• IEC TS 62462:2007

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Ultrasonics - Output Test - Guide for the maintenance of ultrasound physiotherapy systems

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  31-12-2021

    Language(s):  English

    Published date:  15-05-2007

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Testing regimes
    5 Performance testing
    Annex A (informative) - Rationale for testing
    Annex B (informative) - Guidance for testers
    Annex C (informative) - Quantitative relative ultrasonic
            output test using temperature rise
    Annex D (informative) - Quantitative relative ultrasonic
            output test using calorimetry
    Annex E (informative) - Qualitative test to assess changes
            of effective radiating area
    Annex F (informative) - Example of weekly test report
    Annex G (informative) - Example of annual test report
    Bibliography

    Abstract - (Show below) - (Hide below)

    The purpose of this technical specification is to establish standard methods for a qualitative check of the performance of ultrasound physiotherapy devices during their lifetime, and to provide guidance on calibration requirements and techniques.To ensure that the ultrasound physiotherapy equipment is in an appropriate condition for use, a regular quality check is necessary. This technical specification defines acceptance, weekly and annual checks. The acceptance test checks the delivery of the device and its performance at the start of its lifetime. The weekly check is a simple qualitative check of device operation. In the annual check, in addition to a qualitative check, a quantitative check is defined. Examples are provided of weekly and annual test reports. This report also gives guidance to the testers concerning the measurement of acoustic output. Annual testing is to be performed by a skilled tester, e.g. biomedical engineer, medical physicist, medical device service agent, commercial tester, test house, national measurement institute or manufacturer.

    General Product Information - (Show below) - (Hide below)

    Committee TC 87
    Development Note Stability Date: 2019. (07/2017)
    Document Type Technical Specification
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    08/30173423 DC : DRAFT JULY 2008 BS EN 60601-2-5 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-5: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ULTRASONIC PHYSIOTHERAPY EQUIPMENT
    I.S. EN 60601-2-5:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-5: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ULTRASONIC PHYSIOTHERAPY EQUIPMENT
    CSA C22.2 No. 60601.2.5:2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-5: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ULTRASONIC PHYSIOTHERAPY EQUIPMENT
    BS EN 60601-2-5:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
    CSA C22.2 No. 60601.2.5 : 2011 : R2016 MEDICAL ELECTRICAL EQUIPMENT - PART 2-5: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ULTRASONIC PHYSIOTHERAPY EQUIPMENT
    IEC 60601-2-5:2009 Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
    EN 60601-2-5:2015 Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60601-2-5:2009 Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
    IEC 61161:2013 Ultrasonics - Power measurement - Radiation force balances and performance requirements
    IEC 61689:2013 Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz
    IEC 60050-802:2011 International Electrotechnical Vocabulary (IEV) - Part 802: Ultrasonics
    IEC TR 62781:2012 Ultrasonics - Conditioning of water for ultrasonic measurements
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective