IEEE C37.20.2-2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
IEEE Standard for Metal-Clad Switchgear
13-01-2023
English
22-09-2015
1 Overview
2 Normative references
3 Definitions
4 Service conditions
5 Ratings
6 Tests
7 Construction
8 Application guide for MC switchgear
9 Guide for handling, storage, and installation
Annex A (informative) - Bibliography
Annex B (normative) - Guide for enclosure categories
and related requirements
Annex C (informative) - Partial discharge testing
Annex D (normative) - Voltage dividers
This standard covers metal-clad switchgear containing, but not limited to, such devices as power circuit breakers, other interrupting devices, switches, control, instrumentation and metering, and protective and regulating equipment.
Committee |
Switchgear
|
DevelopmentNote |
Supersedes IEEE DRAFT C37.20.2 (04/2001)
|
DocumentType |
Standard
|
ISBN |
978-0-7381-9943-6
|
Pages |
171
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
16/30337938 DC : 0 | BS EN 80005-1 - UTILITY CONNECTIONS IN PORT - HIGH VOLTAGE SHORE CONNECTION (HVSC) SYSTEMS - PART 1: GENERAL REQUIREMENTS |
BS IEC/IEEE 62271-37-013:2015 | High-voltage switchgear and controlgear Alternating-current generator circuit-breakers |
14/30257408 DC : 0 | BS IEC/IEEE 62271-37-013 ED 1.0 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 37-013: ALTERNATING-CURRENT GENERATOR CIRCUIT-BREAKERS |
CSA C22.2 No. 0.22 : 2011 : INC : UPD 1 : 2012 | EVALUATION METHODS FOR ARC RESISTANCE RATINGS OF ENCLOSED ELECTRICAL EQUIPMENT |
IEEE 400.1-2007 | IEEE Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Voltage |
IEEE 693-2005 | IEEE Recommended Practice for Seismic Design of Substations |
IEEE DRAFT 1147 : D8 2005 | GUIDE FOR THE REHABILITATION OF HYDROELECTRIC POWER PLANTS |
IEEE C37.23-2003 | IEEE Standard for Metal-Enclosed Bus |
IEEE 1566-2015 | IEEE Standard for Performance of Adjustable-Speed AC Drives Rated 375 kW and Larger |
MIL-DTL-32483 Base Document:2013 | Switchgear, Power, Hard-Mounted, Medium Voltage, Naval Shipboard |
TM 5-811-1 : V19950228 | ARMY TECHNICAL MANUAL - ELECTRICAL POWER SUPPLY AND DISTRIBUTION |
IEEE C37.23-2015 | IEEE Standard for Metal-Enclosed Bus |
IEEE 693-2018 | IEEE Recommended Practice for Seismic Design of Substations |
IEEE C37.81-2017 | IEEE Guide for Seismic Qualification of Class 1E Metal-Enclosed Power Switchgear Assemblies |
IEEE C37.121-2020 | IEEE Guide for Switchgear--Unit Substation--Requirements |
ANSI C37.22:1997 | AMERICAN NATIONAL STANDARD PREFERRED RATINGS AND RELATED REQUIRED CAPABLITIES FOR INDOOR AC MEDIUM VOLTAGE SWITCHES USED IN METAL-ENCLOSED SWITCHGEAR |
IEEE C37.20.7-2007 REDLINE | IEEE Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults |
07/30173659 DC : 0 | BS EN 62271-200 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEEE C37.010-1999 | IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
IEEE C37.302-2015 | IEEE Guide for Fault Current Limiter (FCL) Testing of FCLs Rated above 1000 V AC |
IEEE C37.81-1989 | IEEE Guide for Seismic Qualification of Class 1E Metal-Enclosed Power Switchgear Assemblies |
IEEE 45-7 : 2012 | RECOMMENDED PRACTICE FOR ELECTRICAL INSTALLATIONS ON SHIPBOARD - AC SWITCHBOARDS |
NEMA SG 10 : 2013 | GUIDE TO OSHA AND NFPA 70E SAFETY REQUIREMENTS WHEN SERVICING AND MAINTAINING MEDIUM-VOLTAGE SWITCHGEAR, CIRCUIT BREAKERS, AND MEDIUM-VOLTAGE CONTROLLERS RATED ABOVE 1000 V |
ANSI C37.57 : 1990 | SWITCHGEAR - METAL-ENCLOSED INTERRUPTER SWITCHGEAR ASSEMBLIES - CONFORMANCE TESTING |
NEMA SG 3 : 1995 | LOW-VOLTAGE POWER CIRCUIT BREAKERS |
ANSI C37.58 : 1990 | INDOOR AC MEDIUM-VOLTAGE SWITCHES FOR USE IN METAL-ENCLOSED SWITCHGEAR - CONFORMANCE TEST PROCEDURES |
ANSI C37.55 : 1989 | MEDIUM VOLTAGE METAL-CLAD ASSEMBLIES - CONFORMANCE TEST PROCEDURES |
ANSI C37.54 : 1996 | FOR INDOOR ALTERNATING CURRENT HIGH-VOLTAGE CIRCUIT BREAKERS APPLIED AS REMOVABLE ELEMENTS IN METAL-ENCLOSED SWITCHGEAR ASSEMBLIES - CONFORMANCE TEST PROCEDURES |
NEMA SG 5-1995 | POWER SWITCHGEAR ASSEMBLIES |
NEMA SG 7 : 1991 | MANUFACTURERS LABELS FOR SWITCHGEAR ASSEMBLIES |
IEEE C37.04-1999 | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers |
UFC 3-550-01 : CHANGE 1 | UNIFIED FACILITIES CRITERIA - EXTERIOR ELECTRICAL POWER DISTRIBUTION |
IEEE DRAFT C37.09 : D03F JAN 99 | TEST PROCEDURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS |
CSA C22.2 No. 0.22 : 2011 | EVALUATION METHODS FOR ARC RESISTANCE RATINGS OF ENCLOSED ELECTRICAL EQUIPMENT |
IEEE C37.34-1994 | IEEE Standard Test Code for High-Voltage Air Switches |
IEEE DRAFT C37.20.4 : 2001 | DRAFT STANDARD FOR INDOOR AC SWITCHES RATED ABOVE 1KV THROUGH 38KV FOR USE IN METAL-ENCLOSED SWITCHGEAR |
IEEE C37.20.6-2015 REDLINE | IEEE Standard for 4.76 kV to 38 kV Rated Ground and Test Devices Used in Enclosures |
IEEE C37.59-2007 | IEEE Standard Requirements for Conversion of Power Switchgear Equipment |
IEEE DRAFT C37.20.7 : 0 | TESTING METAL-ENCLOSED SWITCHGEAR RATED UP TO 38 KV FOR INTERNAL ARCING FAULTS |
CSA C22.2 No. 0.22 : 2011 : R2016 | EVALUATION METHODS FOR ARC RESISTANCE RATINGS OF ENCLOSED ELECTRICAL EQUIPMENT |
API 14F : 2008 : R2013 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) |
IEEE 3001.5-2013 | IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems |
BS ISO/IEC/IEEE 80005-1:2012 | Utility connections in port High Voltage Shore Connection (HVSC) Systems. General requirements |
C22.2 NO. 31-18 | Switchgear assemblies |
IEEE C37.10-2011 REDLINE | IEEE Guide for Investigation, Analysis, and Reporting of Power Circuit Breaker Failures |
IEEE C37.121-2012 | GUIDE FOR SWITCHGEAR - UNIT SUBSTATION - REQUIREMENTS |
IEEE DRAFT 693 : D9 2004 | SEISMIC DESIGN OF SUBSTATIONS |
API RP 14F:2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
IEEE 1147-2005 | IEEE Guide for the Rehabilitation of Hydroelectric Power Plants |
IEEE 45.3-2015 | IEEE Recommended Practice for Shipboard Electrical Installations -- Systems Engineering |
UL 1008A:2ED 2017-09-05 | Transfer Switch Equipment, Over 1000 Volts |
CSA C22.2 NO. 178.3:17 | Transfer switch equipment, over 1000 volts (Binational standard with UL 1008A) |
IEEE C37.82-1987 | IEEE Standard for the Qualification of Switchgear Assemblies for Class 1E Applications in Nuclear Power Generating Stations |
IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
IEEE C37.24-2003 | IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear |
IEEE 45.6-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing |
IEEE C37.121-2012 REDLINE | IEEE Guide for Switchgear - Unit Substation - Requirements |
IEEE 1247 : 2005 | INTERRUPTER SWITCHES FOR ALTERNATING CURRENT, RATED ABOVE 1000 V |
IEEE 1434-2014 | IEEE Guide for the Measurement of Partial Discharges in AC Electric Machinery |
IEEE C37.20.4-2013 REDLINE | IEEE Standard for Indoor AC Switches (1 kV to 38 kV) for Use in Metal-Enclosed Switchgear |
IEEE C37.37-1996 | IEEE Loading Guide for AC High-Voltage Air Switches (in Excess of 1000 V) |
IEEE 317-2013 REDLINE | IEEE Standard for Electric Penetration Assemblies in Containment Structures for Nuclear Power Generating Stations |
IEEE C37.09-1999 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
API 14FZ : 2013 | RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS |
API 14F REDLINE : 2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
IEC/ISO/IEEE 80005-1:2012 | Utility connections in port - Part 1: High Voltage Shore Connection (HVSC) Systems - General requirements |
IEEE C37.21-2005 | IEEE Standard for Control Switchboards |
PIP ELSSG12 : 2019 | DESIGN AND FABRICATION OF OUTDOOR ENCLOSURES FOR MOTOR CONTROLLERS AND SWITCHGEAR |
PIP ELSSG02 : 2017 | DESIGN AND FABRICATION OF MEDIUM-VOLTAGE METAL-CLAD SWITCHGEAR ABOVE 1000 V TO 38 KV |
ISA 77.20 : 1993 : R2005 | FOSSIL FUEL POWER PLANT SIMULATORS - FUNCTIONAL REQUIREMENTS |
IEEE C37.04-2018 | IEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V |
IEEE C37.09-2018 | IEEE Standard Test Procedures for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V |
IEEE C37.010-2016 | IEEE Application Guide for AC High-Voltage Circuit Breakers > 1000 Vac Rated on a Symmetrical Current Basis |
IEEE 3004.11-2019 | IEEE Recommended Practice for Bus and Switchgear Protection in Industrial and Commercial Power Systems |
IEEE C37.82-2017 | IEEE Standard for the Qualification of Switchgear Assemblies for Class 1E Applications in Nuclear Power Generating Stations |
IEEE C37.20.9-2019 | IEEE Standard for Metal-Enclosed Switchgear Rated 1 kV to 52 kV Incorporating Gas Insulating Systems |
IEEE C37.24-2017 | IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear |
IEEE C37.20.7-2017 | IEEE Guide for Testing Switchgear Rated Up to 52 kV for Internal Arcing Faults |
PIP ELSSG03 : 2016 | DESIGN AND FABRICATION OF MEDIUM VOLTAGE METAL-ENCLOSED LOAD INTERRUPTER SWITCHGEAR |
PIP ELSGS07 : 2009 | DESIGN AND FABRICATION OF HIGH-RESISTANCE GROUNDING SYSTEM (1 TO 5 KV) |
PIP ELSPF01 : 2016 | MEDIUM-VOLTAGE METAL-ENCLOSED POWER FACTOR CORRECTION CAPACITOR SPECIFICATION FROM 2.4 KV TO 35 KV |
ISA 77.20 :1993 | FOSSIL FUEL POWER PLANT SIMULATORS - FUNCTIONAL REQUIREMENTS |
PIP ELSSG12 : 2018 | DESIGN AND FABRICATION OF OUTDOOR ENCLOSURES FOR MOTOR CONTROLLERS AND SWITCHGEAR |
PIP ELSSG12 : 2012 | DESIGN AND FABRICATION OF OUTDOOR ENCLOSURES FOR MOTOR CONTROLLERS AND SWITCHGEAR |
IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEEE C37.013-1997 | IEEE Standard for AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C37.20.6-2015 REDLINE | IEEE Standard for 4.76 kV to 38 kV Rated Ground and Test Devices Used in Enclosures |
IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
ASTM G 21 : 2015 : REDLINE | Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi |
NEMA WC 70 : 2009 | POWER CABLES RATED 2000 VOLTS OR LESS FOR THE DISTRIBUTION OF ELECTRICAL ENERGY |
IEEE C37.82-1987 | IEEE Standard for the Qualification of Switchgear Assemblies for Class 1E Applications in Nuclear Power Generating Stations |
IEEE 344-2013 | IEEE Standard for Seismic Qualification of Equipment for Nuclear Power Generating Stations |
IEEE C37.81-1989 | IEEE Guide for Seismic Qualification of Class 1E Metal-Enclosed Power Switchgear Assemblies |
IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
ANSI C37.55 : 1989 | MEDIUM VOLTAGE METAL-CLAD ASSEMBLIES - CONFORMANCE TEST PROCEDURES |
ASTM D 2303 : 2013 | Standard Test Methods for Liquid-Contaminant, Inclined-Plane Tracking and Erosion of Insulating Materials |
IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) |
IEEE C37.20.4-2013 REDLINE | IEEE Standard for Indoor AC Switches (1 kV to 38 kV) for Use in Metal-Enclosed Switchgear |
IEEE C37.010-1999 | IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C37.11-2014 | IEEE Standard Requirements for Electrical Control for AC High-Voltage (>1000 V) Circuit Breakers |
IEC 61243-5:1997 | Live working - Voltage detectors - Part 5: Voltage detecting systems (VDS) |
IEEE C37.40-2003 | IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories |
ANSI C37.54 : 1996 | FOR INDOOR ALTERNATING CURRENT HIGH-VOLTAGE CIRCUIT BREAKERS APPLIED AS REMOVABLE ELEMENTS IN METAL-ENCLOSED SWITCHGEAR ASSEMBLIES - CONFORMANCE TEST PROCEDURES |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
IEEE C37.90.2:2004 | WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS |
IEC 62271-206:2011 | High-voltage switchgear and controlgear - Part 206: Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kV |
IEEE C37.09-1999 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
IEEE C37.90.1-2012 | IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus |
IEEE C37.24-2003 | IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear |
UL 1332:5ED 2016-02-12 | Organic Coatings for Steel Enclosures for Outdoor Use Electrical Equipment |
NEMA CC1 : 2009(R2015) | ELECTRIC POWER CONNECTORS FOR SUBSTATIONS |
NEMA LI 1 : 1998(R2011) | INDUSTRIAL LAMINATED THERMOSETTING PRODUCTS |
NEMA 260:1996(R2004) | Safety Labels for Pad-Mounted Switchgear and Transformers Sited in Public Areas |
IEEE C37.41-2008 REDLINE | IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices |
IEEE C37.04-1999 | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers |
IEEE C37.06-2009 | IEEE Standard for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis--Preferred Ratings and Related Required Capabilities for Voltages Above 1000 V |
IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.