EN 50291-1:2018
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Gas detectors - Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 1: Test methods and performance requirements
27-04-2018
22-01-2021
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Design requirements
6 Test and performance requirements
7 Apparatus using radio links
8 User instructions
9 Packaging
Annex A (informative) - Extended stability
test - Sample protocol
Annex B (informative) - Calculation of the expected
battery service life
Annex C (informative) - Visual and audible fault
indication sequences
Annex D (informative) - A-deviations
Annex E (informative) - Test arrangement schematics
Annex F (informative) - Additional requirements for
units displaying low (warning) CO concentrations
Bibliography
This European Standard specifies general requirements for the construction, testing and performance of electrically operated carbon monoxide gas detection apparatus, designed for continuous operation in domestic premises. The objective is to detect defective fossil fuel or solid fuel appliances so that they can be repaired or replaced. The function of the standard is not to monitor low levels of CO for health purposes. (Annex F gives recommendations for units displaying low (warning) CO concentrations). The apparatus may be mains-powered or battery-powered. Such apparatus is intended to warn of an acute level of CO, enabling the occupant to react before being exposed to significant risk.Additional requirements for apparatus to be used in recreational vehicles and similar premises are specified in EN 50291-2.NOTE 1For caravan holiday homes EN 50291-1 applies.This European Standard specifies two types of apparatus, these are:-type A - to provide a visual and audible alarm and an executive action in the form of a transmittable output signal that can be used to actuate directly or indirectly a ventilation or other ancillary device;-type B - to provide a visual and audible alarm only.NOTE 2Both type A and type B apparatus can be interconnected.This European Standard excludes apparatus for:-the detection of combustible gases, other than carbon monoxide itself (see EN 50194-1);-the detection of CO in industrial installations (see EN 45544-1, EN 45544-2 and EN 45544-3) or commercial premises;-CO measurement for smoke and fire detection;-CO measurement in carparks and tunnels.NOTE 3See EN 50545-1.
| Committee |
CLC/TC 216
|
| DevelopmentNote |
Supersedes EN 50291. (05/2010)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Superseded
|
| Standards | Relationship |
| DIN EN 50291-1 : 2013 | Identical |
| VDE 0400-34-1 : 2013 | Identical |
| NF EN 50291-1 : 2010 AMD 1 2012 | Identical |
| I.S. EN 50291-1:2010 | Identical |
| NEN-EN 50291-1:2018/C1:2021 | Identical |
| NBN EN 50291-1 : 2010 AMD 1 2012 | Identical |
| NEN EN 50291-1 : 2010 AMD 1 2012 | Identical |
| BS EN 50291-1 : 2010 | Identical |
| CEI EN 50291-1:2018 | Identical |
| NF EN 50291-1:2018 | Identical |
| PN EN 50291-1 : 2010 AMD 1 2013 | Identical |
| PN EN 50291-1 : 2018 | Identical |
| DIN EN 50291-1 :2019-04 | Identical |
| SS-EN 50291-1:2018 | Identical |
| VDE 0400-34-1:2019-04 | Identical |
| CEI EN 50291-1:2021 | Identical |
| BS EN 50291-1:2018 | Equivalent |
| UNE-EN 50291-1:2018 | Identical |
| BS EN 50291-1:2018 | Identical |