BS 7889:2012
Current
The latest, up-to-date edition.
Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations
Hardcopy , PDF
English
31-10-2012
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Rated voltage
5 Conductors
6 Insulation
7 Identification of cores
8 Laying up
9 Extruded optional inner covering
10 Sheath
11 Cable marking and additional information
12 Schedule of tests
13 Test conditions
14 Routine tests
15 Sample tests
16 Type tests
Annexes
Annex A (informative) - Guide to use
Annex B (normative) - Compatibility test
Annex C (normative) - Abrasion test
Annex D (informative) - Notes on type tests
Annex E (normative) - Green-and-yellow measurement
for shaped conductors
Bibliography
Describes requirements and test methods for the construction and performance of non-armoured cables with thermosetting insulation of rated voltages 600/1000 V.
Committee |
GEL/20/17
|
DevelopmentNote |
Supersedes BS 7889(1997) & 12/30244369 DC. (10/2012)
|
DocumentType |
Standard
|
Pages |
32
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard specifies requirements and test methods for the construction and performance of non-armoured cables with thermosetting insulation of rated voltages 600/1000V. Cables specified in this British Standard are intended for use in fixed installations in industrial areas, buildings and similar applications but not for burial in the ground, either directly or in ducts.
The cables specified in the standard are all stranded copper conductor, thermosetting insulated, PVC sheathed types. There are single-core types, and multi-core types (2-, 3-, 4- and 5-core).
The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 90°C and for a maximum short-circuit conductor temperature of 250°C (for a maximum period of 5s).
NOTE1 Limitation on the temperature of the cables may be imposed in situations where they could be touched, or where they could touch other materials.
NOTE2 In installations that include wiring accessories, junction boxes and consumer units, etc., the performance of these accessories should be taken into account in deciding the maximum operating temperature of the cable.
NOTE3 AnnexA gives guidance on the use of these cables, AnnexB gives the compatibility test, AnnexC gives the abrasion test, AnnexD gives notes on type tests and AnnexE gives green-and-yellow measurement for shaped conductors.
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 8573:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 60811-401:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Miscellaneous tests. Thermal ageing methods. Ageing in an air oven |
BS EN 60229:2008 | Electric cables. Tests on extruded oversheaths with a special protective function |
BS EN 50262:1999 | Cable glands for electrical installations |
BS EN 60811-502:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for insulations |
BS EN 61914:2016 | Cable cleats for electrical installations |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
BS EN 60332-1-2 : 2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004) |
BS EN 50393:2015 | Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV |
BS EN 60228:2005 | Conductors of insulated cables |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 62275:2015 | Cable management systems. Cable ties for electrical installations |
BS EN 60079-14:2014 | Explosive atmospheres Electrical installations design, selection and erection |
BS EN 60811-501 : 2012 | ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 501: MECHANICAL TESTS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES OF INSULATING AND SHEATHING COMPOUNDS |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
BS EN 50395 : 2005 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
BS EN 62230 : 2007 | ELECTRIC CABLES - SPARK-TEST METHOD |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
BS EN 50363-5 : 2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
BS EN 50396 : 2005 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
BS 8512:2008 | Electric cables. Code of practice for the storage, handling, installation and disposal of cables on wooden drums |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.