    1 General
        1.1 Scope
        1.2 Normative references
        1.3 Definitions
    SECTION 1: MEASURING APPARATUS
    2 Quasi-peak measuring receivers for the frequency
        range 9 kHz to 1000 MHz
    3 Peak measuring receivers for the frequency range
        9 kHz to 1000 MHz
    4 Average measuring receivers for the frequency range
        9 kHz to 1000 MHz
    5 RMS measuring receivers for the frequency range 9 kHz
        to 1000MHz
    6 Spectrum analyzers and scanning receivers
    7 Audio-frequency voltmeter
    8 Reserved
    9 Reserved
    10 Reserved
    SECTION 2: ANCILLARY APPARATUS
    11 Artificial mains networks
    12 Current and voltage probes
    13 Absorbing clamp for use in the frequency range 30 MHz
        to 1000 MHz
    14 Disturbance analyzers
    15 Antennas for measurement of radiated radio disturbance
    16 Test sites for measurement of radio disturbance field
        strength for the frequency range of 30 MHz to 1000MHz
    17 Reverberating chamber for total radiated power
        measurement
    18 Coupling units for conducted current immunity measurement
    19 TEM cells for immunity to radiated disturbance
        measurement
    20 Coupling devices for measuring signal lines
    21 The artificial hand and series RC element
    A Determination of response to repeated pulses of
        quasi-peak and r.m.s. receivers
    B Determination of pulse generator spectrum
    C Accurate measurements of the output of nanosecond
        pulse generators
    D Influence of the quasi-peak measuring receiver
        characteristics upon its pulse response
    E Response of average and peak measuring receivers
    F Artificial mains networks
    G Validation procedure of the open area test site for the
        frequency range of 30 MHz to 1000 MHz
    H Calibration of the absorbing clamp
    J Construction, frequency range and calibration of
        current probes
    K Construction of the absorbing clamp
    L Construction details for open area test sites in the
        frequency range of 30 MHz to 1000 MHz
    M Basis for 4 dB site acceptability criterion
    N Construction of the coupling units for current injection
        for the frequency range 0.15 MHz
    P Principle of operation and examples of coupling units
        for conducted current immunity measurements
    Q Parameters of broadband antennas
    R Loop antenna system for magnetic field induced current
        measurements in the frequency range of 9 kHz to 30 MHz
    S Example of an asymmetrical artificial network (T-network)
    Figures 1 to S.4

    Abstract - (Show below) - (Hide below)

    Specifies characteristics and performance of equipment for measuring RF disturbance voltages, currents and fields in the frequency range 9 kHz to 18 GHz.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/210
    Development Note Supersedes BS 727(1983). (09/2005)
    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60315-3:1989+AMD1:1999 CSV Methods of measurement on radio receivers for various classes of emission - Part 3: Receivers for amplitude-modulated sound-broadcasting emissions
    CISPR 16-2:2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2: Methods of measurement of disturbances and immunity
    IEC 60315-4:1997 Methods of measurement on radio receivers for various classes of emission - Part 4: Receivers for frequency-modulated sound broadcasting emissions
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective