BS EN 1364-3:2014
Current
The latest, up-to-date edition.
Fire resistance tests for non-loadbearing elements Curtain walling. Full configuration (complete assembly)
Hardcopy , PDF
English
31-01-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
6 Test specimen
7 Installation of the test specimen
8 Conditioning
9 Application of instrumentation
10 Test procedure
11 Performance criteria
12 Test report
13 Field of direct application of test results
Annex A (normative) - Field of direct application
of test results for unitised construction
Annex B (informative) - Explanatory notes
Bibliography
Describes a method for determining the fire resistance of curtain walling - full configuration.
Committee |
FSH/22/-/7
|
DevelopmentNote |
Supersedes 11/30252458 DC. (02/2014)
|
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies a method for determining the fire resistance of curtain walling – full configuration.
This European Standard is used in conjunction with EN 1363-1.
NOTE Annex B gives further information on the test method.
The test method is applicable to curtain walling type B (for definition see 3.4). The test is not appropriate for testing curtain walling type A (for definition see 3.3).
The fire resistance of curtain walling may be determined under internal or external exposure conditions. In the latter case the external fire exposure curve given in EN 1363-2 may be used, subject to deviating national regulations.
Tests on individual parts of a curtain wall ing (e.g. perimeter seal, infill panel or fixing of the framing system (anchoring) used to attach the curtain walling to the floor element) or systems with fire resistance requirements only to the spandrel area may be performed using EN 1364-4. For vertical linear gap seals, this part of the standard applies.
This European Standard does not cover double skin façades, over -cladding systems and ventilated façade systems on external walls. It does not deal with the reaction to fire behaviour of curtain walling .
This standard is intended to be read in conjunction with EN 1363-1 and EN 1363-2.
Standards | Relationship |
UNI EN 1364-3 : 2014 | Identical |
NBN EN 1364-3 : 2014 | Identical |
EN 1364-3:2014 | Identical |
SN EN 1364-3 : 2014 | Identical |
DIN EN 1364-3:2014-05 | Identical |
I.S. EN 1364-3:2014 | Identical |
NEN EN 1364-3 : 2014 | Identical |
UNE-EN 1364-3:2015 | Identical |
NF EN 1364-3 : 2014 | Identical |
NS EN 1364-3 : 2014 | Identical |
PD 7974-3:2011 | Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin |
BS 476-10:2009 | Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs |
EN 1364-1:1999 | Fire resistance tests for non-loadbearing elements - Part 1: Walls |
ISO 13943:2017 | Fire safety — Vocabulary |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 13830:2015 | Curtain walling - Product standard |
EN 1364-4:2014 | Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
EN 1363-1:2012 | Fire resistance tests - Part 1: General Requirements |
EN 13119:2016 | Curtain walling - Terminology |
EN 1363-2:1999 | Fire resistance tests - Part 2: Alternative and additional procedures |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.