BS EN 1364-3:2014

Current

Current

The latest, up-to-date edition.

Fire resistance tests for non-loadbearing elements Curtain walling. Full configuration (complete assembly)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-01-2014

€322.53
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
6 Test specimen
7 Installation of the test specimen
8 Conditioning
9 Application of instrumentation
10 Test procedure
11 Performance criteria
12 Test report
13 Field of direct application of test results
Annex A (normative) - Field of direct application
        of test results for unitised construction
Annex B (informative) - Explanatory notes
Bibliography

Describes a method for determining the fire resistance of curtain walling - full configuration.

Committee
FSH/22/-/7
DevelopmentNote
Supersedes 11/30252458 DC. (02/2014)
DocumentType
Standard
Pages
68
PublisherName
British Standards Institution
Status
Current
Supersedes

This European Standard specifies a method for determining the fire resistance of curtain walling – full configuration.

This European Standard is used in conjunction with EN 1363-1.

NOTE Annex B gives further information on the test method.

The test method is applicable to curtain walling type B (for definition see 3.4). The test is not appropriate for testing curtain walling type A (for definition see 3.3).

The fire resistance of curtain walling may be determined under internal or external exposure conditions. In the latter case the external fire exposure curve given in EN 1363-2 may be used, subject to deviating national regulations.

Tests on individual parts of a curtain wall ing (e.g. perimeter seal, infill panel or fixing of the framing system (anchoring) used to attach the curtain walling to the floor element) or systems with fire resistance requirements only to the spandrel area may be performed using EN 1364-4. For vertical linear gap seals, this part of the standard applies.

This European Standard does not cover double skin façades, over -cladding systems and ventilated façade systems on external walls. It does not deal with the reaction to fire behaviour of curtain walling .

This standard is intended to be read in conjunction with EN 1363-1 and EN 1363-2.

Standards Relationship
UNI EN 1364-3 : 2014 Identical
NBN EN 1364-3 : 2014 Identical
EN 1364-3:2014 Identical
SN EN 1364-3 : 2014 Identical
DIN EN 1364-3:2014-05 Identical
I.S. EN 1364-3:2014 Identical
NEN EN 1364-3 : 2014 Identical
UNE-EN 1364-3:2015 Identical
NF EN 1364-3 : 2014 Identical
NS EN 1364-3 : 2014 Identical

PD 7974-3:2011 Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin
BS 476-10:2009 Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs

EN 1364-1:1999 Fire resistance tests for non-loadbearing elements - Part 1: Walls
ISO 13943:2017 Fire safety — Vocabulary
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
EN 13830:2015 Curtain walling - Product standard
EN 1364-4:2014 Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 13119:2016 Curtain walling - Terminology
EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures