    4 Technical requirements and specifications
       4.1 General requirements
       4.2 Presentation of equipment for testing purposes
       4.3 Mechanical and electrical design
       4.4 Declarations by the provider
       4.5 Auxiliary test equipment
       4.6 Interpretation of the measurement results
    5 Test conditions, power sources and ambient temperatures
       5.1 Normal and extreme test conditions
       5.2 Test power source
       5.3 Normal test conditions
       5.4 Extreme test conditions
    6 General conditions
       6.1 Normal test signals and test modulation
       6.2 Antennas
       6.3 Artificial antenna
       6.4 Test fixture for ULP-AMD, ULP-AMD-P and
            ULP-AMI-P devices
       6.5 Test fixture for ULP-AMI and ULP-BWD
       6.6 Test sites and general arrangements for
            radiated measurements
       6.7 Modes of operation of the transmitter
       6.8 Measuring receiver
    7 Measurement uncertainty
    8 Methods of measurement and limits for transmitter
       parameters
       8.1 Frequency error
       8.2 Emission bandwidth measurement
       8.3 Effective radiated power of the fundamental emission
       8.4 Spurious emissions
       8.5 Frequency stability under low voltage conditions
       8.6 Spectrum access based on low power and low duty cycle
    9 Methods of measurement and limits for receiver parameters
       9.1 Spurious radiation
    10 Requirements for spectrum access and measuring methods
       for monitoring systems using LBT and AFA
       10.1 Purpose
       10.2 LBT threshold power level
       10.3 Monitoring system bandwidth
       10.4 Monitoring system scan cycle time and minimum channel
            monitoring period
       10.5 Channel access based on ambient levels relative to the
            calculated access LBT threshold level, P[Th]
       10.6 Discontinuation of MEDS session if a silent period
            greater than or equal to 5 s occurs
       10.7 Use of pre-scanned alternate channel
    Annex A (normative): Radiated measurements
          A.1 Test sites and general arrangements for measurements
              involving the use of radiated fields
          A.2 Guidance on the use of radiation test sites
          A.3 Further optional alternative indoor test site using
              a fully anechoic chamber
    Annex B (normative): Technical performance of the spectrum analyser
    Annex C (informative): Bibliography
    History

    Abstract - (Show below) - (Hide below)

    Covers various individual devices which when operating together form a system operating as a Medical Data Service (MEDS) that provides medical practioners with therapeutic and/or diagnostic information used to provide improved medical treatment of a patient.

    General Product Information - (Show below) - (Hide below)

    Committee ERM TG30
    Document Type Standard
    Publisher European Telecommunications Standards Institute
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    TR 103 265 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); DEFINITION OF RADIO PARAMETERS
    TR 102 914 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ASPECTS AND IMPLICATIONS OF THE INCLUSION OF RECEIVER PARAMETERS WITHIN ETSI STANDARDS
    TR 103 088 : 1.3.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); USING THE ETSI EN 301 489 SERIES OF EMC STANDARDS
    SR 002 564 : 2.0.0 APPLICABILITY OF EXISTING ETSI AND ETSI/3GPP DELIVERABLES TO EHEALTH
    TR 102 655 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SYSTEM REFERENCE DOCUMENT; SHORT RANGE DEVICES (SRD); LOW POWER ACTIVE MEDICAL IMPLANTS (LP-AMI) OPERATING IN A 20 MHZ BAND WITHIN 2360 MHZ TO 3400 MHZ
    TR 102 137 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); USE OF RADIO FREQUENCY SPECTRUM BY EQUIPMENT MEETING ETSI STANDARDS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective