• BS EN ISO 11137-1:2015+A2:2019

    Current The latest, up-to-date edition.

    Sterilization of health care products. Radiation Requirements for development, validation and routine control of a sterilization process for medical devices

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  27-11-2019

    Publisher:  British Standards Institution

    Add To Cart

    Abstract - (Show below) - (Hide below)

    The British Standards InstitutionThis part of ISO 11137 specifies requirements for the development, validation and routine control of a radiation sterilization process for medical devices.

    Scope - (Show below) - (Hide below)

    1.1 This part of ISO11137 specifies requirements for the development, validation and routine control of a radiation sterilization process for medical devices. NOTE Although the scope of this part of ISO11137 is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other products and equipment. This part of ISO11137 covers radiation processes employing irradiators using, the radionuclide60Co or137Cs, a beam from an electron generator or a beam from an X-ray generator. 1.2 This part of ISO11137 does not specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeld-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents. NOTE See, for example, ISO22442‑1 , ISO22442‑2 and ISO22442‑3 . 1.2.1 This part of ISO11137 does not detail specified requirements for designating a medical device as sterile. NOTE Attention is drawn to regional and national requirements for designating medical devices as “sterile.?? See, for example, EN556‑1 or ANSI/AAMIST67 . 1.2.2 This part of ISO11137 does not specify a quality management system for the control of all stages of production of medical devices. NOTE It is not a requirement of this part of ISO11137 to have a complete quality management system during manufacture, but the elements of a quality management system that are the minimum necessary to control the sterilization process are normatively referenced at appropriate places in the text (see, in particular, Clause4). Attention is drawn to the standards for quality management systems (see ISO13485 ) that control all stages of production of medical devices, including the sterilization process. Regional and national regulations for the provision of medical devices might require implementation of a complete quality management system and the assessment of that system by a third party. 1.2.3 This part of ISO11137 does not require that biological indicators be used for validation or monitoring of radiation sterilization, nor does it require that a pharmacopoeial test for sterility be carried out for product release. 1.2.4 This part of ISO11137 does not specify requirements for occupational safety associated with the design and operation of irradiation facilities. NOTE Attention is also drawn to the existence, in some countries, of regulations laying down safety requirements for occupational safety related to radiation. 1.2.5 This part of ISO11137 does not specify requirements for the sterilization of used or reprocessed devices.

    General Product Information - (Show below) - (Hide below)

    Committee CH/198
    Document Type Standard
    Product Note THIS STANDARD ALSO REFERS TO IAEA Safety Series No.107, HGB N43.10-2001, TS 11139:2006, AAMI TIR17:1997
    Publisher British Standards Institution
    Status Current
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective