• BS ISO 7507-1:2003

    Current The latest, up-to-date edition.

    Petroleum and liquid petroleum products. Calibration of vertical cylindrical tanks Strapping method

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  10-02-2004

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Precautions
    5 Equipment
    6 General requirements
    7 Circumference measurements
    8 Other measurements on tank shell plates
    9 Deadwood
    10 Tank bottoms
    11 Measurement of tilt
    12 Floating-roof tanks
    13 Recalibration
    14 Computation of tank capacity tables - General rules
    15 Form of tank capacity tables
    16 Computation of open capacity
    17 Construction of final tables
    Annex A (normative) Specification for equipment used in strapping
    Annex B (informative) Recommendations for monitoring,
            checking and verification of tank calibration
            and capacity table
    Annex C (informative) Tank calibration data and calculation sheet
    Annex D (informative) Tank calibration uncertainties
    Annex E (informative) Tank shell temperature determination
    Annex F (normative) Gauge tape temperature correction
    Annex G (informative) Expansion due to liquid head
    Annex H (normative) Expansion due to temperature
    Annex I (normative) Certificate of calibration
    Bibliography

    Abstract - (Show below) - (Hide below)

    Specifies method for the calibration of substantially vertical cylindrical tanks by measuring the tank using a strapping tape.

    Scope - (Show below) - (Hide below)

    1.1 This part of ISO 7507 specifies a method for the calibration of substantially vertical cylindrical tanks by measuring the tank using a strapping tape.

    1.2 This method is known as the “strapping method?? and is suitable for use as a working method, a reference method or a referee method.

    NOTE For the reference method, the number of strappings required will be specified in the standard which refers to this part of ISO 7507.

    1.3 The operation of strapping, the corrections to be made and the calculations leading to the compilation of the tank capacity table are described.

    1.4 This method does not apply to abnormally deformed, e.g. dented or non-circular, tanks.

    1.5 This method is suitable for tilted tanks with a deviation of up to 3 % from the vertical, provided that a correction for the measured tilt is applied in the calculations.

    General Product Information - (Show below) - (Hide below)

    Committee PTI/12
    Development Note Supersedes 02/121954 DC, BS 7723-1(1994) & BS 7723-6(1998) (02/2004)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 4269:2001 Petroleum and liquid petroleum products Tank calibration by liquid measurement Incremental method using volumetric meters
    ISO 4512:2000 Petroleum and liquid petroleum products Equipment for measurement of liquid levels in storage tanks Manual methods
    ISO 3675:1998 Crude petroleum and liquid petroleum products Laboratory determination of density Hydrometer method
    ISO 91-1:1992 Petroleum measurement tables Part 1: Tables based on reference temperatures of 15 degrees C and 60 degrees F
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications