cores in cables and flexible cords
    IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
    BS EN 50265-2-1:1999 Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame
    BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective